DOI QR코드

DOI QR Code

A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities

조직모델에서 냉.온치료기의 열전달 특성 비교 연구

  • Kim, Yu Jong (Department of Acupuncture & Moxibustion Medicine, College of Korean Medicine, Dongguk University) ;
  • Shin, Kyung Min (Acupuncture, Moxibustion & Meridian Research Group, Division of Medical Research, Korea Institute of Oriental Medicine) ;
  • Kim, Eun Jung (Department of Acupuncture & Moxibustion Medicine, College of Korean Medicine, Dongguk University) ;
  • Kim, Kyung Ho (Department of Acupuncture & Moxibustion Medicine, College of Korean Medicine, Dongguk University) ;
  • Kim, Kap Sung (Department of Acupuncture & Moxibustion Medicine, College of Korean Medicine, Dongguk University) ;
  • Lee, Seung Deok (Department of Acupuncture & Moxibustion Medicine, College of Korean Medicine, Dongguk University)
  • 김유종 (동국대학교 한의과대학 침구의학교실) ;
  • 신경민 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 김은정 (동국대학교 한의과대학 침구의학교실) ;
  • 김경호 (동국대학교 한의과대학 침구의학교실) ;
  • 김갑성 (동국대학교 한의과대학 침구의학교실) ;
  • 이승덕 (동국대학교 한의과대학 침구의학교실)
  • Received : 2013.08.14
  • Accepted : 2013.08.28
  • Published : 2013.09.20

Abstract

Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.

Keywords

References

  1. Tepperman PS, Devlin M. The therapeutic use of local heat and cold. Can Fam Physician. 1986 ; 32 : 1110-4.
  2. Nadler SF, Weingand K, Kruse RJ. The physiologic basis and clinical applications of cryotherapy and thermotherapy for the pain practitioner. Pain Physician. 2004 ; 7(3) : 395-9.
  3. Oh Chung-hee. Rehabilitation Medicine. 3rd edition. Seoul : Daehakseorim. 2011 : 79-89.
  4. Oosterveld FG, Rasker JJ. Effects of local heat and cold treatment on surface and articular temperature of arthritic knees. Arthritis Rheum. 1994 ; 37(11) : 1578-82. https://doi.org/10.1002/art.1780371104
  5. Trowbridge CA, Draper DO, Feland JB, Jutte LS, Eggett DL. Paraspinal musculature and skin temperature changes: comparing the Thermacare HeatWrap, the Johnson & Johnson Back Plaster, and the ABC Warme-Pflaster. J Orthop Sports Phys Ther. 2004 ; 34(9) : 549-58. https://doi.org/10.2519/jospt.2004.34.9.549
  6. Hong Yong-jae, Kim Cheul, Park Moon-soo, Kim Young-jun. Changes of pre-auricular cutaneous blood flow and skin temperature after dry heat therapy and moist heat therapy. Journal of Korean Academy of Oral Medicine. 2006 ; 31(1) : 47-57. Korean.
  7. Shin Misook, Shin Byungcheul, Lee Myeongjong et al. The utilization of physical therapies in the Korean medicine clinics: A survey for National Health Insurance planning. J Oriental Rehab Med. 2009 ; 19(3) : 101-9.
  8. Lindsay D, Dearness J, Richardson C, Chapman A, Cuskelly G. A survey of electromodality usage in private physiotherapy practices. Australian Physiotherapy. 1990 ; 36(4) : 249-56. https://doi.org/10.1016/S0004-9514(14)60527-4
  9. Allen RJ. Physical agents used in the management of chronic pain by physical therapists. Phys Med Rehabil Clin N Am. 2006 ; 17(2) : 315-45. https://doi.org/10.1016/j.pmr.2005.12.007
  10. Draper DO, Harris ST, Schulthies S, Durrant E, Knight KL, Ricard M. Hot-Pack and 1-MHz Ultrasound Treatments Have an Additive Effect on Muscle Temperature Increase. J Athl Train. 1998 ; 33(1) : 21-4.
  11. Shin Kyung-min. A comparative study on thermal characteristics between laser and indirect moxibustion in tissue models [dissertation]. Seoul : Dongguk Univ. 2012. .
  12. Kim Keun-jo, Lee Cu-ri. A Study about change in the temperature by each region and time after hot & cold application. The journal of Korean academy of physical therapist. 1995 ; 2(3) : 577-86.
  13. Akgun K, Korpinar MA, Kalkan MT, Akarirmak U, Tuzun S, Tuzun F. Temperature changes in superficial and deep tissue layers with respect to time of cold gel pack application in dogs. Yonsei Med J. 2004 ; 45(4) : 711-8. https://doi.org/10.3349/ymj.2004.45.4.711
  14. Lim Se-young, Yoo Sang-min, Bae Kyeong-yeon, Lee Yong-hyun, Jung Jae-joong. Research on the Effect and Satisfaction between Independenced and Parallelism Treatment of Acupuncture and Physical of Lumbago Patients. The Journal of Korean Acupuncture & Moxibustion Society. 2005 ; 22(6) : 75-84.
  15. Park Kyu-hyun, Kim Jae-yoon, Park Rae-Joon. Biophysical Principles of Superficial Heating and Deep Heating Agents. The journal of Korean Society of Physical Therapy. 2002 ; 14(1) : 197-203.
  16. Jang Jun-Hyuk, Kim Kyung-ho, Kim Jang-hyun. Effect of the Ceragem Master Heat Bed for Posterior Neck Pain and Low Back Pain. The journal of Korean oriental pediatrics. 2000 ; 14(2) : 133-40.
  17. Cho Kang-hee. Physical Therapy and Pharmacological Treatment of Lumbar Disc Herniations. Journal of the Korean Medical Association. 2004 ; 47(9) : 827-43. https://doi.org/10.5124/jkma.2004.47.9.827
  18. The Korean Academy of Oriental Rehabilitation Medicine. Oriental Rehabilitation Medicine. 2nd edition. Seoul : Koonja Press. 2007 : 317-8.
  19. Lienhard JH, Lienhard JH. A Heat Transfer Textbook. 3rd ed. Cambridge, MA, USA : Phlogiston Press. 2008 : 10-34.
  20. Kamen G. Foundations of Exercise Science. Philadelphia : Lippincott Williams & Wilkins. 2001 : 139.
  21. Knight KL, Draper DO. Therapeutic Modalities: The Art and Science. 2nd edition. Philadelphia : Lippincott Williams & Wilkins. 2012 : 185.
  22. Kim Yoon-hong, Lee Seung-ho, Yeo Su-jung, Choe Il-hwan, Kim Young-kon, Lim Sabina. The Study on Temperature Measurement for the Standardization of Moxibustion. The Journal of Korean Acupuncture & Moxibustion Society. 2008 ; 25(2) : 129-38.
  23. Wang Kai-hsia, Kim Eun-jung, Cho Hyun-seok, Kim Kap-sung, Lee Seung-deok, Kim Kyung-ho. A Comparative Study on Buffer Characteristic of Indirect Moxibustion. The Journal of Korean Acupuncture & Moxibustion Medicine Society. 2012 ; 29(5) : 75-85.
  24. Lee Geon-hui, Lee Geon-mok, Guk Uo-suk. Experimental Study on the Characteristics of Combustion in Indirect Moxibustion with Cake Insulation. The Journal of Korean Acupuncture & Moxibustion Society. 2004 ; 21(6) : 233-48.
  25. Kim YH, Baek SS, Choi KS, Lee SG, Park SB. The effect of cold air application on intra-articular and skin temperatures in the knee. Yonsei Med J. 2002 ; 43(5) : 621-6. https://doi.org/10.3349/ymj.2002.43.5.621
  26. The Korean Academy of Oriental Rehabilitation Medicine. Oriental Rehabilitation Medicine. 2nd edition. Seoul : Koonja Press. 2007 : 333.
  27. Hayes BT, Merrick MA, Sandrey MA, Cordova ML. Three-MHz Ultrasound Heats Deeper Into the Tissues Than Originally Theorized. J Athl Train. 2004 ; 39(3) : 230-4.
  28. Aubry JF, Pernot M, Marquet F, Tanter M, Fink M. Transcostal high-intensity-focused ultrasound: ex vivo adaptive focusing feasibility study. Phys Med Biol. 2008 ; 53(11) : 2937-51. https://doi.org/10.1088/0031-9155/53/11/012
  29. Merrick MA, Mihalyov MR, Roethemeier JL, Cordova ML, Ingersoll CD. A Comparison of Intramuscular Temperatures During Ultrasound Treatments With Coupling Gel or Gel Pads. J Orthop Sports Phys Ther. 2002 ; 32(5) : 216-20. https://doi.org/10.2519/jospt.2002.32.5.216
  30. Kim Oh-young, Seo Ki-taek, Choi Chang-young et al. Development of Jelly-type Simulating Human Tissue for Research on Hyperthermia by High Frequency Magnetic Field. Applied Chemistry. 2006 ; 10(2) : 393-6.
  31. Cho Ji-yong, Kim Jung-kyung. Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 ㎚ Infrared Laser. Journal of the Korean Society of Visualization. 2010 ; 8(4) : 54-9. https://doi.org/10.5407/JKSV.2010.8.4.054
  32. Habash RW, Bansal R, Krewski D, Alhafid HT. Thermal therapy, part 1: an introduction to thermal therapy. Crit Rev Biomed Eng. 2006 ; 34(6) : 459-89. https://doi.org/10.1615/CritRevBiomedEng.v34.i6.20