Supported by : 식품의약품안전청
Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were applied to identify the cookie molds mixed with 2 mg of 10 kGy-irradiated minerals according to cookie processing methods and sonication time (0~60 min) for mineral separation. PSL analysis showed that photon counts of cookies, dried or baked, ranged intermediate levels between the lower and upper threshold (700~5,000 counts/60 s), thereby showing its unsuitablility for screening of irradiated cookie. The TL glow curve intensities, measured according to mineral separation time (5, 10, 20, 40 and 60 mins) from the cookies using a sonicator, were high enough to identify irradiation status and significantly increased with the time in dried cookies. Those of baked cookies, however, were relatively low and not linearly increased with the time, but still possible to identify them (p<0.05).
Supported by : 식품의약품안전청