DOI QR코드

DOI QR Code

Comparison Analysis of Induction Motor using the Equivalent Circuit

등가회로도를 이용한 유도전동기의 특성 비교 분석

  • 김종겸 (강릉원주대학교 전기공학과)
  • Received : 2013.11.23
  • Accepted : 2014.02.18
  • Published : 2014.03.01

Abstract

Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor is generally applied to the constant speed operation. Induction motor generates a high current at startup. So analysis for both steady state operation and start-up transient is required. In most cases, an equivalent circuit is used for the characteristics analysis of the induction motor. In this study, the two programs are applied to analyze for the rated speed as well as entire speed range. We confirmed that calculation results of the two programs are similar to each other.

Keywords

References

  1. Theodore Wildi, "Electrical Machines, Drives and Power Systems", Prentice Hall, 2002
  2. Jong-Gyeum Kim, Eun-Woong Lee, "The Characteristic Analysis of Adjustable Speed Driving Systems using EMTP", KIEE, Vol.47, No.8, pp.25-31, 1998. 08
  3. Jong-Gyeum Kim, Youn-Jeen Park, Jong-Ho Jeong, Eun-Woong Lee, "Analysis on the Operation Characteristics of Induction motor operated by Unbalanced Voltage", KIEE, Vol.53, No.3, pp.372-379, 2004.06
  4. Jong-Gyeum Kim, "Output characterization analysis of Induction generator using test data", KIEE, Vol.62, No.07, pp.1027-1032, 2013.07 https://doi.org/10.5370/KIEE.2013.62.7.1027
  5. IEEE Standard Test Procedure for Polyphase Induction Motors and Generator,. IEEE Std,112-2004, 2004.
  6. Mathcad User's Guide Manual, 2011
  7. H.W. Dommel, "Electromagnetic Transients Program. Reference Manual (EMTP Theory Book)", BPA 1986.