DOI QR코드

DOI QR Code

파장이 다른 레이저의 임플란트 세정 효과에 관한 연구

Study on Implant Cleaning Effect of Lasers of Different Wavelengths

  • Park, Eun Kyeong (Department of Advanced parts and Materials Engineering, Chosun Univ.) ;
  • Yang, Yun Seok (Department of Advanced parts and Materials Engineering, Chosun Univ.) ;
  • Lee, Ka Ram (Department of Advanced parts and Materials Engineering, Chosun Univ.) ;
  • Yoo, Young Tae (Department of Mechatronics Engineering, Chosun Univ.)
  • 투고 : 2013.06.19
  • 심사 : 2013.07.26
  • 발행 : 2013.08.15

초록

This study applied a laser cleaning method (dry cleaning) that is used for cleaning semiconductor elements to dental implant cleaning. The lasers used in this study were pulsed fiber lasers with wavelengths of 1,064 and 532 nm. The peak output, energy per pulse, energy density per pulse, time of pulse experiment, and number of pulse experiments served as process variables for this study, and the variables were changed for each experiment. As a result, a laser with a wavelength of 532 nm showed much higher cleaning efficiency than its 1,064 nm counterpart. As the wavelength range decreased, the quantized energy increased and the reflection rate of the titanium used for the implant decreased; consequently, the energy absorption rate increased. Therefore, it is proposed that the energy density by wavelength has a greater influence on cleaning than does the output size.

키워드

참고문헌

  1. Lee, W. J., Kim D. J., Han, J. S., 2004, Hydroxyapatite Coating Technology of Dental Implant, Korean Journal of Ceramics, 7:1 21-29.
  2. Krozer, A., Hall, J., Ericsson, I., 1999, Chemical Treatment of Machined Titanium Surfaces. An in Vitro Study, Clinical Oral Implants Research, 10:3 204-211. https://doi.org/10.1034/j.1600-0501.1999.100303.x
  3. Kim, J. H., 2009, The Effect of Er:YAG Laser Irradiation on the Surface Microstructure and Roughness of Fluoride-Modified TiO2 Implant, A Thesis for a Master, Kyunghee University, Republic of Korea.
  4. Meffert, R. M., Langer, B., Fritz, M. E., 1992, Dental Implant: A Review, Journal of Periodontology, 63:11 859-870. https://doi.org/10.1902/jop.1992.63.11.859
  5. Zablotsky, M. H., Diedrich, D. L., Meffert, R. M., 1992, Detoxification of Endotoxin-contaminated Titanium & Hydroxyapatite- coated Surfaces Utilizing Various Chemotherapeutic & Mechanical Modalities, Implant Dentistry, 1:2 154-158. https://doi.org/10.1097/00008505-199205000-00009
  6. Roos-Jansaker, A. M., Renvert, S., Egelberg. J., 2003, Treatment of Peri-Implant Infections: A Literature Review, J. of Clinical Periodontology, 30:6 467-485. https://doi.org/10.1034/j.1600-051X.2003.00296.x
  7. Bae, H. S., 2011, The Effects of Implant Cleaning to the Implant Surface Characteristics, A Thesis for a Doctorate, Kyungpook National University, Republic of Korea.
  8. National Center for Remanufacturing & Resource Recovery (NC3R), 2000, viewed 21 March 2013, Ultrasonic Cleaning of Automotive Parts .
  9. Shin, C. H., Lin, J., 2006, Removal Mechanisms of Micro Scale Particles by Surface Wave in Laser Cleaning, Optics and Laser Technology, 38:7 544-551. https://doi.org/10.1016/j.optlastec.2004.11.021
  10. Lee, J. M., 2002, Laser and Cleaning Processing, Hanrimwon Publisher, Republic of Korea.
  11. Mittal, K. L., 1988, Particles on Surfaces, Plenum Press, Netherlands.
  12. Cappella, B., Dietler, B., 1999, Force-distance Curves by Atomic Force Microscopy, Elsevier Publisher, Netherlands.
  13. Lee, J. M., Curran, C., Watkins, K. G., 2001, Laser Removal of Copper Particles form Silicon Wafer using UV, Visible and IR Radiation, Applied Physics A, 73:2 219-224. https://doi.org/10.1007/s003390100685
  14. Shin, H. J., Yang, Y. S., Hwang, C. Y., Yoo, Y. T., 2011, A Study on the Surface Treatment of Dental Implant using a Fiber Laser, Journal of the Korean Society for Precision Engineering, 28:8 915-928.
  15. Kim, D. H., 2005, Laser Manufacturing Processes, Kyungmoon Publisher, Republic of Korea.
  16. Turner, M. W., Crouse, P. L., Li, L., 2007, Comparative Interaction Mechanisms for Different Laser Systems with Selected Materials on Titanium Alloys, Applied Surface, 253:19 7992- 7997. https://doi.org/10.1016/j.apsusc.2007.02.173