DOI QR코드

DOI QR Code

DETECTION OF ODSCC IN SG TUBES DEPENDING ON THE SIZE OF THE CRACK AND ON THE PRESENCE OF SLUDGE DEPOSITS

  • Chung, Hansub (Korea Hydro Nuclear Power - Central Research Institute) ;
  • Kim, Hong-Deok (Korea Hydro Nuclear Power - Central Research Institute) ;
  • Kang, Yong-Seok (Korea Hydro Nuclear Power - Central Research Institute) ;
  • Lee, Jae-Gon (Korea Hydro Nuclear Power - Central Research Institute) ;
  • Nam, Minwoo (Korea Hydro Nuclear Power - Central Research Institute)
  • Received : 2014.06.30
  • Accepted : 2014.08.09
  • Published : 2014.12.25

Abstract

It was discovered in a Korean PWR that an extensive number of very short and shallow cracks in the SG tubes were undetectable by eddy current in-service-inspection because of the masking effect of sludge deposits. Axial stress corrosion cracks at the outside diameter of the steam generator tubes near the line contacts with the tube support plates are the major concern among the six identical Korean nuclear power plants having CE-type steam generators with Alloy 600 high temperature mill annealed tubes, HU3&4 and HB3~6. The tubes in HB3&4 have a less susceptible microstructure so that the onset of ODSCC was substantially delayed compared to HU3&4 whose tubes are most susceptible to ODSCC among the six units. The numbers of cracks detected by the eddy current inspection jumped drastically after the steam generators of HB4 were chemically cleaned. The purpose of the chemical cleaning was to mitigate stress corrosion cracking by removing the heavy sludge deposit, since a corrosive environment is formed in the occluded region under the sludge deposit. SGCC also enhances the detection capability of the eddy current inspection at the same time. Measurement of the size of each crack using the motorized rotating pancake coil probe indicated that the cracks in HB4 were shorter and substantially shallower than the cracks in HU3&4. It is believed that the cracks were shorter and shallower because the microstructure of the tubes in HB4 is less susceptible to ODSCC. It was readily understood from the size distribution of the cracks and the quantitative information available on the probability of detection that most cracks in HB4 had been undetected until the steam generators were chemically cleaned.

Keywords

References

  1. Hansub Chung et al., NET Vol.45 No.4 August 2013
  2. Pressurized Water Reactor Hideout Return Sourcebook Prediction of Crevice Solution Chemistry in PWR Steam Generators, Electric Power Research Institute, Technical Report 1014985 (December 2007)
  3. Pressurized Water Reactor Secondary Water Chemistry Guidelines - Revision 7, Electric Power Research Institute Technical Report 101655 (February 2009)
  4. ATHOS/SGAP, Version 3.1, Analysis of the Thermal Hydraulics of a Steam Generator/Steam Generator Analysis Package, Electric Power Research Institute, Software 1016564 (November 2008)
  5. The Development of Technology for Measuring the Corrosion Product Scale on the Steam Generator Tubes, Korea Hydro Nuclear Power, Technical Report E09NJ10 (December 2012)
  6. Korea Root Cause Analysis of Ulchin Unit 4 SG Tube Cracking, Hydro Nuclear Power, Technical Report 2012-50003339-056TR (August 2012)
  7. ASTM E 1928 - 07, Standard Practice for Estimating the Approximate Residual Circumferential Stress in Straight Thin-walled Tubing
  8. Prevey, Paul S. "X-ray Diffraction Residual Stress Techniques, Metals Handbook. 10th Vol. Metals Handbook, American Society for Metals, 1986, 380-392
  9. Steam Generator Degradation Database, Web service by Electric Power Research Institute
  10. Kazutoshi FUJIWARA et al., J. NUCLEAR SCIENCE and TECHNOLOGY Vol.41 No.1 (January 2004)
  11. Hirotaka KAWAMURA et al, J. NUCLEAR SCIENCE and TECHNOLOGY Vol.42 No.3 (March 2005)
  12. Operational assessments of steam generators, Korea Hydro Nuclear Power, internal reports (2012-2014)
  13. Jae Bong Lee, Jai Hak Park, Hong Deok Kim, and Hansub Chung, International J. Pressure Vessel and Piping 87 (2010) 46-51 https://doi.org/10.1016/j.ijpvp.2009.11.005
  14. An ECT Round Robin Program Using Degraded Tubes from a Replaced Steam Generator of Kori Unit One, Korea Electric Power Research Institute, Technical Report 05NE04-1.R2006 (July 2008)