Abstract
A Large-diameter drilled shaft of deep water depth composite foundation supporting a high rise pylon of the test designed super long span bridge was designed by allowable stress design method and failure probability through reliability analysis to bearing capacity was estimated. The allowable stress design results for the bearing capacity of a drilled shaft were analyzed by reliability analysis and the probability of failure shows 0.12 % in case of CFEM, 0.0002 % in case of Korea Highway Corporation criterion, and 0.003 % in case of structure foundation design criterion. In the allowable stress design, the bearing capacity of a large-diameter drilled shaft was obtained by applying to safety factor 3 and reliability analysis for the results was done. If the failure probability suggested by AASHTO(2007) specification is set to 0.02 %, the socketed length of a drilled shaft shows an increase of 25 % in CFEM, decrease of 60 % in KHCC, and decrease of 89 % in SFDC.
시험 설계된 초장대 사장교의 고주탑을 지지하는 대수심 대형 복합기초의 지중 대구경 현장타설말뚝을 허용응력 설계법으로 설계하고, 지지력에 대한 신뢰성 해석을 통해 파괴확률을 평가하였다. 말뚝의 지지력에 대한 허용응력 설계 결과를 신뢰성 해석으로 분석하였으며 파괴확률은 CFEM의 경우 0.12 %, 한국도로공사기준 방법의 경우 0.0002 %, 구조물기초설계기준의 경우 0.003 %였다. 허용응력 설계에서는 안전율 3을 적용하여 대구경 현장타설말뚝의 허용지지력을 구하였으며, 그 결과에 대한 신뢰성 해석을 실시하였다. AASHTO(2007)에서 제시하고 있는 파괴확률($P_f$) 0.02 %일 때 CFEM 방법에서는 근입 깊이가 25 % 만큼 증가하였으며 한국도로공사기준(KHCC)에서는 근입깊이를 60 %, 구조물기초설계기준(SFDC)에서는 근입 깊이를 89 % 만큼 감소시킬 수 있었다.