DOI QR코드

DOI QR Code

Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin (Department of Architectural Engineering Chungnam National University) ;
  • Li, Rui (Department of Architectural Engineering Chungnam National University) ;
  • Jung, Heetaek (3D Engineering Co., Ltd.) ;
  • Chen, Liuyi (Department of Architectural Engineering Chungnam National University) ;
  • Oh, Kyunghwan (Engineering & Construction Group, Samsung C&T Corporation)
  • Received : 2013.03.18
  • Accepted : 2013.08.01
  • Published : 2013.11.25

Abstract

The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

Keywords

References

  1. AISC (2010), Seismic Provision for Structural Steel Building, American Institute of Steel Structure, Chicago, IL, USA.
  2. Chen, C.C., Lin, C.C. and Lin, C.H. (2006), "Ductile moment connections used in steel column-tree moment-resisting frames", J. Constr. Steel Res., 62(8), 793-801. https://doi.org/10.1016/j.jcsr.2005.11.012
  3. Chen, J., Su, M., Shen L., Cai, Y. and Guo, H. (2007), "Experimental study on steel moment resistant frame connections with welded flange plates", J. Build. Struct., 2007(3), 1-7.
  4. Farrokh, T., Danesh, F.A. and Eshghi, S. (2010), "The structural detailing effect on seismic behavior of steel moment resisting connections", Struct. Eng. Mech., Int. J., 35(5), 617-630 https://doi.org/10.12989/sem.2010.35.5.617
  5. FEMA (2000), "Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings:FEMA-350", SAC Joint Venture, Richmond, Caliph, USA.
  6. Gilton, C.S. and Uang, C.-M. (2002), "Cyclic response and design recommendations of weak-axis reduced beam section moment connections", J. Struct. Eng. ASCE, 128(4), 452-463. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(452)
  7. Girao Coelho, A.M. and Bijlaard, F.S.K. (2007), "Experimental behavior of high strength steel end-plate connections", J. Constr. Steel Res., 63(9), 1228-1240. https://doi.org/10.1016/j.jcsr.2006.11.010
  8. Han, S.W., Kwon, G.U. and Moon, K.H. (2007), "Cyclic behaviour of post-Northridge WUF-B connections", J. Constr. Steel Res., 63(3), 365-374. https://doi.org/10.1016/j.jcsr.2006.05.003
  9. Kim, S.D., Kim, S.S. and Ju, Y.K. (2008), "Strength evaluation of beam-column connection in the weak axis of H-shaped column", Eng. Struct., 30(6), 1699-1710. https://doi.org/10.1016/j.engstruct.2007.11.008
  10. Latour, M. and Rizzano, G. (2011), "Experimental behavior and mechanical modeling of dissipative t-stub connections", J. Struct. Eng., 138(2), 170-182.
  11. Latour, M., Piluso, V. and Rizzano, G. (2011), "Experimental analysis of innovative dissipative bolted double split tee beam-to-column connections", Steel Construct., 4(2), 53-64. https://doi.org/10.1002/stco.201110009
  12. Schneider, S.P. and Teeraparbwong, I. (2002), "Inelastic behavior of bolted flange plate connections", J. Struct. Eng., 128(4), 492-500. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(492)
  13. Venti, M. and Engelhardt, M.D. (2000), "Test of a free flange connection with a composite floor slab", SAC Background Document SAC/BD-00/18, SAC Joint Venture, Richmond, CA, USA.

Cited by

  1. Cyclic test for beam-to-column abnormal joints in steel moment-resisting frames vol.18, pp.5, 2015, https://doi.org/10.12989/scs.2015.18.5.1177
  2. Cyclic Testing of Bolted Flange Plate and Double Split Tee Type Weak-Axis Steel Moment Connections vol.204-208, pp.1662-7482, 2012, https://doi.org/10.4028/www.scientific.net/AMM.204-208.2913
  3. Cyclic Testing of Welded Free Flange Type and Welded Flange Plate Type Weak-Axis Steel Moment Connections vol.204-208, pp.1662-7482, 2012, https://doi.org/10.4028/www.scientific.net/AMM.204-208.2922
  4. Modification of pre-Kobe column-tree moment resisting connection vol.19, pp.2, 2013, https://doi.org/10.1007/s42107-018-0019-2
  5. Experiment and bearing capacity analyses of dual-lintel column joints in Chinese traditional style buildings vol.28, pp.5, 2013, https://doi.org/10.12989/scs.2018.28.5.641