DOI QR코드

DOI QR Code

Unusual Migration of Kirschner's Wire into Intervertebral Foramen after Lateral Clavicle Fracture Fixation - A Case Report

  • Lee, Jin-Ho (Department of Orthopaedic Surgery, Chonnam National University College of Medicine) ;
  • Chung, Jae-Yoon (Department of Orthopaedic Surgery, Chonnam National University College of Medicine) ;
  • Kim, Myung-Sun (Department of Orthopaedic Surgery, Chonnam National University College of Medicine)
  • 투고 : 2014.02.21
  • 심사 : 2014.04.07
  • 발행 : 2014.06.30

초록

The migration of metallic devices such as Kirschner's wire (K-wire) from the shoulder is a well-recognized and significant complication of operation, the wire ending up in the lungs, the heart, the esophagus, the aorta or the subclavian artery. However, spinal migration is very rare. We report the case of a 72-year-old female patient with K-wire migration into the C7-T1 intervertebral foramen, 2 months after surgery for a lateral end fracture of left clavicle.

키워드

참고문헌

  1. Lyons FA, Rockwood CA Jr. Migration of pins used in operations on the shoulder. J Bone Joint Surg Am. 1990;72(8):1262-7.
  2. Mazet R. Migration of a Kirschner-wire from the shoulder region into the lung. Report of two cases. J Bone Joint Surg. 1943;25(2):477-83.
  3. Anic D, Brida V, Jelic I, Orlić D. The cardiac migration of a Kirschner wire. A case report. Tex Heart Inst J. 1997;24(4):359-61.
  4. Chou NS, Wu MH, Chan CS, Lai WW, Lin MY. Intrathoracic migration of Kirschner wires. J Formos Med Assoc. 1994;93(11-12):974-6.
  5. Demaria R, Picard E, Bodino M, et al. Migration of a clavicular bone wire acutely perforating the ascending aorta. Presse Med. 1998;27(21):1013.
  6. Brade A, Hippe P. Migration of Kirschner wire following osteosyntheses of the hip (author's transl). Z Orthop Ihre Grenzgeb. 1981;119(1):80-4. https://doi.org/10.1055/s-2008-1051426
  7. Rajesh PB, Nair KK. Unusual migration of a Kirschner wire. Eur J Cardiothorac Surg. 1991;5(3):164. https://doi.org/10.1016/1010-7940(91)90216-7
  8. Regel JP, Pospiech J, Aalders TA, Ruchholtz S. Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation. Neurosurg Rev. 2002;25(1-2):110-2. https://doi.org/10.1007/s101430100186
  9. Kumar P, Godbole R, Rees GM, Sarkar P. Intrathoracic migration of a Kirschner wire. J R Soc Med. 2002;95(4):198-9. https://doi.org/10.1258/jrsm.95.4.198
  10. Conzen M, Sollmann H. Displacement of materials in the cervical spinal canal following clavicular fixation as a late complication. Unfallchirurg. 1986;89(1):47-8.

피인용 문헌

  1. Kirschner Wire Migration into SpinaL Canal after Acromioclavicular Joint Fixation (Literature Review and Clinical Case) vol.24, pp.4, 2018, https://doi.org/10.21823/2311-2905-2018-24-4-121-128