References
- Ogaard B, Rolla G, Arends J. Orthodontic appliances and enamel demineralization. Part 1. Lesion development. Am J Orthod Dentofacial Orthop 1988;94:68-73 https://doi.org/10.1016/0889-5406(88)90453-2
- Zanarini M, Pazzi E, Bonetti S, Ruggeri O, Alessandri Bonetti G, Prati C. In vitro evaluation of the effects of a fluoride-releasing composite on enamel demineralization around brackets. Prog Orthod 2012;13:10-6. https://doi.org/10.1016/j.pio.2011.04.004
- Chapman JA, Roberts WE, Eckert GJ, Kula KS, Gonzalez- Cabezas C. Risk factors for incidence and severity of white spot lesions during treatment with fixed orthodontic appliances. Am J Orthod Dentofacial Orthop 2010;138:188-94. https://doi.org/10.1016/j.ajodo.2008.10.019
- Atack NE, Sandy JR, Addy M. Periodontal and microbiological changes associated with the placement of orthodontic appliances. A review. J Periodontol 1996;67:78-85. https://doi.org/10.1902/jop.1996.67.2.78
- Petti S, Barbato E, Simonetti D'Arca A. Effect of orthodontic therapy with fixed and removable appliances on oral microbiota: a six-month longitudinal study. New Microbiol 1997;20:55-62.
- Ristic M, Vlahovic Svabic M, Sasic M, Zelic O. Clinical and microbiological effects of fixed orthodontic appliances on periodontal tissues in adolescents. Orthod Craniofac Res 2007;10:187-95. https://doi.org/10.1111/j.1601-6343.2007.00396.x
- Park SY, Cha JY, Kim KN, Hwang CJ. The effect of casein phosphopeptide amorphous calciumphosphate on the in vitro shear bond strength of orthodontic brackets. Korean J Orthod 2013;43:23-8. https://doi.org/10.4041/kjod.2013.43.1.23
- Gwinnett AJ, Ceen RF. Plaque distribution on bonded brackets: a scanning microscope study. Am J Orthod 1979;75:667-77. https://doi.org/10.1016/0002-9416(79)90098-8
- Checchi L, Nobili A. The importance of hygiene control in orthodontics. Prev Assist Dent 1988;14: 35-7.
- Gwinnett AJ, Ceen RF. Plaque distribution on bonded brackets: a scanning microscope study. Am J Orthod 1979;75:667-77. https://doi.org/10.1016/0002-9416(79)90098-8
- Sukontapatipark W, el-Agroudi MA, Selliseth NJ, Thunold K, Selvig KA. Bacterial colonization associated with fixed orthodontic appliances. A scanning electron microscopy study. Eur J Orthod 2001;23: 475-84. https://doi.org/10.1093/ejo/23.5.475
- Olin PS. Effect of prolonged ultrasonic instrumentation on the retention of cemented cast crowns. J Prosthet Dent 1990;64:563-5. https://doi.org/10.1016/0022-3913(90)90128-Y
- Krell KV, Courey JM, Bishara SE. Orthodontic bracket removal using conventional and ultrasonic debonding techniques, enamel loss, and time requirements. Am J Orthod Dentofacial Orthop 1993; 103:258-66. https://doi.org/10.1016/0889-5406(93)70007-B
- Boyer DB, Engelhardt G, Bishara SE. Debonding orthodontic ceramic brackets by ultrasonic instrumentation. Am J Orthod Dentofacial Orthop 1995; 108:262-6. https://doi.org/10.1016/S0889-5406(95)70019-6
- Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part I. Background and methods. Am J Orthod Dentofacial Orthop 1990;98:145-53. https://doi.org/10.1016/0889-5406(90)70008-Z
- Walmsley AD, Jones PA, Hullah W, Harrington E. Ultrasonic debonding of composite-retained restorations. Br Dent J 1989;166:290-4. https://doi.org/10.1038/sj.bdj.4806798
- Giulio AB, Matteo Z, Serena IP, Silvia M, Luigi C. In vitro evaluation of casein phosphopeptideamorphous calcium phosphate (CPP-ACP) effect on stripped enamel surfaces. A SEM investigation. J Dent 2009;37:228-32. https://doi.org/10.1016/j.jdent.2008.11.015
- International Organization for Standardization. ISO/TS 11405:2003. Dental materials - Testing of adhesion to tooth structure. ISO: 2003 [cited Apr 23, 2013]. Available from: http://www.iso.org/iso/ home/store/catalogue_tc/catalogue_detail.htm? csnumber=31486.
- Alessandri Bonetti G, Zanarini M, Incerti Parenti S, Lattuca M, Marchionni S, Gatto MR. Evaluation of enamel surfaces after bracket debonding: an invivo study with scanning electron microscopy. Am J Orthod Dentofacial Orthop 2011;140:696-702. https://doi.org/10.1016/j.ajodo.2011.02.027
- Vicente A, Bravo LA, Romero M, Ortiz AJ, Canteras M. Adhesion promoters: effects on the bond strength of brackets. Am J Dent 2005;18:323-6.
- Montasser MA, Drummond JL. Reliability of the adhesive remnant index score system with different magnifications. Angle Orthod 2009;79:773-6. https://doi.org/10.2319/080108-398.1
- Artun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. Am J Orthod 1984;85:333-40. https://doi.org/10.1016/0002-9416(84)90190-8
- Pont HB, Ozcan M, Bagis B, Ren Y. Loss of surface enamel after bracket debonding: an in-vivo and exvivo evaluation. Am J Orthod Dentofacial Orthop 2010;138:387.e1-9; discussion 387-9. https://doi.org/10.1016/j.ajodo.2010.05.012
- Muller P, Guggenheim B, Attin T, Marlinghaus E, Schmidlin PR. Potential of shock waves to remove calculus and biofilm. Clin Oral Investig 2011;15:959-65. https://doi.org/10.1007/s00784-010-0462-2
- Chapple IL, Walmsley AD, Saxby MS, Moscrop H. Effect of instrument power setting during ultrasonic scaling upon treatment outcome. J Periodontol 1995;66:756-60. https://doi.org/10.1902/jop.1995.66.9.756
- Reynolds IR. A review of direct orthodontic bonding. Br J Orthod 1975;2:171-80
- Lombardo L, Kaplan A, Lapenta R, Bratti E, Pera C, Scuzzo G, et al. A comparative study of lingual bracket bond strength. Orthodontics (Chic.) 2011;12: 178-87.
- Arabaci T, Cicek Y, Canakci CF. Sonic and ultrasonic scalers in periodontal treatment: a review. Int J Dent Hyg 2007;5:2-12. https://doi.org/10.1111/j.1601-5037.2007.00217.x
- Flemmig TF, Petersilka GJ, Mehl A, Hickel R, Klaiber B. The effect of working parameters on root substance removal using a piezoelectric ultrasonic scaler in vitro. J Clin Periodontol 1998;25:158-63. https://doi.org/10.1111/j.1600-051X.1998.tb02422.x
Cited by
- Dental Hygiene and Orthodontics: Effect of Ultrasonic Instrumentation on Bonding Efficacy of Different Lingual Orthodontic Brackets vol.2017, pp.None, 2014, https://doi.org/10.1155/2017/3714651
- Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures vol.15, pp.2, 2014, https://doi.org/10.3892/etm.2017.5630