Abstract

In a single-phase grid-connected power system consisting of a dc-dc converter and a dc-ac converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains double-fundamental frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new double-fundamental current reduction-scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small-signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

Keywords

References

  1. Mohamed El-Ashry, "Renewable Energy Policy Network for the 21st Century," Renewables global status report, REN21, 2009.
  2. John J. Conti, Glen E, Sweetnam, "International Energy Outlook 2009," Energy Information Administration, Official Energy statistics from the U.S. Government, 2009. Rep. DOE/EIA-0484(2009), 2009.
  3. F. Shinjo, K. Wada, and T. Shimizu, "A single-phase grid-connected inverter with a power decoupling function," in Proc. IEEE Power Electronics Specialists Conference, pp. 1245-1249, Jun. 2007.
  4. T. Shimizu, K. Wada, and N. Nakamura, "Flyback-type single-phase utility interactive inverter with power pulsation decoupling on the dc input for an ac photovoltaic module system," IEEE Trans. Power Electron., Vol. 21, No. 5, pp. 1264-1272, Sept. 2006. https://doi.org/10.1109/TPEL.2006.880247
  5. S. B. Kjaer and F. Blaabjerg, "Design optimization of a single phase inverter for photovoltaic applications," in Proc. IEEE 34th Power Electronics Specialist Conference 2003, pp. 1183-1190, Jun. 2003.
  6. J. G. Lee, J. W. Choi, "DC link Ripple Voltage Compensation of a Single-phase Grid-Connected PV System," The Transactions of the Korean Institute of Power Electronics, Vol. 17, No. 5, pp. 377-387, Oct. 2012. https://doi.org/10.6113/TKPE.2012.17.5.377
  7. H. S. An, W. J. Lee, B. H. Mun, I. K. Park, S. Y. Jung, Y. R. Kim., H. J. Cha, "Experiment of Single-phase Grid Connected Battery Charger," The Transactions of the Korean Institute of Power Electronics, Vol. 18, No. 1, pp. 84-90, Feb. 2013. https://doi.org/10.6113/TKPE.2013.18.1.84
  8. S. K. Mazumder, R. K. Burra, and K. Acharya, "A ripple-mitigating and energy-efficient fuel cell power conditioning system," IEEE Trans. Power Electron., Vol. 22, No. 4, pp. 1437-1452, Jul. 2007. https://doi.org/10.1109/TPEL.2007.900598
  9. J.-M. Kwon, E.-H. Kim, B.-H. Kwon, and K.-H. Nam, "High efficiency fuel cell power conditioning system with input current ripple reduction," IEEE Trans. Industrial Electronics, Vol. 56, No. 3, pp. 826-834, Mar. 2009. https://doi.org/10.1109/TIE.2008.2004393
  10. C. Liu and J.-S. Lai, "Low frequency current ripple reduction technique with active control in a fuel cell power system with inverter load," IEEE Trans. Power Electronics, Vol. 22, No. 4, pp. 1429-1436, Jul. 2007. https://doi.org/10.1109/TPEL.2007.900594
  11. V. Voperian, "Simplified analysis of PWM converters using the model of the PWM switch, continuous conduction mode," IEEE Trans. Aerospace and Electronics Systems, Vol. 26, No. 3, pp. 490-496, May 1990. https://doi.org/10.1109/7.106126

Cited by

  1. Reducing Common-Mode Voltage of Three-Phase VSIs using the Predictive Current Control Method based on Reference Voltage vol.15, pp.3, 2015, https://doi.org/10.6113/JPE.2015.15.3.712