This paper examines the behaviour of two types of practical open beam-to-tubular column connection details subjected to combined moment, axial and/or shear loads. Detailed continuum finite element models are developed and validated against available experimental results, and extended to deal with flexural, axial and shear load interactions. A numerical investigation is then carried out on the behaviour of selected connections with different stiffness and strength characteristics under various load combination scenarios. The influence of applied levels of axial tensile or compressive loads on the bending stiffness and capacity is examined and discussed. Additionally, the interaction effects between shear forces and co-existing bending and axial loads are examined and shown to be comparatively insignificant in terms of stiffness and capacity in most cases. It is also shown that the range of connections considered in this paper can provide rotational ductility levels in excess of those required under typical design scenarios. Based on these findings, a simplified component-based representation is proposed and described, and its ability to represent the connection response under combined loading is verified using results from detailed numerical simulations.

키워드

참고문헌

  1. ABAQUS (2003), "ABAQUS Theory Manual,Version 6.7", Hibbit, Karlsson and Sorensen Inc.
  2. ANSYS (2003), "ANSYS Multiphisics 10.0", Canonsbury, Pennsylvania Inc.
  3. Barnett, T., Tizani, W. and Nethercot, D. (2001), "The prictice of blind bolting connections to structural hollow sections : A review", Steel Compos. Struct., Int. J., 1(1), 1-16. https://doi.org/10.12989/scs.2001.1.1.001
  4. De Lima, L.R., L. Simoes da Silva, P.C. Vellasco and S.A. De Andrade (2004), "Experimental evaluation of extended endplate beam-to-column joints subjected to bending and axial force", Eng. Struct., 26(10), 1333-1347. https://doi.org/10.1016/j.engstruct.2004.04.003
  5. Ding, J. and Wang, Y.C. (2007), "Experimental study of structural fire behaviour of steel beam to concrete filled tubular column assemblies with different types of joints", Eng. Struct., 29(12), 3485-3502. https://doi.org/10.1016/j.engstruct.2007.08.018
  6. Comite Europeen de Normalisation (2005), CEN.EN1993-1-8, Eurocode 3: Design of steel structures, Part 1-8: Design of Joints.
  7. Elghazouli, A.Y. and Izzuddin, B.A. (2000), "Response of idealised composite beam-slab systems under fire conditions", J. Construct. Steel Res., 56(3), 199-224. https://doi.org/10.1016/S0143-974X(00)00006-7
  8. Elghazouli, A.Y. and Izzuddin, B.A. (2001), "Analytical assessment of the structural performance of composite floors subject to compartment fires", Fire Safe. J., 36(8), 769-793. https://doi.org/10.1016/S0379-7112(01)00039-X
  9. Elghazouli, A.Y., Malaga-Chuquitaype, C., Castro, J.M. and Orton, A.H. (2009), "Experimental monotonic and cyclic behaviour of blind-bolted angle connections", Eng. Struct., 31(11), 2540-2553. https://doi.org/10.1016/j.engstruct.2009.05.021
  10. Faella, C., Piluso, V. and Rizzano, G. (2000), Structural Steel Semi-Rigid Connections: Theory, Design and Software, CRC Press, Florida, USA.
  11. France, J.E., Buick Davison, J. and Kirby, P.A. (1999), "Strength and rotational stiffness of simple connections to tubular columns using flowdrill connectors", J. Construct. Steel Res., 50(1), 15-34. https://doi.org/10.1016/S0143-974X(98)00236-3
  12. Ghobarah, A., Mourad, S. and Korol, R.M. (1996), "Moment-rotation relationship of blind bolted connections for HSS columns", J. Construct. Steel Res., 40(1), 63-91. https://doi.org/10.1016/S0143-974X(96)00044-2
  13. Gomes, F.C.T. (1996), "Moment capacity of beam-to-column minoraxis joints", Proceedings of IABSE International Colloquium on Semi-Rigid Structural Connections, Istanbul, Turkey, IABSE: 319-326.
  14. Huck International Inc. (1990), Industrial Fastening System, Arizona, USA.
  15. Lee, J., Goldsworthy, H.M. and Gad, E.F. (2011), "Blind bolted moment connection to unfilled hollow section columns using extended T-stub with back face support", Eng. Struct., 33(5), 1710-1722. https://doi.org/10.1016/j.engstruct.2011.02.008
  16. Liu, T.C.H., Fahad, M.K. and Davies, J.M. (2002), "Experimental investigation of behaviour of axially restrained steel beams in fire", J. Construct. Steel Res., 58(9), 1211-1230. https://doi.org/10.1016/S0143-974X(01)00062-1
  17. Liu, Y. (2012), "Behaviour of steel connections under extreme loading conditions", Ph.D. Thesis, Department of Civil and Environmental Engineering, Imperial College London, UK.
  18. Liu, Y., Malaga-Chuquitaype, C. and Elghazouli, A.Y. (2012a), "Response and component characterisation of semi-rigid connections to tubular columns under axial loads", Eng. Struct., 41, 510-532. https://doi.org/10.1016/j.engstruct.2012.03.061
  19. Liu, Y., Malaga-Chuquitaype, C. and Elghazouli, A.Y. (2012b), "Behaviour of beam-to-tubular column angle connections under shear loads", Eng. Struct., 42, 434-456. https://doi.org/10.1016/j.engstruct.2012.04.027
  20. Malaga-Chuquitaype, C. (2011), "Seismic behaviour and design of steel frames incorporating tubular members", Ph.D. Thesis, Department of Civil and Environmental Engineering, Imperial College London, UK.
  21. Malaga-Chuquitaype, C. and Elghazouli, A.Y. (2010a), "Behaviour of combined channel/angle connections to tubular columns under monotonic and cyclic loading", Eng. Struct., 32(6), 1600-1616. https://doi.org/10.1016/j.engstruct.2010.02.008
  22. Malaga-Chuquitaype, C. and Elghazouli, A.Y. (2010b), "Component-based mechanical models for blind-bolted angle connections", Eng. Struct., 32(10), 3048-3067. https://doi.org/10.1016/j.engstruct.2010.05.024
  23. Park, A.Y. and Wang, Y.C. (2012), "Development of component stiffness equations for bolted connections to RHS columns", J. Construct. Steel Res., 70, 137-152. https://doi.org/10.1016/j.jcsr.2011.08.004
  24. Pucinotti, R. (2001), "Top-and-seat and web angle connections: Prediction via mechanical model", J. Construct. Steel Res., 57(6), 661-694.
  25. Simoes da Silva, L., De Lima, L.R.O., Da S. Vellasco, P.C.G. and De Andrade, S.A.L. (2004), "Behaviour of flush endplate beam-to-bolumn joints under bending and axial force", Steel Compos. Struct., Int. J., 4(2), 77-94. https://doi.org/10.12989/scs.2004.4.2.077
  26. Tizani, W., Wang, Z.Y. and Hajirasouliha, I. (2013), "Hysteretic performance of a new blind bolted connection to concrete filled columns under cyclic loading: An experimental investigation", Eng. Struct., 46, 535-546. https://doi.org/10.1016/j.engstruct.2012.08.020
  27. Urbonas, K. and Daniunas, A. (2006), "Behaviour of semi-rigid steel beam-to-beam joints under bending and axial forces", J. Construct. Steel Res., 62(12), 1244-1249. https://doi.org/10.1016/j.jcsr.2006.04.024
  28. Vlassis, A.G., Izzuddin, B.A., Elghazouli, A.Y. and Nethercot, D.A. (2008), "Progressive collapse of multi-storey buildings due to sudden column loss-Part II: Application", Eng. Struct., 30(5), 1424-1438. https://doi.org/10.1016/j.engstruct.2007.08.011
  29. Vlassis, A.G., Izzuddin, B.A., Elghazouli, A.Y. and Nethercot, D.A. (2009), "Progressive collapse of multi-storey buildings due to failed floor impact", Eng. Struct., 31(7), 1522-1534. https://doi.org/10.1016/j.engstruct.2009.02.009
  30. Wang, Z.Y., Tizani, W. and Wang, Q.Y. (2010), "Strength and initial stiffness of a blind-bolt connection based on the T-stub model", Eng. Struct., 32(9), 2505-2517. https://doi.org/10.1016/j.engstruct.2010.04.005
  31. Yang, J.G., Murray, T.M. and Plaut, R.H. (2000), "Three-dimensional finite element analysis of double angle connections under tension and shear", J. Construct. Steel Res., 54(2), 227-244. https://doi.org/10.1016/S0143-974X(99)00048-6
  32. Yeomans, N.F. (1998), Rectangular Hollow Section Column using Lindapter Hollobolt, (Choo and van der Vegte Eds.), Tubular Structures VIII, Rotterdam, Balkema, pp. 559-566.

피인용 문헌

  1. Estimation of peak displacements in steel structures through dimensional analysis and the efficiency of alternative ground-motion time and length scales vol.101, 2015, https://doi.org/10.1016/j.engstruct.2015.07.019
  2. A Novel Approach for Bolted T-Stub Connections vol.18, pp.3, 2018, https://doi.org/10.1007/s13296-018-0034-x
  3. Studies on performance and failure mode of T-shaped diaphragm-through connection under monotonic and cyclic loading vol.13, pp.1, 2018, https://doi.org/10.2140/jomms.2018.13.1
  4. Anchored blind bolted composite connection to a concrete filled steel tubular column vol.23, pp.1, 2014, https://doi.org/10.12989/scs.2017.23.1.115
  5. Numerical study of internally reinforced circular CFT column-to-foundation connection according to design variables vol.23, pp.4, 2014, https://doi.org/10.12989/scs.2017.23.4.445
  6. Review on the Research Progress of Blind Bolts for Assembly Steel Structures vol.8, pp.2, 2014, https://doi.org/10.12677/hjce.2019.82034
  7. Computational and experimental analysis of beam to column joints reinforced with CFRP plates vol.30, pp.3, 2014, https://doi.org/10.12989/scs.2019.30.3.271
  8. An Overview of Progressive Collapse Behavior of Steel Beam-to-Column Connections vol.10, pp.17, 2014, https://doi.org/10.3390/app10176003