References
- Ahmad, S. and Ansari, E. (2009), "Response of transmission towers subjected to tornado loads", Proceedings of the 7 th Asia-Pacific Conference on Wind Engineering, Taipei, Taiwan, November.
- American Meteorological Society (2000), Glossary of Meteorology, AMS, Boston, Massachusetts, U.S.A.
- American Society of Civil Engineers (ASCE) (2000), ASCE Standard 10-97, Design of Latticed Steel Transmission Structures, New York, U.S.A.
- American Society of Civil Engineers (ASCE) (1991), ASCE Manuals and Reports on Engineering Practice No. 74, Guidelines for electrical transmission line structural loading, Reston, Virginia, U.S.A.
- American Society of Civil Engineers (ASCE) (2005), ASCE Manuals and Reports on Engineering Practice No. 74 draft revision, Guidelines for electrical transmission line structural loading, Reston, Virginia, U.S.A.
- American Society of Civil Engineers (ASCE) (2010), ASCE Manuals and Reports on Engineering Practice No. 74, Guidelines for electrical transmission line structural loading third edition, Reston, Virginia, U.S.A.
- Behncke, R., White, H. and Milford, R. (1994), "High intensity wind and relative reliability based loads for transmission line design", Proceedings of the International Conference on Large High Voltage Electric Systems, Paris, France.
- Canadian Standards Association (CSA) (1976), CAN/CSA-C22.3 No.1, Overhead Systems, Montreal.
- CIGRE, (International Council on Large Electric Systems) (2009), Overhead line design guidelines for mittigation of severe wind storm damage (SC B2.39), Committee Draft, Paris, France.
- Computer and Structures Inc. (2008), CSI:SAP2000 Analysis Reference Manual, Computer and Structures Inc., Berkeley, California, USA.
- Darwish, M.M., El Damatty, A.A. and Hangan, H. (2010), "Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading", Wind Struct., 13(4), 327-347. https://doi.org/10.12989/was.2010.13.4.327
- Dempsey, D. and White H. (1996), "Winds wreak havoc on lines", Transmission Distribution World, 48(6), 32-37.
- Fluent Inc. (2005), Fluent 6.2 User's Guide, Fluent Inc., Lebanon.
- Fujita, T. (1981), "Tornadoes and downbursts in the context of generalized planetary scales", J. Atmos. Sci., 38(8), 1511-1534. https://doi.org/10.1175/1520-0469(1981)038<1511:TADITC>2.0.CO;2
- Hamada, A., El Damatty, A.A., Hangan, H. and Shehata, A.Y. (2010), "Finite element modelling of transmission line structures under tornado wind loading", Wind Struct., 13(5), 451-469. https://doi.org/10.12989/was.2010.13.5.451
- Hamada, A. and El Damatty, A.A. (2011), "Behaviour of guyed transmission line structures under tornado wind loading", Comput. Struct., 89(11-12), 986-1003. https://doi.org/10.1016/j.compstruc.2011.01.015
- Hangan, H. and Kim, J. (2008), "Swirl ratio effects on tornado vortices in relation to the Fujita scale", Wind Struct.,11(4), 291-302. https://doi.org/10.12989/was.2008.11.4.291
- Ishac, M. and White, H. (1995), "Effect of tornado loads on transmission lines", IEEE T. Power Deliver., 10, 445-451. https://doi.org/10.1109/61.368368
- Lahey Computer Systems Inc. (1999), LF Fortran Express User's Guide, Lahey Computer Systems, Inc., Incline Village, Nevada, USA.
- Langlois, S. (2007), Design of overhead transmission lines subject to localized high intensity wind, Master of Engineering Thesis, McGill University, Montreal.
- Lee, W.C. and Wurman, J. (2005), "Diagnosed three-dimensional axisymmetric structure of the Mulhall tornado on 3 May 1999", J. Atmos. Sci., 62, 2373-2393. https://doi.org/10.1175/JAS3489.1
- Matheson, M.J. and Holmes, J.D. (1981), "Simulation of the dynamic response of transmission lines in strong winds", Eng. Strucut., 3(2), 105-110. https://doi.org/10.1016/0141-0296(81)90036-5
- McCarthy, P. and Melsness, M. (1996), Severe weather elements associated with September 5, 1996 hydro tower failures near Grosse Isle, Manitoba, Canada, Manitoba Environmental Service Centre, Environment Canada.
- National Research Council of Canada (NRCC) (1990), Supplement to the National Building Code of Canada, Ottawa.
- Sarkar, P., Haan, F., Gallus, W. Jr., Kuai, Le. and Wurman, J., (2005), "Velocity measurements in a laboratory tornado simulator and their comparison with numerical and full-scale data", Proceedings of the 37th Joint Meeting Panel on Wind and Seismic Effects (UJNR), Tsukuba, Japan, May.
- Savory, E., Parke, G.A., Zeinoddini, M., Toy, N. and Disney, P. (2001), "Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower", Eng. Struct., 23(4), 365-375. https://doi.org/10.1016/S0141-0296(00)00045-6
- Shehata, A.Y., El Damatty, A.A. and Savory, E. (2005), "Finite element modelling of transmission line under downburst wind loading", Finite Elem. Anal. Des., 42(1), 71-89. https://doi.org/10.1016/j.finel.2005.05.005
- Wen, Y.K. (1975), "Dynamic tornadic wind loads on tall buildings", J. Struct. Eng. - ASCE, 101(1), 169-185.
Cited by
- A simplified method for estimating fundamental periods of pylons in overhead electricity transmission systems vol.19, pp.2, 2014, https://doi.org/10.12989/eas.2020.19.2.119