Abstract

In 1990s, with the increase of domestic building renovation but also increase the amount of anchor. The 45-degree cone failure theory has been used in concrete anchor bolts design, but the CCD (concrete capacity design) method was adopted as a new design method since 2000. However, the method has some problems because it is based on the experimental results of pre-installed concrete anchor bolts. In this study, the objective is to investigate the effects of anchor edge distance, anchor interval and concrete strength on pullout characteristics of post-installed concrete set anchor embedded in plain concrete.

1990년대 들어서, 국내 건물의 리모델링, 보수 및 유지관리의 증가에 따라 앵커의 사용량도 서서히 증가하고 있다. 콘크리트 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2000년 이후부터 CCD(concrete capacity design) 방법이 새로운 설계법으로 도입되었다. 그러나 본 방법은 주로 선설치 콘크리트 앵커볼트에 대한 실험 결과에 근거한 관계로 모든 앵커볼트에 적용하기에는 많은 한계를 갖고 있다. 본 연구에서는 연단거리, 앵커간격 및 콘크리트 강도를 변수로 한 후설치 콘크리트 세트앵커의 인발파괴실험을 통하여 무근콘크리트에 매입된 후설치 세트앵커의 인발특성에 미치는 영향을 규명하는 것을 그 목적으로 한다.

Keywords

References

  1. F. Werner, E. Rolf, E. B. John, "Concrete Capacity Design(CCD) Approach for Fastening to Concrete," ACI Structural Journal. vol. 92, No. 1, pp.73-94, January, 1995.
  2. Korea Concrete Institute, Design Method for Concrete Anchors and Examples, Korea, 2010.
  3. S. Y. Kim, and K. S. Kim, "Shear Strength of Anchors installed in Uncracked and Unreinforced Concrete", Conference of Architectural Institute of Korea, vol. 19, No. 9, pp.69-78, September, 2003.
  4. Y. M. Park, M. H. Jeon, M. K. Choi, C. H. Kim, "A Study on the Concrete Breakout Capacity Evaluation of Medium-to-Large size CIP Anchor Bolts under Tension Loading", Journal of Korean Society of Steel Construction, vol. 23, No. 4, pp.493-501, August, 2011.
  5. H. S. Oh, S. R. Park, "Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts", Journal of the Korea Concrete Institute, vol. 23, No. 4, pp.529-539, August, 2011. DOI: http://dx.doi.org/10.4334/JKCI.2011.23.4.529
  6. S. W. Yoo, S. H. Jung, K. S. Kwak, J. H. Lee, "Experimental Study on Pullout Characteristics of Adhesive Anchor", Journal of the Korean Society of Civil Engineering, vol. 26, No. 3, pp. 555-563, May, 2006.
  7. K. M. Lee, C. Y. Lee, S. H. Jung, S. W. Choi, "Tensile and Shear Test Method for Post-installed Mechanical Anchors Embedded in Concrete", Journal of the Korea Concrete Institute, vol. 21, No. 1, pp.97-98, 2009.
  8. J. B. Jang, and Y. P. Suh, "An Evaluation of Tensile Design Criteria of Cast-In-Place Anchor by Numerical Analysis"Journal of Computational Structural Engineering Institute of Korea, vol. 18, No. 3, pp.303-309, September, 2005.
  9. D. U. Choi, K. H. Kim, "State-of-the-Art on Anchoring to Concrete, Mechanical Anchorage and Splices of Reinforcement", Magazine of the Korea Concrete Institute, vol. 17, No. 5, pp. 16-20, September, 2005.
  10. J. S. Kim, M. H. Kwon, H. S. Seo, J. H. Park, "Performance Evaluation and Analysis Model for the Post-Installed Anchor", Journal of KOSHAM, vol. 13, No. 2, pp.89-95, April, 2013. DOI: http://dx.doi.org/10.9798/KOSHAM.2013.13.2.089