References
- Rinkel, G., Djibuti, M., Algra, A. and van Gijn, J., 1998, "Prevalence and Risk of Rupture of Intracranial Aneurysms: A Systematic Review," Stroke, Vol. 29, pp. 251-256. https://doi.org/10.1161/01.STR.29.1.251
- Wiebers, D., Whisnant, J., Huston, J., Meissner, I., Brown, R., Piepgras, D., Forbes, G. and Thielen, K., et al., 2003, "Unruptured Intracranial Aneurysms: Natural History, Clinical Outcome, and Risks of Surgical and Endovascular Treatment," Lancet, Vol. 362, pp.103-110. https://doi.org/10.1016/S0140-6736(03)13860-3
- Ishibashi, T., Murayama, Y., Urashima, M., Saguchi, T., Ebara, M., Arakawa, H., Irie, K., Takao, H. and Abe, T., 2009, "Unruptured Intracranial Aneurysms: Incidence of Rupture and Risk Factors," Stroke, Vol. 40, pp. 313-316. https://doi.org/10.1161/STROKEAHA.108.521674
- Valencia, A., Guzmán, A., Finol, E. and Amon, C., 2006, "Blood Flow Dynamics in Saccular Aneurysm Models of the Basilar Artery," J. Biomech. Eng. Vol. 128, pp. 516-526 https://doi.org/10.1115/1.2205377
- Steinman, D., Milner, J., Norley, C., Lownie, S. and Holdsworth, D., 2003, "Image-Based Computational Simulation of Flow Dynamics in a Giant Intracranial Aneurysm," AJNR Am. J. Neuroradiol., Vol. 24, pp. 559-566.
- Sforza, D., Putman, C., Scrivano, E., Lylyk, P. and Cebral, J., 2010, "Blood-Flow Characteristics in a Terminal Basilar Tip Aneurysm Prior to Its Fatal Rupture," AJNR Am. J. Neuroradiol., Vol. 31, pp. 1127-1131. https://doi.org/10.3174/ajnr.A2021
- Park, J.S. and Lee, S.W., 2011, "Effects of non-Newtonian Fluid Model in Cerebral Saccular Aneurysms," J. Comp. Fluids Eng., Vol. 14(3), pp. 81-87.
- Lee, S.W., 2012, "On the Effect of Shear-Thinning Rheology on Hemodynamic Characteristics in Basilar Tip Aneurysms with Implication of Two Distinct Flow Patterns," JMST, Vol. 26(10), pp. 3125-3132.
- Kim, M., Taulbee, D.B., Tremmel, M. and Meng, H., 2008, "Comparison of Two Stents in Modifying Cerebral Aneurysm Hemodynamics," Ann. Biomed. Eng., Vol. 36(5), pp. 726-741. https://doi.org/10.1007/s10439-008-9449-4
- Liou, T.M. and Li, Y.C., 2008, "Effects of Stent Porosity on Hemodynamics in a Sidewall Aneurysm Model," J Biomech., Vol. 41, pp. 1174-1183. https://doi.org/10.1016/j.jbiomech.2008.01.025
- Kim, Y.H., Xu, X. and Lee, J.S., 2010, "The Effect of Stent Porosity and Strut Shape on Saccular Aneurysm and Its Numerical Analysis with Lattice Boltzmann Method," Ann Biomed Eng. Vol. 38, pp. 2274-2292 https://doi.org/10.1007/s10439-010-9994-5
- Yu, C. H., Matsumoto, K., Shida, S., Kim, D. J. and Ohta, M., 2012, "A Steady Flow Analysis on a Cerebal Aneurysm Model with Several Stents for New Stent Design Using PIV," JMST, Vol. 26, No. 5, pp. 1333-1340.
- Ethier, C., Prakash, S., Steinman, D., Leask, R., Couch, G. and Ojha, M., 1999, "Steady Flow Separation Patterns in a 45 Degree Junction," J. Fluid Mech., Vol. 411, pp. 1-38.
- Minev, P. and Ethier, 1998, "A Characteristic/ Finite Element Algorithm for the 3-D Navier- Stokes Equations Using Unstructured Grids," Comp. Meth. App. Mech. Eng., Vol. 178, No. 1-2, pp. 39-50. https://doi.org/10.1016/S0045-7825(99)00003-1