References
- 1992, Padberg, F.T.Jr., Lee, B.C. and Curl, G.R., "Hemoaccess site infection," Surg, Vol.174, pp.103-108.
- 2001, Gibson, K.D., Gillen, D.L. and Caps, M.T., "Vascular accesssurvival and incidence of revisions. A comparison of prosthetic grafts, simple autogenous fistulas, and venous trasposition fistulas, from the United States renal data system dialysis morbidity and mortality study," J. Vasc Surg, Vol.57, pp.639-645.
- 2000, Stehman-Breen, C.O., Sherrard, D.J. and Gillen, D., "Caps M: Determinants of type and timing of initial permanent hemodialysis vascular access," Kidney Int., Vol.57, pp.639-645. https://doi.org/10.1046/j.1523-1755.2000.00885.x
- 1999 Schwab, S.J., Harrington, J.T., Singh, A., Roher, R., Shohaib, S.A., Perrone, R.D., Meyer, K. and Beasley, D., "Vascular access for hemodialysis," Kidney Int., Vol.55, pp.2078-2090. https://doi.org/10.1046/j.1523-1755.1999.00409.x
- 2012, Kim, S.Y., Kim, H.Y. and Ryou, H.S., "Numerical analysis for the effect of dialysis dose on the non-newtonian blood flow characteristics in the arteriovenous graft," CMFF, pp.121-127.
- 2001, Roy-Chaudhury, P., Burnett, S.K., Mary, A.M., Anita, R., Janice, A., Nuwan, N. and Sue, C.H., "Venous neointimal hyperplasia in polytetra fluoroethylene dialysis graft," Kidney Int., Vol.59, pp.2325-2334. https://doi.org/10.1046/j.1523-1755.2001.00750.x
- 2005, Sunil, U., Thanh, N.H., Brott, B.C., Ito, Y., Cheng, C.H., Shih, A.M., Allon, M. and Andreas, S.A., "Turbulent flow evaluation of the venous needle during hemodialysis," J. Biomech Eng., Vol.127, No.7, pp.1141-1146. https://doi.org/10.1115/1.2112927
- 1994, Beathard, G.A., "The treatment of vascular access graft dysfunction: a nephrologist's view and experience," Adv Ren Replace Ther, Vol.1, No.2, pp.131-147. https://doi.org/10.1016/S1073-4449(12)80044-6
- 2005, Tricht, I.V., Wachter, D.D., Tordoir, J. and Verdonck, P., "hemodynamics and complications encountered with arteriovenous fistulas and graft as vascular access for hemodialysis: a review," ann. Biomed. End., Vol.33, No.9, pp.1142-1157. https://doi.org/10.1007/s10439-005-5367-X
- 1999, Redwood, A.J., Moore, S., Sayadelmi, L. and Tennant, M., "Autogenous artery grafts in hypertensive (SHR) rats do not have increased smooth muscle cell hyperplasia in the graft neointima, compared with grafts in normotensive rats, Journal of Anatomy," Vol.195, pp.407-412. https://doi.org/10.1046/j.1469-7580.1999.19530407.x
- 2006, Tricht, I.V., Wachter, D.D., Tordoir, J. and Verdonck, P., "Comparison of the hemodynamics in 6mm and 4-7mm hemodialysis graft by means of CFD," J. Biomech., Vol.39, No.2, pp.226-236. https://doi.org/10.1016/j.jbiomech.2004.12.003
- 2005, Tricht, I.V., Wachter, D.D., Tordoir, J. and Verdonck, P., "Experimental analysis of the hemodynamics in punctured vascular access graft," ASAIOJ, Vol.51, pp.352-359. https://doi.org/10.1097/01.mat.0000169126.91756.1d
- 2003, Haruguchi, H. and Teraoka, S., "Intimal Hyperplasia and Hemodynamic Factors in Arterial Bypass and Arteriovenous Grafts: A Review," J. Artif. Organs, Vol.6, pp.227-235. https://doi.org/10.1007/s10047-003-0232-x
- 1996, Kroll, M.H., Hellums, J.D., Mc Intire, L.V., Schafer, A.I. and Moake, J.L., "Platelets and shear stress Blood," Vol.88, pp.1525-1541.
- 1996, Salam, T.A., Lumsden, A.B., Suggs, W.D. and Ku, D.N., "Low shear stress promotes intimal hyperplasia thickening," Journal of Vascular Investment, Vol.2, pp.12-22.
- 2011, Kim, J.Y., Ro, K.C. and Ryou, H.S., "Numerical study on blood flow characteristics in a arteriovenous graft with delivered dose during hemodialysis," Journal of Computational Fluids Engineering, Vol.16, No.4, pp.84-91. https://doi.org/10.6112/kscfe.2011.16.4.084
- 2013, Ryou, H.S., Kim, S.Y. and Ro, K.C., "A numerical study of the effect of catheter angle on the blood flow characteristics in a graft during hemodialysis," korea-australia rheology journal, Vol.25, No.1, pp.19-27. https://doi.org/10.1007/s13367-013-0003-z
- 2010, Joseph, K., Ufuk, O., Stefan, C.S., Dimos, P., William, M.Jr., Pillippe, C.C., Hatem, A. and Vartan, K., "Choosing the optimal wall shear parameter for the prediction of plaque location a patient-specific computational study in human right coronary arteries," Atherosclerosis, Vol.211, No.2, pp.445-450. https://doi.org/10.1016/j.atherosclerosis.2010.03.001
- 2009, Bessa, K.L. and Ortiz, J.P., "Flow Visualization in Arteriovenous Fistula and Aneurysm using computational fluid dynamics," Journal of Visualization, Vol.12, pp.95-107. https://doi.org/10.1007/BF03181952
- 1999, Sharmila, S., How, T.V. and Bakran, A., "sites of stenosis in AV fistula for hemodialysis access," Nephrol Dial Transplant, Vol.14, pp.118-120. https://doi.org/10.1093/ndt/14.1.118
- 1999, Adel, M.M., Seth, L.A. and Seigo, I., "Hemodynamic Shear Stress and its Role in Atherosclerosis," JAMA, Vol.282, No.21, pp.2035-2042. https://doi.org/10.1001/jama.282.21.2035
- 2004, Zeller, J.A., Frahm, K., Baron, R., Stingele, R. and Deuschl, G., "Platelet leukocyte interaction and platelet activation in migraine: a link to ischemic stroke," J. Neurol Neurosurg Psychiatry, Vol.75, pp.984-987. https://doi.org/10.1136/jnnp.2003.019638
- 1996, He, X. and Ku, D.N., "pulsatile flow in the human left coronary artery bifurcation: average conditions," J. biomech. end., Vol.118, No.1, pp.74-82. https://doi.org/10.1115/1.2795948