DOI QR코드

DOI QR Code

Inner Evaporative Cooling Wind Power Generator with Non-overlapping Concentrated Windings

  • Li, Wang (Key Laboratory of Wind Energy Utilization, Institute of Electrical Engineering, Chinese Academy of Sciences) ;
  • Wang, Haifeng (Key Laboratory of Wind Energy Utilization, Institute of Electrical Engineering, Chinese Academy of Sciences)
  • 투고 : 2013.10.14
  • 심사 : 2013.11.13
  • 발행 : 2014.03.01

초록

As the space of the wind power generator stator end is limited, it is difficult for us to place the inner evaporative cooling system in it. We use the non-overlapping concentrated windings scheme to solve the placing and cooling problem. The characteristic of a 5MW direct-driven permanent magnet generator with non-overlapping concentrated windings were analyzed under no-load, rating-load and short-circuit by (Finite Element Method) FEM for verification of design. We studied the connection methods of the stator windings and designed the end connection member. The heat dissipation of the stator end was simulated by FEM, the result showed that the end cooling could satisfy the wind generator operation needs. These results show that the direct-driven permanent magnet wind power generators with non-overlapping concentrated windings and inner evaporative cooling system can solve the cooling problem of wind power generator, and obtain good performance at the same time.

키워드

참고문헌

  1. Ruan Lin, "The Basic Theory Research of the Inner Evaporative Cooing System for the Large Hydro-Generator and the Simulation of the CLSC System," Beijing: Institute of Electrical Engineering Chinese Academy of Science, 2004.
  2. Zhang Yue, Wang Fengxiang, "Analyzing Characteristic of the Permanent Magnet Directly Driven Wind Power Generators," Electric Machines And Control, 2009, 13(1): 78-82.
  3. Ki-Chan Kim, Seung-Bin Lim, Ki-Bong Jang, Sung-Gu Lee, Ju Lee, Yeoung-Gyu Son, Young-Kil Yeo, Soo-Hyun Baek, "Analysis on the Direct-Driven High Power Permanent Magnet Generator for Wind Turbine," ICEMS, Nanjing, 2005.
  4. Tang Renyuan, "Modern Permanent Magnet Motor Theory and Design," Beijing: Mechanical Industry Press, 1997.
  5. Zhu Deming Qiu Xin, Wang Huizhen, Yan yangon, "Nooverlapped concentrated winding factor effects on harmonic suppression of electric potential," Journal of electrical and control, 2008, 12 (6) : 650-654.
  6. Yue Zhang, Fengxiang Wang, "Choice of Pole-Slot Number Combination for PM Generator Direct-Driven by Wind Turbine," Power System Technology and IEEE Power India Conference, 2008.
  7. Chen Yiguang, "Pole and slot combination and magnetomotive force of permanent magnet synchronism generator with concentrated windings," 11th national academic exchange meeting permanent magnet motor, 2011.
  8. Yang Shiming, Tao WenQuan, "Heat transfer," Beijing: Higher Education Press, 2006,197-457.