Abstract

The objectives of this study was to evaluate the validity of 3D digital models made from blue LED dental scanner. Twenty same cases of stone models and 3d digital models were manufactured for this study. Intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) were measured for evaluation of validity. The nonparametric Wilcoxon rank sum test was used for statistical analysis (${\alpha}$=0.05). Although stone models showed larger than digital models in all measured distances(p<0.05), none exceeded the clinically acceptable range.

본 연구의 목적은 블루 LED 기반의 치과용 스캐너를 이용하여 제작된 3차원 디지털 모형의 정확도를 평가하는 것이다. 본 연구를 위하여 20개의 동일한 석고 모형 제작 후 블루 LED기반의 치과용 스캐너를 이용하여 석고 모형과 동일한 20개의 3차원 디지털 모형을 제작하였다. 정확도를 평가하기 위해 두 집단의 모형을 대상으로 6개의 계측 거리를 지정한 후 측정하였다. 통계분석은 비모수 검정법인 윌콕슨 순위 합 검정법을 이용하여 비교 분석하였다(제1종 오류수준=0.05). 비록 모든 부위에서 디지털 모형이 석고 모형보다 작은 것으로 분석되었으나(p<0.05), 임상적 허용 수치를 벗어나지 않았다.

Keywords

References

  1. T. Miyazaki, Y. Hotta, J. Kunji, S. Kuriyama, Y. Tamaki, "A review of dental CAD/CAM: current status and future perspectives from 20 years of experience", Dental Materials Journal, Vol. 28, No. 1, pp. 44-56, 2009. DOI: http://dx.doi.org/10.4012/dmj.28.44
  2. K. J. Anusavice, "Phillips' science of dental materials. 11th ed", pp. 621-654, Philadelphia: W. B. Saunders, 2003.
  3. G. J. Christensen, "Impressions are changing: deciding on conventional, digital of digital plus in-office milling", Journal of the American Dental Association, Vol. 140, No. 6, pp. 1301-1304, 2009. DOI: http://dx.doi.org/10.14219/jada.archive.2009.0054
  4. K. B. May, M. M. Russel, M. E. Razzoog, B. R. Lang, "Precision of fit: the Procera AllCeram crown", Journal of Prosthetic Dentistry, Vol. 80, No. 2, pp. 394-404, 1993. DOI: http://dx.doi.org/10.1016/S0022-3913(98)70002-2
  5. Dental CAD-CAM eshop, Idenrica Blue Led information, Germany, Available From: http://www.dentalcadcameshop. com/Identica-Blue-Led, accessed on January 6, 2014.
  6. T. Kuroda, N. Motohashi, R. Tominaga, K. Iwata, "Three-dimensional dental cast analyzing system using laser scanning", American Journal of Orthodontics, Vol. 110, No. 1, pp. 365-369, 1996. DOI: http://dx.doi.org/10.1016/S0889-5406(96)70036-7
  7. N. Motohashi, T. Kuroda, "A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery", European Journal of Orthodontics, Vol. 21, No. 3, pp. 263-374, 1999. DOI: http://dx.doi.org/10.1093/ejo/21.3.263
  8. K. B. Kim, G. T. Lee, J. H. Kim, "Comparison of the accuracy of digital models made from white light scanner by scanning method", Journal of Korean Society of Dental Hygiene, Vol. 12, No. 6, pp. 1082-1089, 2012. DOI: http://dx.doi.org/10.13065/jksdh.2012.12.6.1082
  9. K. B. Kim, S. J. Kim, J. H. Kim, J. H. Kim, "An evaluation of validity of three dimensional digital model fabricated by dental scannable stone", The Journal of Korean Academy of Dental Technology, Vol. 35, No. 1, 2013. https://doi.org/10.14347/kadt.2013.35.1.029
  10. B. Creed, H. K. Chung, D. E. Jeryl, J. X. James, P. Robert, "A comparison of the accuracy of linear measurements obtained from cone beam computerized tomography images and digital models", Seminars in Orthodontics, Vol. 17, No. 1, pp. 49-56, 2011. DOI: http://dx.doi.org/10.1053/j.sodo.2010.08.010
  11. S. I. Bak, "The comparison between manual and 3D-digital measurement in dental cast measurements according to the degree of crowding", Korea University Graduate School of Clinical Dentistry, Department of Orthodontics, Maters degree, 2006.
  12. M. N. Lowey, "The development of a new method of cephalometric and study cast mensuration with a computer controlled, video image capture system. Part II: study cast mensuration", Vol. 20, No. 4, pp. 315-331, 1993. https://doi.org/10.1179/bjo.20.4.315
  13. M. Mayers, A. S. Firestone, R. Rashid, K. W. Vig, "Comparison of peer assessment rating (PAR) index scores of plaster and computer-based digital models", American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 128, No. 4, pp. 431-434, 2005. DOI: http://dx.doi.org/10.1016/j.ajodo.2004.04.035
  14. M. L. Quimby, K. W. Vig, R. G. Rashid, A. R. Firestone, "The accuracy and reliability of measurements made on computer-based digital models", The Angle Orthodontist, Vol. 74, No. 3, pp. 298-303, 2004.
  15. P. A. Costalos, K. Sarraf, T. J. Cangialosi, S. Efstratiadis, "Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts", American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 128, No. 5, pp. 624-629, 2005. DOI: http://dx.doi.org/10.1016/j.ajodo.2004.08.017
  16. J. Asquith, T. Gillgrass, and P. Mossey, "Three-dimensional imaging of orthodontic models: a pilot study", European Journal of Orthodontics, Vol. 29, No. 5, pp. 517-522, 2007. DOI: http://dx.doi.org/10.1093/ejo/cjm044
  17. M. Santoro, S. Galkin, M. Teredesai, O. F. Nicolay, T. J. Cangialosi, "Comparison of measurements made on digital and plaster models", American Journal of Orthodontics and Dentofacial Orthopedics, Vol. 124, No. 1, pp. 101-105, 2003. DOI: http://dx.doi.org/10.1016/S0889-5406(03)00152-5
  18. O. Zilberman, J. A. Huggare, K. A. Parikakis, "Evaluation of the validity of tooth size and arch width measurements using conventional and three - dimensional virtual orthodontic models", The Angle Orthodontist, Vol. 73, No. 3, pp. 301-306, 2003.
  19. H. J. Moon, "State of education on the use of oral hygiene supplies among dental prosthesis mounted", Journal of the Korea Academia- Industrial Cooperation Society, Vol. 12, No. 12, pp. 5648-5654, 2011. DOI: http://dx.doi.org/10.5762/KAIS.2011.12.12.5648