Abstract

A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

Keywords

References

  1. W. J. Lee, B. S. Ahn, and Y. S. Park, "Radiation dose and image quality of low-dose protocol in chest CT: Comparison of standard-dose protocol", J. Radia. Protect., vol. 37, no. 2, pp. 84-89, 2012. https://doi.org/10.14407/jrp.2012.37.2.084
  2. J. S. Nam et. al., "Development of a needs based education course on the basics of radiation", J. Radia. Protect., vol. 38, no. 2, pp. 100-105, 2013. https://doi.org/10.14407/jrp.2013.38.2.100
  3. B. J. Park, "Analysis of public perception on radiation: with one year after fukushima nuclear accident", J. Radia. Protect., vol. 37, no. 1, pp. 1-9, 2012. https://doi.org/10.14407/jrp.2012.37.1.001
  4. C. K. Kim, J. I. Byun, J. S. Chae, H. T. Choi, S. W. Choi, D. J. Kim, Y. J. Kim, D. M. Lee, W. J. Park, S. A. Yim, and J. Y. Yun, "Radiological impact in Korea following the Fukushima nuclear accident", J. Environ. Radioact., vol. 111, no. 1, pp. 70-82, 2012. https://doi.org/10.1016/j.jenvrad.2011.10.018
  5. W. Zhang, E. Korpach, R. Berg, and K. Ungar, "Testing of an automatic outdoor gamma ambient dose-rate surveillance system in Tokyo and its calibration using measured deposition after the Fukushima nuclear accident", J. Environ. Radioact., http://dx.doi.org/10.1016/j.jenvrad.2012.12.011
  6. K. Hirose, "2011 Fukushima Dai-ichi nuclear power plant accident: summary of regional radioactive deposition monitoring results", J. Environ. Radioact., vol. 111, no. 1, pp. 13-17, 2012. https://doi.org/10.1016/j.jenvrad.2011.09.003
  7. N. Q. Long, Y. Truong, P. D. Hien, N. T. Binh, L. N. Sieu, T. V. Giap, anf N. T. Phan, "Atmospheric radionuclides from the Fukushima Dai-ichi nuclear reactor accident observed in Vietnam", J. Environ. Radioact., vol. 111, no. 1, pp. 53-58, 2012. https://doi.org/10.1016/j.jenvrad.2011.11.018
  8. P. Loaiza, V. Brudanin, F. Piquemal, J. L. Reyss, I. Stekl, G. Warot, and M. Zampaolo, "Air radioactivity levels following the Fukushima reactor accident measured at the Laboratoire Souterrain de Modane, France", J. Environ. Radioact., vol. 114, no. 1, pp. 66-70, 2012. https://doi.org/10.1016/j.jenvrad.2012.03.003
  9. A. Ioannidou, S. Manenti, L. Gini, and F. Groppi, "Fukushima fallout at Milano, Italy", J. Environ. Radioact., vol. 114, no. 1, pp. 119-125, 2012. https://doi.org/10.1016/j.jenvrad.2012.01.006
  10. G. F. Knoll, Radiation Detection and Measurement, John Wiley & Sons, Ann Arbor, pp. 144, 1999.
  11. http://www.detectors.saint-gobain.com/uploadedFiles/ SGdetectors/Documents/Product_Data_Sheets/BC400-404- 408-412-416-Data-Sheet.pdf(retrieved on Dec. 11, 2013)
  12. IAEA, "Absorbed dose determination in external beam radiotherapy", TRS-398, pp.101-104, 2000.
  13. J. K. Cheon, S. H. Kim, and H. J. Kim, "Crystal growth and scintillation properties of CsI:Gd", J. Sensor Sci. & Tech., vol. 21, no. 4, pp. 293-297, 2012. https://doi.org/10.5369/JSST.2012.21.4.293
  14. http://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html (retrieved on May. 14, 2013).