DOI QR코드

DOI QR Code

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

  • Kim, Myeong Jin (Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea) ;
  • Lim, Yong Cheol (Department of Neurosurgery, Ajou University School of Medicine) ;
  • Oh, Se-Yang (Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea) ;
  • Kim, Byung Moon (Department of Radiology, Severance Hospital, Yonsei University College of Medicine) ;
  • Kim, Bum-Soo (Department of Radiology, Seoul St. Mary's Hospital, The Catholic University of Korea) ;
  • Shin, Yong Sam (Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea)
  • 투고 : 2012.11.26
  • 심사 : 2013.07.08
  • 발행 : 2013.07.28

초록

Objective : The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. Methods : From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. Results : Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was $5.0{\pm}8.7$ (mean${\pm}$SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was $2.1{\pm}5.4$ (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. Conclusion : The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

키워드

참고문헌

  1. Albayram S, Selcuk H, Kara B, Bozdag E, Uzma O, Kocer N, et al. : Thromboembolic events associated with balloon-assisted coil embolization : evaluation with diffusion-weighted MR imaging. AJNR Am J Neuroradiol 25 : 1768-1777, 2004
  2. Bendszus M, Koltzenburg M, Burger R, Warmuth-Metz M, Hofmann E, Solymosi L : Silent embolism in diagnostic cerebral angiography and neurointerventional procedures : a prospective study. Lancet 354 : 1594-1597, 1999 https://doi.org/10.1016/S0140-6736(99)07083-X
  3. Debrun GM, Aletich VA, Kehrli P, Misra M, Ausman JI, Charbel F : Selection of cerebral aneurysms for treatment using Guglielmi detachable coils : the preliminary University of Illinois at Chicago experience. Neurosurgery 43 : 1281-1295; discussion 1296-1297, 1998
  4. Han MH, Kwon OK, Yoon CJ, Kwon BJ, Cha SH, Chang KH : Gas generation and clot formation during electrolytic detachment of Guglielmi detachable coils : in vitro observations and animal experiment. AJNR Am J Neuroradiol 24 : 539-544, 2003
  5. Hwang G, Park H, Bang JS, Jin SC, Kim BC, Oh CW, et al. : Comparison of 2-year angiographic outcomes of stent- and nonstent-assisted coil embolization in unruptured aneurysms with an unfavorable configuration for coiling. AJNR Am J Neuroradiol 32 : 1707-1710, 2011 https://doi.org/10.3174/ajnr.A2592
  6. Klotzsch C, Nahser HC, Henkes H, Kühne D, Berlit P : Detection of microemboli distal to cerebral aneurysms before and after therapeutic embolization. AJNR Am J Neuroradiol 19 : 1315-1318, 1998
  7. Koebbe CJ, Veznedaroglu E, Jabbour P, Rosenwasser RH : Endovascular management of intracranial aneurysms : current experience and future advances. Neurosurgery 59 (5 Suppl 3) : S93-S102; discussion S3-S13, 2006
  8. Lee DH, Hwang SM, Lim OK, Kim JK : In vitro observation of air bubbles during delivery of various detachable aneurysm embolization coils. Korean J Radiol 13 : 412-416, 2012 https://doi.org/10.3348/kjr.2012.13.4.412
  9. Moret J, Cognard C, Weill A, Castaings L, Rey A : The "Remodelling Technique" in the Treatment of Wide Neck Intracranial Aneurysms. Angiographic Results and Clinical Follow-up in 56 Cases. Interv Neuroradiol 3 : 21-35, 1997 https://doi.org/10.1177/159101999700300103
  10. Murayama Y, Nien YL, Duckwiler G, Gobin YP, Jahan R, Frazee J, et al. : Guglielmi detachable coil embolization of cerebral aneurysms : 11 years' experience. J Neurosurg 98 : 959-966, 2003 https://doi.org/10.3171/jns.2003.98.5.0959
  11. Murayama Y, Vinuela F, Duckwiler GR, Gobin YP, Guglielmi G : Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system. J Neurosurg 90 : 207-214, 1999 https://doi.org/10.3171/jns.1999.90.2.0207
  12. Nelson PK, Levy DI : Balloon-assisted coil embolization of wide-necked aneurysms of the internal carotid artery : medium-term angiographic and clinical follow-up in 22 patients. AJNR Am J Neuroradiol 22 : 19-26, 2001
  13. Padolecchia R, Guglielmi G, Puglioli M, Castagna M, Nardini V, Collavoli PL, et al. : Role of electrothrombosis in aneurysm treatment with Guglielmi detachable coils : an in vitro scanning electron microscopic study. AJNR Am J Neuroradiol 22 : 1757-1760, 2001
  14. Pelz DM, Lownie SP, Fox AJ : Thromboembolic events associated with the treatment of cerebral aneurysms with Guglielmi detachable coils. AJNR Am J Neuroradiol 19 : 1541-1547, 1998
  15. Qureshi AI, Suri MF, Khan J, Kim SH, Fessler RD, Ringer AJ, et al. : Endovascular treatment of intracranial aneurysms by using Guglielmi detachable coils in awake patients : safety and feasibility. J Neurosurg 94 : 880-885, 2001 https://doi.org/10.3171/jns.2001.94.6.0880
  16. Rordorf G, Bellon RJ, Budzik RE Jr, Farkas J, Reinking GF, Pergolizzi RS, et al. : Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils : prospective study applying diffusion-weighted imaging. AJNR Am J Neuroradiol 22 : 5-10, 2001
  17. Sakai H, Sakai N, Nakahara I, Shimozuru T, Higashi T, Takahashi JC, et al. : Embolic Complications of Endovascular Surgery for Cerebrovascular Diseases. Evaluation with Diffusion-Weighted MR Imaging. Interv Neuroradiol 6 Suppl 1 : 223-226, 2000
  18. Soeda A, Sakai N, Sakai H, Iihara K, Yamada N, Imakita S, et al. : Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms : evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging. AJNR Am J Neuroradiol 24 : 127-132, 2003
  19. Vinuela F, Duckwiler G, Mawad M : Guglielmi detachable coil embolization of acute intracranial aneurysm : perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86 : 475-482, 1997 https://doi.org/10.3171/jns.1997.86.3.0475

피인용 문헌

  1. Microembolism after endovascular coiling of unruptured cerebral aneurysms: incidence and risk factors vol.124, pp.3, 2013, https://doi.org/10.3171/2015.3.jns142835
  2. Early diffusion-weighted MRI lesions after treatment of unruptured intracranial aneurysms: a prospective study vol.126, pp.4, 2017, https://doi.org/10.3171/2016.2.jns152456
  3. Early diffusion-weighted MRI lesions after treatment of unruptured intracranial aneurysms: a prospective study vol.126, pp.4, 2017, https://doi.org/10.3171/2016.2.jns152456
  4. Diffusion-Weighted Imaging–Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis vol.38, pp.2, 2013, https://doi.org/10.3174/ajnr.a4989
  5. Procedural Clinical Complications, Case-Fatality Risks, and Risk Factors in Endovascular and Neurosurgical Treatment of Unruptured Intracranial Aneurysms : A Systematic Review and Meta-analysis vol.76, pp.3, 2019, https://doi.org/10.1001/jamaneurol.2018.4165
  6. Silent brain infarction after minimally invasive cardiac surgery with retrograde perfusion vol.35, pp.8, 2020, https://doi.org/10.1111/jocs.14866