DOI QR코드

DOI QR Code

A Study on the Development of BIPV Module Equipped with Vacuum Glass for Improved Thermal Performance

단열성능 개선을 위한 진공유리가 부착된 BIPV Module 개발에 관한 연구

  • Eom, Jae-Yong (Department of Architecture Engineering, Graduate School of Inha University) ;
  • Lee, Hyun-Soo (Department of Architecture Engineering, Graduate School of Inha University) ;
  • Suh, Seung-Jik (Department of Architecture Engineering, Inha University)
  • 엄재용 (인하대학교 건축공학과 대학원) ;
  • 이현수 (인하대학교 건축공학과 대학원) ;
  • 서승직 (인하대학교 건축공학과)
  • Received : 2014.01.13
  • Accepted : 2014.04.21
  • Published : 2014.04.30

Abstract

The main purpose of this paper is to develop the new BIPV module equipped with vacuum glass. Beacuse BIPV module has a function of architectural materials, thermal and PV performance should be simultaneously evaluated. To improve the thermal performance of BIPV module, this study developed BIPV module equipped with a vacuum glass. Those BIPV module was tested with a variety of encapsulants. The results are as follows. When a vacuum glass is laminated with EVA or PVB, it was broken. The reason seems to be bending by unbalance of heat expansion with center and edge of vacuum glass. In case of lamination with resin, there is no breakage and no bending of vacuum glass. Because production was conducted in low pressure & low temperature conditions. And it was also found that vacuum glass does not interfere with the UV curing process.

Keywords

References

  1. Ministry of Knowledge Economy, New Renewable Energy White paper, 2012
  2. The Regulation of Building facilities, The21th, The table of Thermal transmittance whichis part of Related region's building)
  3. LBNL, Therm 7/Window 7 NFRC Simulation Manual, LBNL 2014
  4. Lee, Jin-Seob etal., Corre;atopn Effect of Lamination Condition and Bubble in Photovoltaic Module Manufacturing Process, KSES Spring Annual Conference presentation file(2007-04)
  5. Won, Jong-Seo etal., The Condensation Risk Assessment of Vacuum Multi-Layer Glass and Triple Glass using the Temperature difference Ratio, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 11(2013), pp. 573-577. https://doi.org/10.6110/KJACR.2013.25.11.573
  6. Song Su-Bin etal., Insulation Performance and Building Energy Saving Effect of Vacuum Insulation Glass, KSES Fall Annual Conference presentation file, Vol. 32, No. 2, pp. 139-142, 2012.
  7. Kim, Ha-Ryeon etal., Analysis on the Season Characteristics of Glass-Glass BIPV Module accroding to vatious Types of the Backside Glass, KSES Fall Annual Conference presentation file, Vol. 30, No. 2, 2010.
  8. The test report form KFPA 2010-683

Cited by

  1. 사례연구를 통한 DSC에 의한 BIPV 가능성 분석 연구 vol.16, pp.2, 2014, https://doi.org/10.7743/kisee.2017.16.2.054