References
- Anton, S. and Kevin, F. (2005), Heat of hydration models for cementitious materials, Farmington Hills, MI, ETATS-UNIS, American Concrete Institute.
- Barr, P.J., Stanton, J.F. and Eberhard, M.O. (2005), "Effects of temperature variations on precast, prestressed concrete bridge girders", J. Bridge Eng., 10(2), 186-194. https://doi.org/10.1061/(ASCE)1084-0702(2005)10:2(186)
- Bhatia, V., Campbell, D., Claus,R.O. and Vengsarkar, A.M. (1997), "Simultaneous strain and temperature measurement with long-period gratings", Opt. Lett., 22(9), 648-650. https://doi.org/10.1364/OL.22.000648
- Cao, Y., Yim, J., Zhao, Y. and Wang, M.L. (2010), "Temperature effects on cable stayed bridge using health monitoring system: a case study", Struct. Health Monit., 10(5), 523-537.
- Culshaw, B., Michie, C., Gardiner, P. and McGown, A. (1996), "Smart structures and applications in civil engineering", Proceedings of the IEEE, 84(1), 78-86. https://doi.org/10.1109/5.476028
- da Silva, J.C.C., Martelli, C., Kalinowski, H.J., Penner, E., Canning, J. and Groothoff, N. (2007), "Dynamic analysis and temperature measurements of concrete cantilever beam using fibre Bragg gratings", Opt. Laser. Eng., 45(1), 88-92. https://doi.org/10.1016/j.optlaseng.2006.03.003
- Eliasson, I. (1992), "Infrared thermography and urban temperature patterns", Int. J. Remote Sens., 13(5), 869-879. https://doi.org/10.1080/01431169208904160
- Graham, P.C., Ballim, Y. and Kazirukanyo, J.B. (2011), "Effectiveness of the fineness of two South African Portland cements for controlling early-age temperature development in concrete", J. South African Inst.Civil Eng. 53, 39-45.
- Herbert, W. (2002), "Active IR-applications in civil engineering", Inf. Phys. Technol., 43(3-5), 233-238. https://doi.org/10.1016/S1350-4495(02)00145-7
- Inaudi, D. (2000), "Application of civil structural monitoring in Europe using fiber optic sensors", Prog. Struct. Eng. Mat. 2(3), 351-358. https://doi.org/10.1002/1528-2716(200007/09)2:3<351::AID-PSE41>3.0.CO;2-5
- Kesavan, K., Ravisankar, K., Parivallal, S, Sreeshylam, P. and Sridhar, S (2010), "Experimental studies on fiber optic sensors embedded in concrete", Measurement, 43(2), 157-163. https://doi.org/10.1016/j.measurement.2009.08.010
- Li, E. and Peng, G.D. (2008), "Wavelength-encoded fiber-optic temperature sensor with ultra-high sensitivity", Opt. Commun., 281(23), 5768-5770. https://doi.org/10.1016/j.optcom.2008.08.022
- Li, H. N., Li, D.S. and Song, G.B. (2004), "Recent applications of fiber optic sensors to health monitoring in civil engineering", Eng. Struct., 26(11), 1647-1657. https://doi.org/10.1016/j.engstruct.2004.05.018
- Ou, J. and Li, H. (2010), "Structural health monitoring in mainland China: review and future trends", Struct. Health Monit., 9(3), 219-231. https://doi.org/10.1177/1475921710365269
- PCA (1997), "Portland cement, concrete, and heat ofhydration", Concrete Technol. Today, 18(2).
- PCA (2009), Design and control of concrete mixtures, Skokie.
- Phan, L., Lawson, J. and Davis, F.L. (2001), "Effects of elevated temperature exposure on heating characteristics, spalling, and residual properties of high performance concrete", Mater. Struct., 34(2), 83-91. https://doi.org/10.1007/BF02481556
- Poole, J.L., Riding, K.A., Folliard, K.J., Juenger, M.C.G. and Schindler, A.K. (2007), "Methods for calculating activation energy for Portland cement", 104(1), 303-311.
- Quintela, A. (2002), "Embedded temperature-strain fibre Bragg grating sensor system validation for concrete structures", J. Opt. A - Pure App. Op., 4(6), S387. https://doi.org/10.1088/1464-4258/4/6/385
- Riding, K.A., Poole, J.L., Schindler, A.K., Juenger, M.C.G. and Folliard, K.J. (2006), "Evaluation of Temperature Prediction Methods for Mass Concrete Members", ACI Mater. J., 103(5), 357-365.
- Riding, K.A., Poole, J.L., Schindler, A.K., Juenger, M.C.G. and Folliard, K.J. (2007), "Temperature boundary condition models for concrete bridge members", ACI Mater. J., 104(4), 379-387.
- Roberts-Wollman, C.L., Breen, J.E. and Cawrse, J. (2002), "Measurements of thermal gradients and their effects on segmental concrete bridge", J. Bridge Eng., 7(3), 166-174. https://doi.org/10.1061/(ASCE)1084-0702(2002)7:3(166)
- Roque, R. and Buttlar, W.G. (1992), "The development of a measurement and analysis system to accurately determine asphalt concrete properties using the indirect tensile mode (with dicussion)", J. Assoc. Asphalt Paving Technol., 61, 304-322.
- Schindler, A.K. and McCullough, B.F. (2002), "Importance of concrete temperature control during concrete pavement construction in hot weather conditions", J. Transp. Res., 1813(1), 3-10.
- Soroka, I. and Ravina, D. (1998). "Hot weather concreting with admixtures", Cement Concrete Comp., 20(2-3), 129-136. https://doi.org/10.1016/S0958-9465(98)80005-X
- Sun, M., Li, Z., Liua, Q., Tang, Z. and Shen, D. (2000), "A study on thermal self-diagnostic and self-adaptive smart concrete structures", Cement Concrete Res., 30(8), 1251-1253. https://doi.org/10.1016/S0008-8846(00)00284-2
- Tian, Y., W. Wang, W., Wu, N., Zou, X., Guthy, C. and Wang, X. (2011), "A miniature fiber optic refractive index sensor built in a MEMS-based microchannel", Sensors, 11(1), 1078-1087. https://doi.org/10.3390/s110101078
- Wang, W., Wu, N., Tian, Y., Niezrecki, C. and Wang, X. (2010), "Miniature all-silica optical fiber pressure sensor with an ultrathin uniform diaphragm", Opt. Express, 18(9), 9006-9014. https://doi.org/10.1364/OE.18.009006
- Wu, N., Wang, W., Tian, Y., Zou, X., Maffeo, M., Niezrecki, C., Chen, J. and Wang, X. (2011), "Low-cost rapid miniature optical pressure sensors for blast wave measurements", Opt. Express, 19(11), 10797-10804. https://doi.org/10.1364/OE.19.010797
- Wu, N., Zou, X., Tian, Y., Fitek, J., Maffeo, M., Niezrecki, C., Chen, J. and Wang, X. (2012), "An ultra-fast fiber optic pressure sensor for blast event measurements", Meas. Sci. Technol., 23(5), 055102. https://doi.org/10.1088/0957-0233/23/5/055102
- Xiong, X. and Breugel, K.V. (2001), "Isothermal calorimetry study of blended cements and its application in numerical simulations", Heron, 46(3), 151-159.
- Xu, Q., Ruiz, J.M., Hu, J., Wang, K. and Rasmussen, R.O. (2011), "Modeling hydration properties and temperature developments of early-age concrete pavement using calorimetry tests", Thermochim. Acta, 512(1-2), 76-85. https://doi.org/10.1016/j.tca.2010.09.003
- Yuan, Y. and Wan, Z.L. (2002), "Prediction of cracking within early-age concrete due to thermal, drying and creep behavior", Cement Concrete Res., 32(7), 1053-1059. https://doi.org/10.1016/S0008-8846(02)00743-3
- Zou, X., Chao, A., Tian, Y., Wu, N., Zhang, H., Yu, T.Y. and Wang, X. (2012), "An experimental study on the concrete hydration process using Fabry-Perot fiber optic temperature sensors", Measurement, 45(5), 1077-1082. https://doi.org/10.1016/j.measurement.2012.01.034
- Zou, X., Chao, A., Wu, N., Tian, Y., Yu, T.Y. and Wang, X. (2012), "Miniature fiber optic temperature sensor for concrete structural health monitoring", Proceedings of the SPIE, 8345, 83454V.
Cited by
- Influence of curing temperatures on the hydration of calcium aluminate cement/Portland cement/calcium sulfate blends vol.80, 2017, https://doi.org/10.1016/j.cemconcomp.2017.03.016
- Nondestructive corrosion detection using fiber optic photoacoustic ultrasound generator vol.62, 2015, https://doi.org/10.1016/j.measurement.2014.11.004
- Design calibration and characterization of a robust low-cost fiber-optic 2D deflection sensor vol.267, 2017, https://doi.org/10.1016/j.sna.2017.10.014
- Prediction model for the hydration properties of concrete vol.12, pp.4, 2013, https://doi.org/10.12989/cac.2013.12.4.377
- Strain monitoring of reinforced concrete with OTDR-based FBG interrogation technique vol.20, pp.3, 2013, https://doi.org/10.12989/sss.2017.20.3.343
- Surface Rust Detection Using Ultrasonic Waves in a Cylindrical Geometry by Finite Element Simulation vol.3, pp.3, 2013, https://doi.org/10.3390/infrastructures3030029
- A review on structural health monitoring of railroad track structures using fiber optic sensors vol.33, pp.p7, 2020, https://doi.org/10.1016/j.matpr.2020.06.217
- Adding Effects of CaF2 and TiO2 as Mineralizers on the Sintering Temperature and Hardening Properties of Calcium Sulfoaluminate Cement vol.19, pp.12, 2013, https://doi.org/10.3151/jact.19.1309
- An embeddable spherical smart aggregate for monitoring concrete hydration in very early age based on electromechanical impedance method vol.32, pp.5, 2013, https://doi.org/10.1177/1045389x20963175