DOI QR코드

DOI QR Code

Transcatheter Aortic Valve Implantation in a Patient with Previous Mitral Valve Replacement

  • Moon, Sung Woo (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Ko, Young-Guk (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Hong, Geu-Ru (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Lee, Sak (Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Chang, Byung-Chul (Department of Thoracic and Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Shim, Jae-Kwang (Department of Anesthesiology and Pain Medicine, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Kwak, Young-Ran (Department of Anesthesiology and Pain Medicine, Severance Cardiovascular Hospital, Yonsei University College of Medicine) ;
  • Hong, Myeong-Ki (Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine)
  • 투고 : 2013.07.17
  • 심사 : 2013.10.08
  • 발행 : 2014.05.30

초록

Transcatheter aortic valve implantation (TAVI) has shown favorable outcomes in patients with severe symptomatic aortic valve stenosis who are at high surgical risk or are unsuitable candidates for open heart surgery. However, concerns exist over treating patients who have previously undergone mitral valve surgery due to the potential interference between the mitral prosthetic valve or ring and the TAVI device. In this case report, we present a patient with symptomatic severe aortic stenosis and previous mechanical mitral valve replacement who was successfully treated with TAVI using a CoreValve.

키워드

참고문헌

  1. Cribier A, Eltchaninoff H, Tron C, et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol 2006;47:1214-23. https://doi.org/10.1016/j.jacc.2006.01.049
  2. Grube E, Buellesfeld L, Mueller R, et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ Cardiovasc Interv 2008; 1:167-75. https://doi.org/10.1161/CIRCINTERVENTIONS.108.819839
  3. Kim IS, Ko YG, Shin S, et al. The first case of successful transcatheter aortic valve implantation using CoreValve in Korea. Korean Circ J 2012; 42:788-91. https://doi.org/10.4070/kcj.2012.42.11.788
  4. Akins CW, Buckley MJ, Daggett WM, et al. Risk of reoperative valve replacement for failed mitral and aortic bioprostheses. Ann Thorac Surg 1998;65:1545-51; discussion 1551-2. https://doi.org/10.1016/S0003-4975(98)00301-4
  5. Jamieson WR, Burr LH, Miyagishima RT, et al. Re-operation for bioprosthetic aortic structural failure - risk assessment. Eur J Cardiothorac Surg 2003;24:873-8. https://doi.org/10.1016/S1010-7940(03)00566-9
  6. Soon JL, Ye J, Lichtenstein SV, Wood D, Webb JG, Cheung A. Transapical transcatheter aortic valve implantation in the presence of a mitral prosthesis. J Am Coll Cardiol 2011;58:715-21. https://doi.org/10.1016/j.jacc.2011.04.023
  7. Petronio AS, De Carlo M, Bedogni F, et al. Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system. Circ Cardiovasc Interv 2010;3:359-66. https://doi.org/10.1161/CIRCINTERVENTIONS.109.930453
  8. Antman EM. Implications of contemporary clinical trials series: the Placement of Aortic Transcatheter Valve trial (PARTNER). Circulation 2012;125:3054. https://doi.org/10.1161/CIRCULATIONAHA.112.121251
  9. Rodes-Cabau J, Dumont E, Miro S, et al. Apical aortic valve implantation in a patient with a mechanical valve prosthesis in mitral position. Circ Cardiovasc Interv 2008;1:233. https://doi.org/10.1161/CIRCINTERVENTIONS.108.813592
  10. Bruschi G, De Marco F, Oreglia J, et al. Percutaneous implantation of CoreValve aortic prostheses in patients with a mechanical mitral valve. Ann Thorac Surg 2009;88:e50-2. https://doi.org/10.1016/j.athoracsur.2009.07.028
  11. Bruschi G, De Marco F, Barosi A, et al. Self-expandable transcatheter aortic valve implantation for aortic stenosis after mitral valve surgery. Interact Cardiovasc Thorac Surg 2013;17:90-5. https://doi.org/10.1093/icvts/ivt086

피인용 문헌

  1. Sutureless 3f Enable valve implantation concomitant with mitral valve surgery. vol.21, pp.2, 2014, https://doi.org/10.1093/icvts/ivv110
  2. Previously implanted mitral surgical prosthesis in patients undergoing transcatheter aortic valve implantation: Procedural outcome and morphologic assessment using multidetector computed tomography vol.14, pp.12, 2014, https://doi.org/10.1371/journal.pone.0226512
  3. Transcatheter Aortic Valve Replacement After Prior Mitral Valve Surgery: Results From the Transcatheter Valve Therapy Registry vol.109, pp.6, 2014, https://doi.org/10.1016/j.athoracsur.2019.08.113