Abstract

For an analysis of the horizontal-type geothermal heat exchanger system, an understanding of the ground temperature distributions is required in order to predict system performance. Because it is difficult to decide on the underground temperature due to the adjustment of its temperature cycle, numerous calculations are required in order to decide on the temperature cycle. In this paper, Buggs formula is utilized to decide a phase shift for outdoor temperature and ground surface temperature, which are obtained from Korea Meteorological Administration. Overall, the underground temperature distribution in the Changwon region is predicted as $10.5^{\circ}C{\sim}20.3^{\circ}C$ at a depth of 3 m.

Keywords

References

  1. Lee, K. H., 2012, The effect of an earth tube system on cooling and heating loads in residential buildings under korean climatic conditions, AIJ, Vol. 26, No. 8, pp. 281-288.
  2. Lee, Y. G. and Yoon, J. H., 2001, Optimal system design method for a building application of cool tube system, AIJ, Vol. 17, No. 6, pp. 177-186.
  3. Sohn, B. H., 2011, Evaluation of ground temperature and soil thermal diffusivity using the soil temperature data of KMA, Korean Society of Geothermal Energy Engineers, Vol .7, No. 1, pp. 1-9.
  4. Mihalakakou, G., Santamouris, M., Lewis, J. O. D., and Asimakopoulos, N., 1997, On the application of the energy balance equation to predict ground temperature profiles, Solar Energy, Vol. 60, No. 3, pp. 181-190. https://doi.org/10.1016/S0038-092X(97)00012-1
  5. Popiel, C. O., Wojtkowiak, J., and Biernacka, B., 2001, Measurements of temperature distribution in ground, Experimental thermal and Fluid Science, Vol. 25, pp. 301-309. https://doi.org/10.1016/S0894-1777(01)00078-4
  6. Yang, Y. S. and Park, J. I., 2013, Analysis of design in geothermal system, SAREK Proceeding, pp. 865-868.