References
- Torres MG, Campos PS, Segundo NP, Navarro M, Crusoe-Rebello I. Accuracy of linear measurements in cone beam computed tomography with different voxel sizes. Implant Dent 2012; 21: 150-5. https://doi.org/10.1097/ID.0b013e31824bf93c
- Cavalcanti MG, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol 2004; 33: 170-6. https://doi.org/10.1259/dmfr/13603271
- Ziegler CM, Woertche R, Brief J, Hassfeld S. Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 2002; 31: 126-30. https://doi.org/10.1038/sj.dmfr.4600680
- Guerrero ME, Jacobs R, Loubele M, Schutyser F, Suetens P, van Steenberghe D. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin Oral Investig 2006; 10: 1-7. https://doi.org/10.1007/s00784-005-0031-2
- Kau CH, Richmond S, Palomo JM, Hans MG. Three-dimensional cone beam computerized tomography in orthodontics. J Orthod 2005; 32: 282-93. https://doi.org/10.1179/146531205225021285
- Yamamoto K, Ueno K, Seo K, Shinohara D. Development of dento-maxillofacial cone beam X-ray computed tomography system. Orthod Craniofac Res 2003; 6 Suppl 1: 160-2. https://doi.org/10.1034/j.1600-0544.2003.249.x
- Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006; 72: 75-80.
- Kumar V, Ludlow JB, Mol A, Cevidanes L. Comparison of conventional and cone beam CT synthesized cephalograms. Dentomaxillofac Radiol 2007; 36: 263-9. https://doi.org/10.1259/dmfr/98032356
- Li T, MacDonald D. Osseo integrated implants. In: MacDonald D. Oral and maxillofacial radiology: a diagnostic approach. Chichester: Wiley-Blackwell; 2011. p. 296-8.
- Boas FE, Fleischmann D. CT artifact: cause and reduction techniques. Imaging Med 2012; 4: 229-40. https://doi.org/10.2217/iim.12.13
- Ganguly R, Ruprecht A, Vincent S, Hellstein J, Timmons S, Qian F. Accuracy of linear measurement in the Galileos cone beam computed tomography under simulated clinical conditions. Dentomaxillofac Radiol 2011; 40: 299-305. https://doi.org/10.1259/dmfr/72117593
- Sheikhi M, Ghorbanizadeh S, Abdinian M, Goroohi H, Badrian H. Accuracy of linear measurements of Galileos cone beam computed tomography in normal and different head positions. Int J Dent 2012; 2012: 214954.
- Tomasi C, Bressan E, Corazza B, Mazzoleni S, Stellini E, Lith A. Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations. Dentomaxillofac Radiol 2011; 40: 244-50. https://doi.org/10.1259/dmfr/17432330
- Bashizadeh Fakhar H, Abbaszadeh A. Effect of mandibular plane angle on image dimensions in linear tomography. J Dent Med 2011; 24: 42-9.
- Hassan B, van der Stelt P, Sanderink G. Accuracy of threedimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position. Eur J Orthod 2009; 31: 129-34. https://doi.org/10.1093/ejo/cjn088
- Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from conebeam computed tomography. Am J Orthod Dentofacial Orthop 2004; 132: 550-60.
- Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 103: 534-42. https://doi.org/10.1016/j.tripleo.2006.04.008
- Moshfeghi M, Tavakoli MA, Hosseini ET, Hosseini AT, Hosseini IT. Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG). Dent Res J (Isfahan) 2012; 9: S57-62.
Cited by
- Effect of Head Position on Maxillofacial Transverse Measurements Made on the Skull and Cone Beam Computed Tomography Scans vol.27, pp.5, 2016, https://doi.org/10.1590/0103-6440201601166
- The Use of Cone-Beam Computed Tomography in Management of Patients Requiring Dental Implants: An American Academy of Periodontology Best Evidence Review vol.88, pp.10, 2014, https://doi.org/10.1902/jop.2017.160548
- Detecting the effect of bisphosphonates during osteoporosis treatment on jawbones using multidetector computed tomography: The OSTEOSYR project vol.9, pp.3, 2014, https://doi.org/10.1111/jicd.12332
- Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review vol.29, pp.16, 2014, https://doi.org/10.1111/clr.13142
- Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning vol.10, pp.None, 2014, https://doi.org/10.25259/jcis_150_2019
- The dimensions of the facial alveolar bone at tooth sites with local pathologies: a retrospective cone-beam CT analysis vol.24, pp.4, 2014, https://doi.org/10.1007/s00784-019-03057-x
- Influence of Cone-beam CT Volume Orientation on the Proximity of Maxillary Sinus to the Alveolar Crest at Dental Implant Sites vol.13, pp.1, 2014, https://doi.org/10.5005/jp-journals-10015-1883
- Is the panoramic radiography sufficient for detecting the relationship of the posterior maxillary teeth with maxillary sinus floor? A retrospective study comparative with cone-beam computed tomography vol.10, pp.2, 2021, https://doi.org/10.4103/ijhas.ijhas_281_20
- Implant-to-root dimensions projected by panoramic radiographs inthe maxillary canine-premolar region: implications for dental implant treatment vol.21, pp.1, 2014, https://doi.org/10.1186/s12880-021-00567-7
- Panoramic prediction equations to estimate implant- to-mandibular canal dimensions in the mandibular posterior region: implications for dental implant treatment vol.17, pp.1, 2014, https://doi.org/10.1186/s13005-021-00270-6