DOI QR코드

DOI QR Code

컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera

  • 박종원 (경일대학교 첨단의료기학과)
  • Park, Jongwon (Department of High-tech. Medical System, Kyungil University)
  • 투고 : 2013.12.06
  • 심사 : 2014.02.19
  • 발행 : 2014.02.28

초록

Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

키워드

참고문헌

  1. Plotz CM and Singer JM, "The latex fixation test. Application to the serologic diagnosis of rheumatoid arthritis," Am J Med, vol. 21, no. 6, pp. 888-892, 1956. https://doi.org/10.1016/0002-9343(56)90103-6
  2. Posthuma-Trumpie GA, Korf J and van Amerongen A, "Lateral flow (immuno) assay: its strengths, weaknesses, opportunities and threats. A literature survey," Anal Bioanal Chem, vol. 393, no. 2, pp. 569-582, 2009. https://doi.org/10.1007/s00216-008-2287-2
  3. Wong R and Tse H, Lateral Flow Immunoassay, New York, USA: Humana Press, 2010, pp. 3-5.
  4. K. Taton, D. Johnson, P. Guire, E. Lange, and M. Tondra, "Lateral flow immunoassay using magnetoresistive sensor," J Magn Mater, vol. 321, no. 10, pp. 1679-1682, 2009. https://doi.org/10.1016/j.jmmm.2009.02.113
  5. http://www.ivdtechnology.com/article/highly-sensitive
  6. http://www.ivdtechnology.com/article/developing-highly-sensitive-more-reproducible
  7. Li Z, Wang Y, Wang J, Tang Z, Pounds JG and Lin Y, "Rapid and sensitive detection of protein biomarker using a portable fluorescence biosensor based on quantum dots and a lateral flow test strip," Anal Chem, vol. 82, no. 16, pp. 7008-7014, 2010. https://doi.org/10.1021/ac101405a
  8. Tang D, Sauceda JC, Lin Z, Ott S, Basova E, Goryacheva I, Biselli S, Lin J, Niessner R and Knopp D, "Magnetic nanogold microspheres-based lateral-flow immunodipstick for rapid detection of aflatoxin B2 in food," Biosens Bioelectron, vol. 25, no. 2, pp. 514-518, 2009. https://doi.org/10.1016/j.bios.2009.07.030
  9. Xu Q, Xu H, Gu H, Li J, Wang Y and Wei M, "Development of lateral flow immunoassay system based on superparamagnetic nanobeads as labels for rapid quantitative detection of cardiac troponin I," Mat Sci Eng C-Bio S, vol. 29, no. 3, pp. 702-707, 2009. https://doi.org/10.1016/j.msec.2009.01.009
  10. Wong R and Tse H, Lateral Flow Immunoassay, New York, USA: Humana Press, 2010, pp. 23-25.
  11. Park J, "Diagnosis apparatus and method used in-vitro diagnostics," Rep. of Korea Patent 1011579990000, issued October 27, 2010.
  12. Bayer BE, "Color imaging array," U.S. Patent 3,971,065, issued July 20, 1976.
  13. Seo D, Lee M, Seo B and Park J, "Optimal illumination for maximizing the RGB distance between objects with different spectra," J Biomed Eng Res, vol. 30, no. 3, pp. 263-269, 2009.
  14. Han B and Jung B, "Digital color imaging systems for quantitative evaluation of skin lesions," J Biomed Eng Res, vol. 28, no. 2, pp. 195-198, 2007.
  15. Plebani M and Zaninotto M, "Cardiac markers: present and future," Int J Clin Lab Res, vol. 29, no. 2, pp. 56-63, 1999. https://doi.org/10.1007/s005990050064
  16. Montague C and Kircher T, "Myoglobin in the early evaluation of acute chest pain," Am J Clin Pathol, vol. 104, no. 4, pp. 472-476, 1995. https://doi.org/10.1093/ajcp/104.4.472
  17. http://www.roche.com/products/product-list.htm?type=diagnostics&id=3
  18. Stone MJ, Waterman MR, Harimoto D, Murray G, Willson N, Platt MR, Blomqvist G and Willerson JT, "Serum myoglobin level as diagnostic test in patients with acute myocardial infarction," Br Heart J, vol. 39, no. 4, pp. 375-380, 1977. https://doi.org/10.1136/hrt.39.4.375
  19. Bessman SP and Carpenter CL, "The creatine-creatine phosphate energy shuttle," Ann. Rev Biochem, vol. 54, pp. 831-862, 1985. https://doi.org/10.1146/annurev.bi.54.070185.004151