DOI QR코드

DOI QR Code

에어커튼형 주방 레인지후드의 배기 특성

Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain

  • 성순경 (가천대학교 설비소방공학과)
  • Sung, Sun-Kyung (Department of Building Mechanical System and Fire Protection Engineering)
  • 투고 : 2014.07.28
  • 심사 : 2014.10.08
  • 발행 : 2014.12.10

초록

There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

키워드

참고문헌

  1. Lim, K. B., Lee, K. S., and Lee, C. H., 2006, A Numerical Study on the Flow Characteristics of Kitchen Hood System, Korean Journal of Air-Conditioning and Refrigeration, Vol. 18, No. 4, pp. 359-369.
  2. Kim, B. G., Choi, H. G., Yong, H. T., and Lee, M. H., 2005, Horizontal Air-Jet Effect on the Natural Convection around a Range-Hood System, Korean Journal of Air-Conditioning and Refrigeration, Vol. 17, No. 4, pp. 333-340.
  3. Park, M. S., Lee, D. W., Kim, J. Y., and Lee, S. H., 2003, Experimental Study on Capture Efficiency of Kitchen Hood with Lower Make-up Air Supply Equipment, Proceedings of Sarek Summer Conference, pp. 1368-1372.
  4. Sohn, D. Y., Lim, J. H., Choi, Y. H., and Park, J. H., 2007, A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain, Korean Journal of Air-Conditioning and Refrigeration, Vol. 19, No. 4, pp. 321-327.
  5. Koo, N. Y., Lee, Y. K., and Yong, Y. S., 2002, An Experimental Study on the air curtain range hood interrupting the diffusion of polluted air, Proceedings of Sarek Winter Conference, pp. 382-387.
  6. Yuguo Li, and Angelo Delsante, 1996, Derivation of Capture Efficiency of Kitchen Range Hoods in a Confined Space, Building and Environment, Vol. 31, No. 5, pp. 461-468. https://doi.org/10.1016/0360-1323(96)00006-6
  7. Hayes, F. C. and Stoecker, W. F., 1969, Design data for air curtains, ASHRAE Transactions, Vol. 75, pp. 168-179.

피인용 문헌

  1. Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 vol.27, pp.7, 2015, https://doi.org/10.6110/KJACR.2015.27.7.380
  2. Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain vol.27, pp.9, 2015, https://doi.org/10.6110/KJACR.2015.27.9.468