초록

Generally, the chassis of an indoor RAC is composed of a rear-guider and a stabilizer. The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of the chassis of an indoor RAC. The purpose of this paper is to select the optimum design factors through the aerodynamic performance of a cross-flow fan. The design factors are the leading angle of a rear-guider (${\theta}_1$), a stabilizer setup angle(${\theta}_2$), a rear-guider clearance(${\epsilon}_1$), and a stabilizer clearance(${\epsilon}_2$), respectively. As a result, the optimum design factors of an indoor RAC can be presented as a combination of ${\theta}_1=33^{\circ}$, ${\theta}_2=55^{\circ}$, ${\epsilon}_1=6{\sim}8mm$, and ${\epsilon}_2=7mm$ through the analysis of a static pressure coefficient and a static pressure efficiency.

키워드

참고문헌

  1. P. Mortier, 1893, "Fan or Blowing Apparatus", U. S. Patent No. 507445.
  2. A. M. Porter and E. Markland, 1970, "A Study of the Cross Flow Fan", J. Mechanical Engineering Science, Vol. 12, No. 6, pp. 421-431. https://doi.org/10.1243/JMES_JOUR_1970_012_071_02
  3. H. Ilberg and W. Z. Sadeh, 1965, "Flow Theory and Performance of Tangential Fans", Proc. Instn. Mech. Engrs., Vol. 180, Part 1, No. 19, pp. 481-491. https://doi.org/10.1243/PIME_PROC_1965_180_034_02
  4. S. Murata and K. Nishihara, 1976, "An Experimental Study of Cross Flow Fan (1st Report, Effects of Housing Geometry on the Fan Performance)", Bulletin of the JSME, Vol. 19, No. 129, pp. 314-321. https://doi.org/10.1299/jsme1958.19.314
  5. L. Preszler and T. Lajos, 1972, "Experiments for the Development of the Tangential Flow Fan", Proc. of the 4th Conference on Fluid Machinery, Budapest, Akademiai Kiado, pp. 1071-1082
  6. H. Tsurusaki et al., 1993, "Study of Cross-Flow Fan Internal Flow by Flow Visualization (1st Report, Discussion of Measured Results by Particle-Tracking Velocimetry)", Trans. of JSME (Series B), Vol. 59, No. 568, pp. 3743-3748. https://doi.org/10.1299/kikaib.59.3743
  7. A. Toffolo, A. Lazzaretto and A. D. Martegani, 2004, "An Experimental Investigation of the Flow Field Pattern within the Impeller of a Cross-Flow Fan", Experimental Thermal and Fluid Science, Vol. 29, No. 1, pp. 53-64. https://doi.org/10.1016/j.expthermflusci.2004.02.007
  8. S. H. Seo, N. Y. Lee, J. H. Lee, S. W. Chin and K. S. Im, "A Study of Stabilizer for the Noise Reduction in Room Air Conditioner", Proc. of KSNVE 1995 Fall Annual Meeting, pp. 136-141.
  9. H. M. Koo, 1999, "An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner", Trans. of KSME (Part B), Vol. 23, No. 6, pp. 695-702.
  10. J. K. Kim, 1996, "Judging Method of Rear-Guider Shape of Cross-Flow Fan", K. S. Patent No. 107610, November 13. (In Korean)
  11. J. K. Kim and K. J. Jeong, 2005, "Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner", J. of KSPSE, Vol. 9, No. 3, pp. 33-38.
  12. T. Ikui and M. Inoue, 1988, "Turbo-Blowers and Compressors", Corona Publishing Co., LTD., pp. 293-297.