초록

For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

키워드

참고문헌

  1. KSCIEC60079-10-1, Explosive Atmospheres - Part 10-1: Classification of areas - Explosive Gas Atmospheres, 2012.
  2. KSCIEC60079-14, Electrical Apparatus for Explosive Gas Atmospheres - Part 14: Electrical Installations in hazardous areas (other than mines), 2004.
  3. KSCIEC60079-17, Explosive Atmospheres Part 17:Electrical Installation Inspection and Maintenance, 2012.
  4. Sang-Won Choi, Gwan-Hyung Lee, Myung-Seob Kim and Eie-Soo Lim, "Development of a Light Weight Hand Lamp of Explosion-Proof Type", Fall Conference of the Korean Society of Safety, pp.135-142, 1997.
  5. IEC 60079-11 Part 11, Explosive Atmospheres-Equipment Protection by Intrinsic Safety "i", 2006.
  6. H. G. Bass, Intrinsic Safety Instrumentation for Flammable Atmospheres, Quartermaine House., U.K., 1984.
  7. Robin Garside, Intrinsically Safe Instrumentation: a Guide, Urwin Brothers Ltd., U.K., 1982.
  8. Sang-Won Choi, "An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material", Journal of the Korean Society of Safety, Vol. 27, No. 3, pp. 63-70. 2012.
  9. Sang-Won Choi, "An Experimental Study on Minimum Ignition Energy of Flammable Mixtures by Electric Power Frequency", Journal of the Korean Society of Safety, Vol. 27, No. 4, pp. 25-32. 2012.
  10. Sang-Won Choi, Seong-Choul Kim, "Explosion Protection Technique of Equipment and Transmission System Using Optical Radiation", Fall Conference of the Korean Society of Safety, p.8, 2010.
  11. IEC 60079-28(2006) / BS EN 60079-28(2007) : Explosive Atmospheres-Protection of Equipment and transmission Systems using Optical Radiation

피인용 문헌

  1. Survey and Analysis about the Safety Perception and Attitude of Managers in Construction Site vol.29, pp.4, 2014, https://doi.org/10.14346/JKOSOS.2014.29.4.097