초록
The purpose of this study were to develop and validate a prototype slipmeter used on-site floor. The developed slipmeter was dreg sled type. It measured static coefficient of friction(SCOF). The developed slipmeter was evaluated with ASTM 2508-11 which use four different standard surfaces(polished granite, glazed porcelain, vinyl composite tile, and ceramic tile). The SCOF was then measured with developed slipmeter under the three different contaminants and seven different floors. The test results of slipmeter were also compared with those of BOT-3000, floor surface roughness, and human perception. The test results revealed that developed slipmeter successfully ranked all four standard surfaces and differentiated among standard surfaces with varying degrees of slipperiness. The developed slipmeter couldn't properly measure slipperiness under the two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol). The test results of developed slipmeter had stronger correlation with those of BOT-3000 and floor roughness under the water and detergent solution than under the glycerol. The test results of developed slipmeter also showed stronger correlation with those of BOT-3000 and surface roughness than those of human perception. The newly developed slipmeter had been found to give consistent results under the test conditions except for two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol).