References
- H. I. Shin, B. H. Kim, H. S. Chang, C. H. Park, C. I. Kim, "Long-term effect of loxoprofen sodium on nocturia in patients with benign prostatic hyperplasia", Korean J Urol, Vol. 52(4), pp. 265-268, 2011. DOI: http://dx.doi.org/10.4111/kju.2011.52.4.265
- M. Hamaguchi, T. Seno, A. Yamamoto, M. Kohno, M. Kadoya, H. Ishino, E. Ashihara, S. Kimura, Y. Tsubakimoto, H. Takata, T. Yoshikawa, T. Maekawa, Y. Kawahito, "Loxoprofen sodium, a non-selective NSAID, reduces atherosclerosis in mice by reducing inflammation", J Clin Biochem Nutr, Vol. 47(2), pp. 138-47, 2010. DOI: http://dx.doi.org/10.3164/jcbn.10-33
- M. Sekiguchi, M. Shirasaka, S. Konno, S. Kikuchi, "Analgesic effect of percutaneously absorbed non-steroidal anti-inflammatory drugs: an experimental study in a rat acute inflammation model", BMC Musculoskelet Disord, Vol. 9:15, 2008 (http://www.biomedcentral.com/1471-2474/9/15). https://doi.org/10.1186/1471-2474-9-15
- P. Loya, A. A. Kshatriya, M. N. Saraf, "Bioequivalence study of two brands of loxoprofen tablets in healthy volunteers", Int J PharmTech Research, Vol. 3(4), pp. 2038-2046, 2011.
- J. H. OH, M. H. Lee, L. M. Shaw, S. E. Lee, J. H. Park, J. S. Kang, "Pharmacokinetics and bioequivalence study of two brands of loxoprofen tablets in healthy volunteers", Arzneimittelforschung, Vol. 57(8), pp. 542-546, 2007.
- N. Yamakawa, S. Suemasu, H. Watanabe, K. Tahara, K. Tanaka, Y. Okamoto, M. Ohtsuka, T. Maruyama, T. Mizushima, "Comparison of pharmacokinetics between loxoprofen and its derivative with lower ulcerogenic activity, fluoro-loxoprofen", Drug Metab Pharmacokinet, Vol. 28(2), pp. 118-124, 2013. DOI: http://dx.doi.org/10.2133/dmpk.DMPK-12-RG-050
- M. J. Maltesen, M. van de Weert, H. Grohganz, "Design of experiments-based monitoring of critical quality attributes for the spray-drying process of insulin by NIR spectroscopy", AAPS PharmSciTech, Vol. 13(3), pp. 747-755, 2012. DOI: http://dx.doi.org/10.1208/s12249-012-9796-1
- K. Aaljoki, "Automated quality assurance of online NIR analysers", J Autom Methods Manag Chem, Vol. 2005(2), pp. 44-49, 2005. DOI: http://dx.doi.org/10.1155/JAMMC.2005.44
- C. Schaefer, C. Lecomte, D. Clicq, A. Merschaert, E. Norrant, F. Fotiadu, "On-line near infrared spectroscopy as a Process Analytical Technology (PAT) tool to control an industrial seeded API crystallization", J Pharm Biomed Anal, Vol. 83, pp. 194-201, 2013. DOI: http://dx.doi.org/10.1016/j.jpba.2013.05.015
- A. Burggraeve, A. F. Silva, T. van den Kerkhof, M. Hellings, C. Vervaet, J. P. Remon, Y. van der Heyden, T. De Beer, "Development of a fluid bed granulation process control strategy based on real-time process and product measurements", Talanta, Vol. 100, pp. 293-302, 2012. DOI: http://dx.doi.org/10.1016/j.talanta.2012.07.054
- S. H. Lee, J. H. Lee, S. Cho, S. H. Do, Y. A. Woo, "End point determination of blending process for trimebutine tablets using principle component analysis (PCA) and partial least squares (PLS) regression", Arch Pharm Res, Vol. 35(9), pp. 1599-1607, 2012. DOI: http://dx.doi.org/10.1007/s12272-012-0911-3
- J. G. Rosas, M. Blanco, J. M. Gonzalez, M. Alcala, "Real-time determination of critical quality attributes using near-infrared spectroscopy: a contribution for Process Analytical Technology (PAT)", Talanta, Vol. 97, pp. 163-170, 2012. DOI: http://dx.doi.org/10.1016/j.talanta.2012.04.012
- E. T. Skibsted, H. F. Boelens, J. A. Westerhuis, D. T. Witte, A. K. Smilde, "Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts", J Pharm Biomed Anal, Vol. 41(1), pp. 26-35, 2006. DOI: http://dx.doi.org/10.1016/j.jpba.2005.10.009
- Y. A. Woo, "Content uniformity in granules for aceclofenac controlled release (CR) tablets determined using near-infrared spectroscopy and wide area illumination (WAI) Raman spectroscopy", Arch Pharm Res, Vol. 35(2), pp. 351-358, 2012. DOI: http://dx.doi.org/10.1007/s12272-012-0216-6
- M. Blanco, A. Peguero, "Influence of physical factors on the accuracy of calibration models for NIR spectroscopy", J Pharm Biomed Anal, Vol. 52(1), pp. 59-65, 2010. DOI: http://dx.doi.org/10.1016/j.jpba.2009.12.009
- Y. H. Kim, B. R. Choi, H. Y. Baek, Y. S. Lee, "Quantification of icariin contents in Epimedium koreanum N. by using a Near Infrared Reflectance Spectroscopy", J Kor Medical Crop Sci, Vol. 10(5), pp. 340-343, 2002.
- J. U. Chun, K. S. Choi, "Nondestructive and rapid method for measurement of catechin contents in green tea products using NIRS", J Kor Tea Soc, Vol. 13(3), pp. 99-112, 2007.
- C. R. Park, A. Y. Kim, M. J. Lee, H. E. Lee, D. Y. Seo, S. Shin, Y. Choi, B. S. Kwon, K. H. Bang, H. K. Kang, C. K. Kim, S. K. Lee, G. J. Choi, "In-line monitoring of fluid-bed blending process for pharmaceutical powders using fiber optics probe and NIR spectroscopy", J Kor Pharm Sci, Vol. 39(1), pp. 29-36, 2009. DOI: http://dx.doi.org/10.4333/KPS.2009.39.1.029
- D. H. Kim, Y. A. Woo, H. J. Kim, "Quantitative analysis of indomethacin by the portable near-infrared (NIR) system", Yakhak Hoeji, Vol. 47(5), pp. 261-265, 2003.
- C. H. Cho, H. J. Kim, D. Y. Meang, S. H. Seo, J. H. Cho, "Quantitative analysis of taurine using near infrared spectrometry (NIRS)", Yakhak Hoeji, Vol. 42(6), pp. 545-551, 1998.
- J. H. Baek, N. Kang, Y. A. Woo, H. J. Kim, "Aqueous glucose solution measurement by three types NIR spectrometer", Yakhak Hoeji, Vol. 47(6), pp. 461-468, 2003.