DOI QR코드

DOI QR Code

Prediction of residual chlorine using two-component second-order decay model in water distribution network

이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용

  • Kim, Young Hyo (Department of Environmental Engineering, Konkuk University) ;
  • Kweon, Ji Hyang (Department of Environmental Engineering, Konkuk University) ;
  • Kim, Doo Il (Department of Civil and Environmental Engineering Dankook University)
  • Received : 2014.03.14
  • Accepted : 2014.05.30
  • Published : 2014.06.15

Abstract

It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

Keywords

References

  1. Nation al waterworks information system, water distribution statics, (2011) http://www.waternow.go.kr/openPage.do?OPENCODE=PG_STAT03
  2. Seoul city, (2013), Decreasing disinfection odor of tap water in Seoul with new disinfection method, http://spp.seoul.go.kr/main/news/news_report.jsp?search_boardId =18232&act=VIEW&boardId=18232.Searching date : 2013.12.01
  3. Hyung -Jae Choi, (2006), Prediction of residual chlorine concentration in the water distribution pipes using the MIKE NET model, Master's thesis, pp. 19-20.
  4. Micistry of environment,(2013), Environmental Act 503, 2013.3.23.,Amended, Water Distribution Regulations, Article 22-2.
  5. Clark R ,. (1998) Chlorine demand and TTHM Formation kinetics: a second - order model, Journal of water pollujtion control, 56, 170-173.
  6. Gotoh, K., (1988) Residual chlorine concentration decreasing rate coefficient for various pipe materials, In: Proceedings of the 17th IWSA water supply Conference, vol. 7.
  7. Haas, C.N., Karra, S.B.,(1984) kinetics of waste chlorine demand exertion., Jour. Water Pollution Control Fedn., 56(2), pp.170-173.
  8. Jadan- Hecart, A., El Mother, A., Stitou, M., Bouillot, P., and Legube, B. (1992) The chlorine demand of a treated water, Water Research, 26 (8), pp. 1073-1084 https://doi.org/10.1016/0043-1354(92)90143-R
  9. J. J. H uang, E.A. McBean,(2007) Using Bayesian statistics to estimate the coefficients of a two- component second-order chlorine bulk decay model for a water distribution system., water research, 41 (2), pp.278-294.
  10. Kohpa ei, A. J., Sathasivan, A.(2011) Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development, Chemical Engineering journal, 171, pp.232-241. https://doi.org/10.1016/j.cej.2011.03.034
  11. Powell, J.C., West, R.J., Hallam, B.N., Forster, F.C., Simms, J.(2000) Performance of various kinectic models for chlorine decay, J. water Resour. Plng. And Mgmt, ACSE, Jan/Feb. 126 (1), pp.13-20 https://doi.org/10.1061/(ASCE)0733-9496(2000)126:1(13)
  12. Sharp, W.W., Preffer, J.,Morgan, M. (1991) Insitu chlorine decay rate testing, Proceeding of the Water Quality Modeling in Distribution Systems Conference, AWWA Research Foundation, Denver, CO.
  13. Singer P.C., (1999), Humic Substances as precursors for potentially harmful disinfection by-products, Water Science Technology, 40 (9), pp.25-30.
  14. Rossma n, A.L., Clark, R.M., and Grayman, W.M. (1994) Modeling chlorine residuals in drinking water distribution systems, J. Environmental engineering. ASCE, 120 (4), pp.803-820 https://doi.org/10.1061/(ASCE)0733-9372(1994)120:4(803)