Abstract

Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. 박원석 외, 신축공동공동주택의 기밀성능 실측에 관한연구, 한국생태환경건축학회 논문집, 2003
  2. 권오현 외, Blower Door를 이용한 국내주거용 건물의 기밀도 실측 사례 분석, 대한건축학회 논문집, 2010
  3. 문현준 외, 초고층 주거 건물에서의 차압 및 기밀성능 측정 연구, 한국건축친환경설비학회 추계학술발표대회 논문집, 2009
  4. 조재훈, 초고층 주거건물에서의 단위세대 기밀성능 측정 및 평가, 대한건축학회 논문집, 2010
  5. 윤종호 외, 충청지역 단독공동주택의 기밀성능 실측 연구, 한국태양에너지학회 논문집, 2008
  6. ASHRAE, 2009 ASHRAE Fundamentals Handbook

Cited by

  1. The Measurement of Airtightness Performance of Multi-Family Housing vol.14, pp.5, 2014, https://doi.org/10.12813/kieae.2014.14.5.117
  2. 창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 vol.40, pp.1, 2013, https://doi.org/10.7836/kses.2020.40.1.049
  3. The Analysis of Possibility for Zero Energy Building through Remodeling of Existing Detached Houses vol.20, pp.5, 2020, https://doi.org/10.12813/kieae.2020.20.5.165