DOI QR코드

DOI QR Code

The Quantification and Validation of Loxoprofen using Near-infrared(NIR) Spectrum Method

근적외부스펙트럼 측정법을 이용한 록소프로펜의 정량화 및 밸리데이션

  • Choi, Sung-Up (Department of Food Science and Biotechnology, Dongnam Health College)
  • 최성업 (동남보건대학교 식품생명과학과)
  • Received : 2013.11.05
  • Accepted : 2014.01.09
  • Published : 2014.01.31

Abstract

In this study, we used NIR spectrum method instead of conventional HPLC method to shorten the analysis and manufacturing time of the loxoprofen products. Loxoprofen mixtures with other pharmaceutical additives were prepared and evaluated by the NIR spectrometer and the HPLC system. Validation of both methods was performed for specificity, accuracy and precision. NIR spectrometer method was validated and revealed proper results for the in-process quality control in the pharmaceutical field. In conclusion, NIR spectrometry can be replaced by HPLC method.

본 논문에서는 록소프로펜 제제의 분석 시간을 단축하고 제품 출하 속도를 향상시키기 위하여 근적외부(NIR) 스펙트럼 측정법을 이용하여 기존에 사용하던 HPLC 방법과 상호 비교해 보고자 하였다. 제제학적으로 사용되는 다른 첨가제들과 함께 록소프로펜 혼합시료를 제조하고, NIR 분광광도계와 HPLC로 록소프로펜을 정량하고 평가하였다. 두 시험법의 밸리데이션 항목으로 특이성, 정확성 및 정밀성을 실시하였다. NIR 측정법이 검증되었고, 제약산업 분야의 제조공정 중 품질관리를 위한 적합한 결과를 얻었다. 결론적으로 록소프로펜을 분석하는데 있어서 NIR 측정법을 사용하면 기존의 HPLC 정량법을 NIR의 결과로 대치할 수 있을 것이다.

Keywords

References

  1. H. I. Shin, B. H. Kim, H. S. Chang, C. H. Park, C. I. Kim, "Long-term effect of loxoprofen sodium on nocturia in patients with benign prostatic hyperplasia", Korean J Urol, Vol. 52(4), pp. 265-268, 2011. DOI: http://dx.doi.org/10.4111/kju.2011.52.4.265
  2. M. Hamaguchi, T. Seno, A. Yamamoto, M. Kohno, M. Kadoya, H. Ishino, E. Ashihara, S. Kimura, Y. Tsubakimoto, H. Takata, T. Yoshikawa, T. Maekawa, Y. Kawahito, "Loxoprofen sodium, a non-selective NSAID, reduces atherosclerosis in mice by reducing inflammation", J Clin Biochem Nutr, Vol. 47(2), pp. 138-47, 2010. DOI: http://dx.doi.org/10.3164/jcbn.10-33
  3. M. Sekiguchi, M. Shirasaka, S. Konno, S. Kikuchi, "Analgesic effect of percutaneously absorbed non-steroidal anti-inflammatory drugs: an experimental study in a rat acute inflammation model", BMC Musculoskelet Disord, Vol. 9:15, 2008 (http://www.biomedcentral.com/1471-2474/9/15). https://doi.org/10.1186/1471-2474-9-15
  4. P. Loya, A. A. Kshatriya, M. N. Saraf, "Bioequivalence study of two brands of loxoprofen tablets in healthy volunteers", Int J PharmTech Research, Vol. 3(4), pp. 2038-2046, 2011.
  5. J. H. OH, M. H. Lee, L. M. Shaw, S. E. Lee, J. H. Park, J. S. Kang, "Pharmacokinetics and bioequivalence study of two brands of loxoprofen tablets in healthy volunteers", Arzneimittelforschung, Vol. 57(8), pp. 542-546, 2007.
  6. N. Yamakawa, S. Suemasu, H. Watanabe, K. Tahara, K. Tanaka, Y. Okamoto, M. Ohtsuka, T. Maruyama, T. Mizushima, "Comparison of pharmacokinetics between loxoprofen and its derivative with lower ulcerogenic activity, fluoro-loxoprofen", Drug Metab Pharmacokinet, Vol. 28(2), pp. 118-124, 2013. DOI: http://dx.doi.org/10.2133/dmpk.DMPK-12-RG-050
  7. M. J. Maltesen, M. van de Weert, H. Grohganz, "Design of experiments-based monitoring of critical quality attributes for the spray-drying process of insulin by NIR spectroscopy", AAPS PharmSciTech, Vol. 13(3), pp. 747-755, 2012. DOI: http://dx.doi.org/10.1208/s12249-012-9796-1
  8. K. Aaljoki, "Automated quality assurance of online NIR analysers", J Autom Methods Manag Chem, Vol. 2005(2), pp. 44-49, 2005. DOI: http://dx.doi.org/10.1155/JAMMC.2005.44
  9. C. Schaefer, C. Lecomte, D. Clicq, A. Merschaert, E. Norrant, F. Fotiadu, "On-line near infrared spectroscopy as a Process Analytical Technology (PAT) tool to control an industrial seeded API crystallization", J Pharm Biomed Anal, Vol. 83, pp. 194-201, 2013. DOI: http://dx.doi.org/10.1016/j.jpba.2013.05.015
  10. A. Burggraeve, A. F. Silva, T. van den Kerkhof, M. Hellings, C. Vervaet, J. P. Remon, Y. van der Heyden, T. De Beer, "Development of a fluid bed granulation process control strategy based on real-time process and product measurements", Talanta, Vol. 100, pp. 293-302, 2012. DOI: http://dx.doi.org/10.1016/j.talanta.2012.07.054
  11. S. H. Lee, J. H. Lee, S. Cho, S. H. Do, Y. A. Woo, "End point determination of blending process for trimebutine tablets using principle component analysis (PCA) and partial least squares (PLS) regression", Arch Pharm Res, Vol. 35(9), pp. 1599-1607, 2012. DOI: http://dx.doi.org/10.1007/s12272-012-0911-3
  12. J. G. Rosas, M. Blanco, J. M. Gonzalez, M. Alcala, "Real-time determination of critical quality attributes using near-infrared spectroscopy: a contribution for Process Analytical Technology (PAT)", Talanta, Vol. 97, pp. 163-170, 2012. DOI: http://dx.doi.org/10.1016/j.talanta.2012.04.012
  13. E. T. Skibsted, H. F. Boelens, J. A. Westerhuis, D. T. Witte, A. K. Smilde, "Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts", J Pharm Biomed Anal, Vol. 41(1), pp. 26-35, 2006. DOI: http://dx.doi.org/10.1016/j.jpba.2005.10.009
  14. Y. A. Woo, "Content uniformity in granules for aceclofenac controlled release (CR) tablets determined using near-infrared spectroscopy and wide area illumination (WAI) Raman spectroscopy", Arch Pharm Res, Vol. 35(2), pp. 351-358, 2012. DOI: http://dx.doi.org/10.1007/s12272-012-0216-6
  15. M. Blanco, A. Peguero, "Influence of physical factors on the accuracy of calibration models for NIR spectroscopy", J Pharm Biomed Anal, Vol. 52(1), pp. 59-65, 2010. DOI: http://dx.doi.org/10.1016/j.jpba.2009.12.009
  16. Y. H. Kim, B. R. Choi, H. Y. Baek, Y. S. Lee, "Quantification of icariin contents in Epimedium koreanum N. by using a Near Infrared Reflectance Spectroscopy", J Kor Medical Crop Sci, Vol. 10(5), pp. 340-343, 2002.
  17. J. U. Chun, K. S. Choi, "Nondestructive and rapid method for measurement of catechin contents in green tea products using NIRS", J Kor Tea Soc, Vol. 13(3), pp. 99-112, 2007.
  18. C. R. Park, A. Y. Kim, M. J. Lee, H. E. Lee, D. Y. Seo, S. Shin, Y. Choi, B. S. Kwon, K. H. Bang, H. K. Kang, C. K. Kim, S. K. Lee, G. J. Choi, "In-line monitoring of fluid-bed blending process for pharmaceutical powders using fiber optics probe and NIR spectroscopy", J Kor Pharm Sci, Vol. 39(1), pp. 29-36, 2009. DOI: http://dx.doi.org/10.4333/KPS.2009.39.1.029
  19. D. H. Kim, Y. A. Woo, H. J. Kim, "Quantitative analysis of indomethacin by the portable near-infrared (NIR) system", Yakhak Hoeji, Vol. 47(5), pp. 261-265, 2003.
  20. C. H. Cho, H. J. Kim, D. Y. Meang, S. H. Seo, J. H. Cho, "Quantitative analysis of taurine using near infrared spectrometry (NIRS)", Yakhak Hoeji, Vol. 42(6), pp. 545-551, 1998.
  21. J. H. Baek, N. Kang, Y. A. Woo, H. J. Kim, "Aqueous glucose solution measurement by three types NIR spectrometer", Yakhak Hoeji, Vol. 47(6), pp. 461-468, 2003.