DOI QR코드

DOI QR Code

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service

상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례

  • Lee, Jun-Sik (Department of Prosthodontics, College of Dentistry, Dankook University) ;
  • Han, Se-Jin (Department of Oral and Maxillofacial Surgery, College of Dentistry, Dankook University) ;
  • Choi, Yu-Sung (Department of Prosthodontics, College of Dentistry, Dankook University)
  • 이준식 (단국대학교 치과대학 치과보철학교실) ;
  • 한세진 (단국대학교 치과대학 구강악안면외과학교실) ;
  • 최유성 (단국대학교 치과대학 치과보철학교실)
  • Received : 2014.01.02
  • Accepted : 2014.03.11
  • Published : 2014.03.31

Abstract

Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

골흡수가 심한 환자에서 임플란트를 이용한 전악 수복의 경우 치은과 치아의 외형을 심미적이면서도 기능적으로 회복하기 위해서는 보철물 제작에 있어 신중을 기해야 한다. 이러한 전악 수복 증례에서 CAD/CAM 시스템이 높은 정확성을 가지는 보철물 제작을 가능하게 함으로써 사용이 증가하고 있다. 최근에 임상에서 티타늄이나 지르코니아의 단점을 보완하면서 높은 생체적합성을 가지고 CAD/CAM 시스템으로 제작할 수 있는 팔라듐-은(Pd-Ag) 합금이 개발되어 사용되고 있다. 본 증례에서는 상악 전부 무치악 환자에서 임플란트를 식립하고 도재의 chipping이나 파절의 위험을 감소시키기 위해 Pd-Ag 합금을 이용해 제작된 임플란트 고정성 보철물로 수복한 환자에 대해 보고하고자 한다.

Keywords

References

  1. Purcell BA, McGlumphy EA, Holloway JA, Beck FM. Prosthetic complications in mandibular metalresin implant-fixed complete dental prostheses: a 5-to 9-year analysis. Int J Oral Maxillofac Implants 2008;23:847-57.
  2. Duncan JP, Nazarova E, Vogiatzi T, Taylor TD. Prosthodontic complications in a prospective clinical trial of single-stage implants at 36 months. Int J Oral Maxillofac Implants 2003;18:561-5.
  3. Bozini T, Petridis H, Garefis K, Garefis P. A meta-analysis of prosthodontics complication rates of implant-supported fixed dental prostheses in edentulous patients after an observation period of at least 5 years. Int J Oral Maxillofac Implants 2011;26:304-18.
  4. Ortorp A, Jemt T. Early laser-welded titanium frameworks supported by implants in the edentulous mandible: a 15-year comparative follow-up study. Clin Implant Dent Relat Res 2009;11:311-22. https://doi.org/10.1111/j.1708-8208.2008.00119.x
  5. Larsson C, Vult von Steyern P, Nilner K. A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results. Int J Prosthodont 2010;23:364-9.
  6. Ortorp A, Jemt T. Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw: 1-year prospective study. Clin Implant Dent Relat Res 2000;2:2-9. https://doi.org/10.1111/j.1708-8208.2000.tb00101.x
  7. Linkevicius T, Vladimirovas E, Grybauskas S, Puisys A, Rutkunas V. Veneer fracture in implant-supported metal-ceramic restorations. Part I: Overall success rate and impact of occlusal guidance. Stomatologija 2008;10:133-9.
  8. Katsoulis J, Mericske-Stern R, Rotkina L, Zbaren C, Enkling N, Blatz MB. Precision of fit of implantsupported screw-retained 10-unit computeraided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study. Clin Oral Implants Res 2014;25:165-74. https://doi.org/10.1111/clr.12039
  9. Gilbert JL, Covey DA, Lautenschlager EP. Bond characteristics of porcelain fused to milled titanium. Dent Mater 1994;10:134-40. https://doi.org/10.1016/0109-5641(94)90054-X
  10. Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005;113:174-9. https://doi.org/10.1111/j.1600-0722.2004.00197.x
  11. Bachhav VC, Aras MA. Zirconia-based fixed partial dentures: a clinical review. Quintessence Int 2011;42:173-82.
  12. Huget EF, Civjan S. Status report on palladium-silver-based crown and bridge alloys. J Am Dent Assoc 1974;89:383-5. https://doi.org/10.14219/jada.archive.1974.0426
  13. Goodacre CJ. Palladium-silver alloys: a review of the literature. J Prosthet Dent 1989;62:34-7. https://doi.org/10.1016/0022-3913(89)90043-7
  14. Kansu G, Aydin AK. Evaluation of the biocompatibility of various dental alloys: Part I-Toxic potentials. Eur J Prosthodont Restor Dent 1996;4:129-36.
  15. Henry PJ. An alternate method for the production of accurate casts and occlusal records in the osseointegrated implant rehabilitation. J Prosthet Dent 1987;58:694-7. https://doi.org/10.1016/0022-3913(87)90421-5
  16. Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-5.
  17. Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6:346-63.
  18. Roberts DH. The failure of retainers in bridge prostheses. An analysis of 2,000 retainers. Br Dent J 1970;128:117-24. https://doi.org/10.1038/sj.bdj.4802433
  19. Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater 2008;24:299-307. https://doi.org/10.1016/j.dental.2007.05.007
  20. Barghi N, McKeehan-Whitmer M, Aranda R. Comparison of fracture strength of porcelain-veneeredto-high noble and base metal alloys. J Prosthet Dent 1987;57:23-6. https://doi.org/10.1016/0022-3913(87)90110-7
  21. Warpeha WS Jr, Goodkind RJ. Design and technique variables affecting fracture resistance of metalceramic restorations. J Prosthet Dent 1976;35:291-8. https://doi.org/10.1016/0022-3913(76)90253-5
  22. Anusavice KJ, Dehoff PH, Gray A, Lee RB. Delayed crack development in porcelain due to incompatibility stress. J Dent Res 1988;67:1086-91. https://doi.org/10.1177/00220345880670080501
  23. Rosenstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 4th ed. New York; Elsevier Inc.; 2006. p. 743-50.