The original pilot-scale electrokinetic equipment suitable to soil contamination characteristics of Korean nuclear facility sites was manufactured for the remediation of soil contaminated with uranium. During the experiment with the original electrokinetic equipment, many metal oxides were generated and were stuck on the cathode plate. The uranium removal capability of the original electrokinrtic equipment was almost exhausted because the cathode plate covered with metal oxides did not conduct electricity in the original electrokinetic equipment. Therefore, the original electrokinetic equipment was improved. After the remediation experience for 25 days using the improved electrokinetic remediation equipment, the removal efficiency of uranium from the soil was 96.8% and its residual uranium concentration was 0.81 Bq/g. When the initial uranium concentration of soil was about 50 Bq/g, the electrokinetic remediation time required to remediate the uranium concentration below clearance concentration of 1.0 Bq/g was about 34 days. When the initial uranium concentration of soil was about 75 Bq/g, the electrokinetic remediation time required to remediate below 1.0 Bq/g was about 42 days. When the initial uranium concentration of soil was about 100 Bq/g, the electrokinetic remediation time required to remediate below 1.0 Bq/g was about 49 days.

방사능 오염 토양 복원을 위해 실험실 규모의 동전기 복원장치를 제작하여 가동 하던 중 토양 내 존재하던 금속이온의 용출로 금속 산화물이 발생하여 음극의 전류 흐름을 차단하는 문제가 발생하였다. 전류의 차단으로 토양 내 우라늄 제거 능력이 상실되어 이러한 문제를 해결하는 해결 방안을 모색하여 개선된 동전기 복원 장치를 제작하였다. 개선된 실험실 규모 동전기 복원 장치를 이용하여 토양복원 실험을 25 일간 수행 하였을 때 우라늄 잔류 농도는 0.81 Bq/g으로 약 96.8%의 제거 효율을 보였으며, 초기 우라늄 농도 50 Bq/g 일 때 우라늄 규제 해제 농도인 1 Bq/g 이하로 제거 되기 까지는 34 일의 복원 기간이 필요하고, 초기 우라늄 농도 75 Bq/g, 100 Bq/g 일 때 각 42 일, 49 일이 필요한 것으로 나타났다.

Keywords

References

  1. G.N. Kim, W.K. Choi, C.H. Bung and J.K. Moon, "Development of a washing system for soil contaminated with radionuclides around Triga reactors", J. Ind. Eng. Chem., 13, pp. 406-413 (2007)
  2. G.N. Kim, Y.H. Jung, J.J. Lee and J.K. Moon, " Development of electrokinetic flushing technology for remediation of the contaminated site around nuclear facilities", J. Korean Radioact. Waste Soc., 25(2), pp. 146-153 (2008).
  3. USEPA, In Situ Remediation Technology: Electrokinetics, EPA542-k-94-007, U.S. Environmental protection agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC (1995).
  4. G.Y. Lee, "A Study on the removal efficiency of arsenic in fine-soil after soil-washing by electrokinetic remediation", A master's thesis, The university of Seoul (2010).
  5. S. Pamukcu, A. Weeks and J. K. Wittle, "Electrochemical extraction and stabilization of selected inorganic species in porous media", J. Hazard. Mater., 55, pp. 305-318 (1997). https://doi.org/10.1016/S0304-3894(97)00025-3
  6. Y.B. Acar and A.N. Alshawabkeh, "Principles of electrokinetic remediation", Environ. Sci. Technol., 27(13), pp. 2638-2647 (1993). https://doi.org/10.1021/es00049a002
  7. G.N. Kim, B.I. Yang, J.K. Moon and K.W. Lee, "Vertical electrokinetic-flushing remediation", Sep. Sci. Technol., 44, pp. 2354-2370 (2009). https://doi.org/10.1080/01496390902983703
  8. G.N. Kim, B.I. Yang, W.K. Choi and K.W. Lee, "Development of certical electrokinetic-flushing decontamination technology to remove $^{60}Co\;and\;^{137}Cs$ from a Korean nuclear facility site"Sep. Purif. Technol., 68, pp. 222-226 (2009). https://doi.org/10.1016/j.seppur.2009.05.015
  9. L. van Cauwenberghe, Electrokinetics, GWRTAC Technology overview report, TO-97-03, Ground-Water Remediation Technologies Center, Pittsburg, PA, 1997.
  10. E.C. Buck, N.R. Brown and N.L. Dietz, "Contaminant uranium phases and leaching at the Fernald site in Ohio", Environ. Sci. Technol., 30, pp. 80-88 (1996).
  11. C.W. Francis, A.J. Mattus, M.P. Elless and M. E. Timpson, Carbonate-and citrate-based selective leaching of uranium from uranium-contaminated soils: Part 1. Removal of uranium from uranium-contaminated soils: Phase 1 bench scale testing, Oak Ridge National laboratory, U.S. Department of energy (1993).
  12. S. Pamukcu and J.K. Wittle, "Electrokinetic removal of selected heavy metals from soil", Environ. Prog., 11(3), pp. 241-250 (1992). https://doi.org/10.1002/ep.670110321
  13. K. Reddy, C.Y. Xu and S. Chinthamreddy, " Assessment of electrokinetic removal of heavy metals form soil by sequentical extraction analysis", J. Hazard. Mater., B84, pp. 279-296 (2001).
  14. K. Reddy and S. Chinthamreddy, "Sequentially enhanced electrokinetic remediation of heavy metals in low buffering clayey soils", J. Geotech. Geoenviron. Eng., March, pp. 263-277 (2003).
  15. F. Braud, S. Tellier and M. Astruc, "Modelling of decontamination rate in an electrokinetic soil processing", Int. J. Environ. Anal. Chem., 68, pp. 105-121 (1998).
  16. S.O. Kim, S.H. Moon and K.W. Kim, "Removal of heavy metals from soils using enhanced electrokinetic soil precessing", Water, Air, Soil Pollution, 125, pp. 259-272 (2001). https://doi.org/10.1023/A:1005283001877
  17. M.M. Page and C.L. Page, "Electroremediation of contaminated soils", J. Environ. Eng., ASCE 128, pp. 208-219 (2002). https://doi.org/10.1061/(ASCE)0733-9372(2002)128:3(208)
  18. M. Macka, P. Nesterenko and P.R. Haddad, "Investigation of solute-wall interaction in separation of uranium(VI) and lanthanides by capillary electro-phoresis using on-capillary complexation with arsenazo III", J. Microcolumn Sep., 11, pp. 1-9 (1999). https://doi.org/10.1002/(SICI)1520-667X(1999)11:1<1::AID-MCS1>3.0.CO;2-U
  19. S. Scapolan, E. Ansoborlo, C. Moulin and C. Madic, "Uranium speciation in biological medium by means of capillary electrophoresis and timeresolved laser induced fluorescence", J. Radioanal. Nucl. Chem., 226, pp. 145-148 (1997). https://doi.org/10.1007/BF02063639
  20. G.E. Collins and Q. Lu, "Microfabricated capillary electrophoresis sensor for uranium (VI)", Anal. Chim. Acta., 436, pp. 181-189 (2001). https://doi.org/10.1016/S0003-2670(01)00903-5
  21. A.P. Shapiro and R.F. Probstein, "Removal of contaminants from saturated clay by electro osmosis", Environ. Sci. Technol., 27, pp. 283-291 (1993). https://doi.org/10.1021/es00039a007
  22. R. Lageman, W. Pool and G. Seffinga, "Electro-reclamatiom: theory andpractice", Chem. Ind., 8, pp. 585-590 (1989).

Cited by

  1. Improved Treatment Technique for the Reuse of Waste Solution Generated from a Electrokinetic Decontamination System vol.12, pp.1, 2014, https://doi.org/10.7733/jnfcwt.2014.12.1.1