차동식 열감지기 설치기준 비교분석에 관한 연구

Differential temperature fire detector analysis of comparative study based on sensor installation

  • 투고 : 2014.10.20
  • 심사 : 2014.11.30
  • 발행 : 2014.12.31

초록

Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

키워드

참고문헌

  1. THE SFPE HAND BOOK of Fire Protection Engineering Chapter 4-1 Design of Detection System 4-3, 3 editions(2005), 4.1-4.44pp
  2. THE SFPE HAND BOOK of Fire Protection Engineering Chapte 2-2 Ceilling Jet Flows, 3editions(2005), 2.18-2.31pp
  3. Ho-Cheol Ryu, Byung-Kon Lee, Journal of KllS vol. 9, NO 1, March '1994. Operating Temperature and Time of Rise Heat Detector, 61-67pp
  4. Publisher of CYBER (2009), Combustion and fire dynamics, 58-70pp
  5. National fire safety code (2014), NFSC 203, NO 16, Automatic fire detection facility fire safety code
  6. Principles of Fire Behavier (1997), James G Quintiere, Chapte 3, Heat Transfer, 47-54pp
  7. Shi-kuk Kim, (2012) A Study on the Address Function of Automatic Fire Alarm System for Reliability Improvement, PhD thesis, HOSEO University Graduate School. 24-26pp
  8. dong-ha Park, (2010) A Study on the Automatic Fire Detector Spacing Calculation for Performance based Design, PhD thesis, University of Seoul Graduate School. 6-8pp
  9. Seung-cheol Sin, (2013), A Study on Differences in Test Methods of Domestic &Foreign Fire Detectors, Master's Thesis, GACHON University Graduate School of Industry & Environment. 29-34pp
  10. Hyun-dai Yuk, (2009) A Study on the Development of High Reliability Inspection Tester for the Field Test of Fire Detector, PhD thesis, HOSEO University Graduate School. 78-99pp
  11. Kap-chan Lee, (2001), (A) study on the improvement of reliability of automatic fire detecting system, Yonsei Graduate School of Industry, 18-27pp
  12. Ha-na Cha, (2008), A Study on the Problem and Improvement of the Fire Detector Test in the Field, Master's Thesis, HOSEO University Graduate School, 9-13pp