References
- Aaserud, O., Juntunen, J. and Matikainen, E., Vibration sensitivity thresholds: Methodological considerations, Acta Neurologica Scandinavica, 82(4), 277-283, 1990.
- Bae. T.S., Kim. H.J., Kim. S.B., Jang. Y.H., Kim. S.K. and Mun. M.S., Effect of Multi-Channel Vibration Stimulation on Somatosensory Sensibility, Journal of the Korean Society for Precision Engineering, 28(6), 651-656, 2011.
- Blaak and Ellen., Gender differences in fat metabolism, Current Opinion in Clinical Nutrition & Metabolic Care, 4(6), 499-502, 2001. https://doi.org/10.1097/00075197-200111000-00006
- Chatterjee, A., Chaubey, P., Martin, J. and Thakor, N., Testing a prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task, Journal of Prosthetics and Orthotic, 20(2), 27-34, 2008. https://doi.org/10.1097/01.JPO.0000311041.61628.be
- Era, P., Jokela, J., Suominen, H. and Heikkinen, E., Correlates of vibrotactile thresholds in men of different ages, Acta Neurologica Scandinavica, 74(3), 210-217,1986. https://doi.org/10.1111/j.1600-0404.1986.tb07857.x
- Fucci, D., Turman, A., Shaw. J., Walsh, N. and Aguyen, V., Lingual vibrotatile threshold shift differences between stutterers and normal speakers during magnitude-estimation scaling, Perceptual and Motor Skills, 73(1), 55-62, 1991. https://doi.org/10.2466/pms.1991.73.1.55
- Goldberg, J.M. and Lindblom, U., Standardised method of determining vibratory perception thresholds for diagnosis and screening in neurological investigation, Journal of Neurology Neurosurgery and Psychiatry, 42(9), 793-803, 1979. https://doi.org/10.1136/jnnp.42.9.793
- Hunter, J.P., Dissociation of phantom limb phenomena from stump tactile spatial acuity and sensory thresholds, Brain, 128(2), 308-320, 2004. https://doi.org/10.1093/brain/awh350
- Judith B. Kosasith, B.S.-T., Sensory Changes in Adults with Unilateral Transtibial Amputation, Jounanl of Rehabilitation Research and Development, 35(1), 85-90, 1998.
- Kaczmarek, K.A., Webster, J.G., Bach-y-Rita, P. and Tompkins, W.J., Electrotactile and vibrotactile displays for sensory substitution system, IEEE Transactions on Biomedical Engineering, 38(1), 1-16, 1991. https://doi.org/10.1109/10.68204
- Kim, S.B., Chang, Y.H., Kim, S.K., Kim, G.S., Mun, M.S. and Bae, T.S., The Measurement of the Magnitude of Sensory Perception and Displeasure to the Vibration Stimuli applied on Forearm in upper Limb Amputees, Journal of the Korean Society for Precision Engineering, 29(7), 705-710, 2012. https://doi.org/10.7736/KSPE.2012.29.7.705
- Lee, Y. and Hwang, K., Skin Thickness of Korean Adults, Surgical and Radiologic Anatomy, 24(3), 183-189, 2002. https://doi.org/10.1007/s00276-002-0034-5
- Lundborg, G. and Rosen, B., Sensory substitution in prosthetics." Hand Clinics, 17(3), 481-488, 2001.
- Pylatiuk, C., Kargov, A. and Schulz, S., Design and evaluation of a lowcost force feedback system for myoelectric prosthetic hand, Journal of Prosthetics and Orthotic, 18(2), 57-61, 2006. https://doi.org/10.1097/00008526-200604000-00007
- Renold, A.E. and Cahill, G.F., Section 5, Adipose tissue, Hand book of Physiology, 64(2), 480, 1965.
- Ryu, J. and Kim, G.J., Using a Vibro-Tactile Display for Enhanced Collision Perception and Presence, The ACM international Coference on Virtual Reality Software and Technology (pp. 89-96), 2004.
- Savic, G., Bergstrm, E.M.K., Davey, N.J., Ellaway, P.H., Frankel, H.L., Jamous, A. and Nicotra, A., Quantitative sensory tests (perceptual thresholds) in patients with spinal cord injury, The Journal of Rehabilitation Research and Development, 44(1), 77, 2007. https://doi.org/10.1682/JRRD.2005.08.0137
- Scott, R.N., Feednack in myoelectric prosthese, Clinical Orthopaedics and Related Research, 256, 58-63, 1990.
- Shannon, G.F., A comparision of alternative means of providing sensory feedback on upper limb prostheses, Medical and Biological Engineering, 14(3), 289-294, 1974.
- Stuart, M., Turman, A.B., Shaw, J., Walsh, N. and Nguyen, V., Effects of aging on vibration detection thresholds at various body regions, BMC Geriatrics, 3, 1-10, 2003. https://doi.org/10.1186/1471-2318-3-1
- Sueda, O. and Tamura, H., Sensory device for the artificial arm, 8th International Conference on Medical and Biological Engineering, 1969.
- Yarnitsky, D., Quantitative sensory testing, Muscle and Nerve, 20(2), 198-204, 1997. https://doi.org/10.1002/(SICI)1097-4598(199702)20:2<198::AID-MUS10>3.0.CO;2-#