DOI QR코드

DOI QR Code

Clinical Experience with Buttonhole Needling in a Single Hemodialysis Center

단일 혈액투석 기관에서 Buttonhole 천자의 경험

  • Choi, Soo Jeong (Division of Nephrology, Department of Internal Medicine, Soonchunhyang University College of Medicine) ;
  • Cho, Eun Hee (Artificial Kidney Unit, Soonchunhyang University Bucheon Hospital) ;
  • Lee, Sul Hyung (Artificial Kidney Unit, Soonchunhyang University Bucheon Hospital) ;
  • Oh, Hye Ran (Artificial Kidney Unit, Soonchunhyang University Bucheon Hospital) ;
  • Kim, Jong Hye (Artificial Kidney Unit, Soonchunhyang University Bucheon Hospital) ;
  • Park, Moo Yong (Division of Nephrology, Department of Internal Medicine, Soonchunhyang University College of Medicine) ;
  • Kim, Jin Kuk (Division of Nephrology, Department of Internal Medicine, Soonchunhyang University College of Medicine) ;
  • Hwang, Seung Duk (Division of Nephrology, Department of Internal Medicine, Soonchunhyang University College of Medicine)
  • 최수정 (순천향대학교 의과대학 내과학교실) ;
  • 조은희 (순천향대학교 부천병원 인공신장실) ;
  • 이설형 (순천향대학교 부천병원 인공신장실) ;
  • 오혜란 (순천향대학교 부천병원 인공신장실) ;
  • 김종혜 (순천향대학교 부천병원 인공신장실) ;
  • 박무용 (순천향대학교 의과대학 내과학교실) ;
  • 김진국 (순천향대학교 의과대학 내과학교실) ;
  • 황승덕 (순천향대학교 의과대학 내과학교실)
  • Received : 2013.12.31
  • Accepted : 2014.04.30
  • Published : 2014.11.01

Abstract

Background/Aims: The buttonhole technique, in which needle insertion during cannulation is always into the same site, confers advantages including ease of cannulation, ease of achieving hemostasis, and reduced pain compared with rope-ladder needling. We introduced the buttonhole technique in hemodialysis patients experiencing pain during needling. None of the disadvantages associated with the buttonhole technique, such as infection or access events, were observed, due to the short duration of the study. Methods: Patients undergoing buttonhole needling were observed prospectively. Data were collected on the following parameters: infectious complications, hospitalizations and access events. We compared buttonhole and rope-ladder needling using baseline data. Results: A total of 48 patients (34 males; mean age = $49.4{\pm}13.8$ years) were enrolled. Seven patients were excluded: in three patients, the buttonhole technique failed to form a tract, three others underwent kidney transplantation, and one was lost to follow-up. The remaining 41 patients were followed for $15.7{\pm}4.7$ months. Thirteen patients suffered infections, as follows: local infections (n = 5), pneumonia (n = 3), bacteremia (n = 2), cellulitis (n = 1), osteomyelitis (n = 1), and liver abscess (n = 1). There were no significant differences between the rope-ladder and buttonhole needling techniques in rates of infection, hospitalization or vascular access events. Conclusions: The infection rate and access event frequency associated with buttonhole needling did not differ in relation to that of rope-ladder needling.

목적: Buttonhole 천자는 혈액투석 시에 같은 부위를 천자해 천자가 쉽고, 통증이 적으며, 지혈이 빠른 장점들이 있어 국내에선 최근에 저자들에 의해 소개되었다. 방법: 2011년 7월부터 12월까지 buttonhole을 만들고 2013년 2월까지의 buttonhole 천자를 받았던 환자에게서 감염, 입원 및 동정맥루 사건을 조사하여, 동일 환자의 1년 전 ropeladder법으로 투석한 기간의 자료와 비교 분석하였다. 결과: 총 48명(남자 34명, 나이 $49.4{\pm}13.8$세)이 buttonhole 술기를 시작하였고, 3명은 buttonhole을 만들지 못하였고, 3명은 이식, 1명은 전원으로 buttonhole 술기를 중단하였다. Buttonhole 천자를 지속한 41명의 $15.1{\pm}4.7$개월 추적기간에 13명(29.2%)에서 감염이 발생하였고, 동정맥루 국소감염 5명, 폐렴 3명, 균혈증 2명, 봉와직염 1명, 간농양 1명, 골수염 1명 순이었다. 이들의 rope-ladder 천자 기간과 buttonhole 기간의 감염, 입원, 동정맥루 사건은 유의한 차이가 없었다. 결론: Buttonhole 천자는 rope-ladder천자에 비해 감염, 입원 및 동정맥루 사건의 유의한 차이가 없다.

Keywords

References

  1. Hartig V, Smyth W. "Everyone should buttonhole": a novel technique for a regional Australian renal service. J Ren Care 2009;35:114-119. https://doi.org/10.1111/j.1755-6686.2009.00103.x
  2. Choi SJ, Lee SH, Cho EH, et al. Clinical Utility of the Buttonhole Technique Using Biohole(TM) in Hemodialysis Patients. Korean J Med 2012;82:307-312. https://doi.org/10.3904/kjm.2012.82.3.307
  3. Kim MK, Kim HS. Clinical effects of buttonhole cannulation method on hemodialysis patients. Hemodial Int 2013;17:294-299. https://doi.org/10.1111/j.1542-4758.2012.00753.x
  4. Verhallen AM, Kooistra MP, van Jaarsveld BC. Cannulating in haemodialysis: rope-ladder or buttonhole technique? Nephrol Dial Transplant 2007;22:2601-2604. https://doi.org/10.1093/ndt/gfm043
  5. Marticorena RM, Hunter J, Macleod S, et al. The salvage of aneurysmal fistulae utilizing a modified buttonhole cannulation technique and multiple cannulators. Hemodial Int 2006;10:193-200. https://doi.org/10.1111/j.1542-4758.2006.00094.x
  6. Chow J, Rayment G, San Miguel S, Gilbert M. A randomised controlled trial of buttonhole cannulation for the prevention of fistula access complications. J Ren Care 2011;37:85-93. https://doi.org/10.1111/j.1755-6686.2011.00211.x
  7. Twardowski Z. Different sites versus constant sites of needle insertion into arteriovenous fistulas for treatment by repeated dialysis. Dial Trasnplant 1979;8:978-980.
  8. Hayashi R, Huang E, Nissenson AR. Vascular access for hemodialysis. Nat Clin Pract Nephrol 2006;2:504-513.
  9. Tordoir J, Canaud B, Haage P, et al. EBPG on Vascular Access. Nephrol Dial Transplant 2007;22 Suppl 2:ii88-117.
  10. Ohira S, Naito H, Amano I, et al. 2005 Japanese Society for Dialysis Therapy guidelines for vascular access construction and repair for chronic hemodialysis. Ther Apher Dial 2006;10:449-462. https://doi.org/10.1111/j.1744-9987.2006.00410.x
  11. Murcutt G. Buttonhole cannulation: should this become the default technique for dialysis patients with native fistulas? Summary of the EDTNA/ERCA Journal Club discussion Autumn 2007. J Ren Care 2008;34:101-108. https://doi.org/10.1111/j.1755-6686.2008.00019.x
  12. Vaux E, King J, Lloyd S, et al. Effect of buttonhole cannulation with a polycarbonate PEG on in-center hemodialysis fistula outcomes: a randomized controlled trial. Am J Kidney Dis 2013;62:81-88. https://doi.org/10.1053/j.ajkd.2013.01.011
  13. Macrae JM, Ahmed SB, Hemmelgarn BR; Alberta Kidney Disease Network. Arteriovenous fistula survival and needling technique: long-term results from a randomized buttonhole trial. Am J Kidney Dis 2014;63:636-642. https://doi.org/10.1053/j.ajkd.2013.09.015
  14. Doss S, Schiller B, Moran J. Buttonhole cannulation--an unexpected outcome. Nephrol Nurs J 2008;35:417-419.
  15. van Loon MM, Goovaerts T, Kessels AG, van der Sande FM, Tordoir JH. Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. Nephrol Dial Transplant 2010;25:225-230. https://doi.org/10.1093/ndt/gfp420
  16. Birchenough E, Moore C, Stevens K, Stewart S. Buttonhole cannulation in adult patients on hemodialysis: an increased risk of infection? Nephrol Nurs J 2010;37:491-498.
  17. Labriola L, Crott R, Desmet C, Andre G, Jadoul M. Infectious complications following conversion to buttonhole cannulation of native arteriovenous fistulas: a quality improvement report. Am J Kidney Dis 2011;57:442-448. https://doi.org/10.1053/j.ajkd.2010.10.045
  18. Van Eps CL, Jones M, Ng T, et al. The impact of extended- hours home hemodialysis and buttonhole cannulation technique on hospitalization rates for septic events related to dialysis access. Hemodial Int 2010;14:451-463. https://doi.org/10.1111/j.1542-4758.2010.00463.x

Cited by

  1. 혈액투석실에서 근무하는 간호사의 특성이 근거기반 혈액투석간호지식과 수행정도에 미치는 영향 vol.22, pp.2, 2016, https://doi.org/10.22650/jkcnr.2016.22.2.225