경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과

Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture

  • 정형진 (인제대학교 의과대학 상계백병원 정형외과) ;
  • 추지웅 (인제대학교 의과대학 상계백병원 정형외과)
  • Chung, Hyung-Jin (Department of Orthopedic Surgery, Sanggye Paik Hospital, Inje University Collage of Medicine) ;
  • Choo, Ji Woong (Department of Orthopedic Surgery, Sanggye Paik Hospital, Inje University Collage of Medicine)
  • 투고 : 2013.04.13
  • 심사 : 2013.05.21
  • 발행 : 2013.06.15

초록

Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.

키워드

참고문헌

  1. Collinge C, Protzman R. Outcomes of minimally invasive plate osteosynthesis for metaphyseal distal tibia fractures. J Orthop Trauma,. 2010;24:24-9. https://doi.org/10.1097/BOT.0b013e3181ac3426
  2. Park Sk, Oh CW, Oh JK, et al. Staged minimally invaasice plate osteosynthesis of distal tibial fractures. J Koreanh FRactu5e Soc. 2010;23:289-95. https://doi.org/10.12671/jkfs.2010.23.3.289
  3. Maffulli N, Toms AD, McMurtie A, Oliva F. Percutaneous plating of distal tibial fractures. Int Orthop. 2004;28:159-62. https://doi.org/10.1007/s00264-004-0541-6
  4. Chung ST, Kim HS, Cha SD, et al. Treatment of distal tibia fracture using MIPO technique with locking compression plate: comparative study of the intraarticular fracture and extraarticular fracture. J Korean Foot Ankle Soc. 2009;13: 162-8.
  5. Lau TW, Leung F, Chan CF, Chow Sp. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008;32:697-703. https://doi.org/10.1007/s00264-007-0384-z
  6. Pai V, Coulter G, Pai V. Minimally invasive plate fixation of the tibia. Int Orthop. 2007;31:491-6. https://doi.org/10.1007/s00264-006-0228-2
  7. Gardner TN, Hardy J, Evans M, Kenwright J. Temporal changes in dynamic interfragmentary motion and callusformation in fractures, J biomech. 1997;30:315-21. https://doi.org/10.1016/S0021-9290(96)00156-X
  8. Shon OJ, Kim DS. Minimally invasive percutaneous plate osteosynthesis using a lateral plate in distal tibial fracture. J Korean Fracture Soc. 2010;23:42-9. https://doi.org/10.12671/jkfs.2010.23.1.42
  9. Hasenboehlar E, Rikli D, Babst R. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Injury. 2007;38:365-70. https://doi.org/10.1016/j.injury.2006.10.024
  10. Lee KB. Distal tibia fracture: plate osteosynthesis. J Korean Fracture Soc. 2009;22:406-13.
  11. Baumgaertel F, Buhl M, Rahn BA. Fracture healing in biological plate osteosynthesis. Injury. 1998;29;3Suppl 3:C3-6. https://doi.org/10.1016/S0020-1383(98)95002-1
  12. Krackhardt T, Dilger J, Flesch I, Hontsch D, Eingartner C, Weise K. Fractures of the distal bivia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg. 2005;125:87-94. https://doi.org/10.1007/s00402-004-0778-y
  13. Park KC, Park YS. Minimally invasive plate osteosynthesis for distal tibial metaphyseal fracture. J Korean Fracture Soc. 2005;18:264-8. https://doi.org/10.12671/jkfs.2005.18.3.264
  14. Collinge C, Protzman R. Outcomes of minimally invasive plate osteosynthesis for metaphyseal distal tibia fractures. J Orthop Trauma,. 2010;24L;24-9.
  15. Hente R, Fuchtmeier , Schlegel U, et al. The influence of cyclic compression and distraction on the healing of experimental tibial fracture, J orthop Res. 2004;22(4);709-15. https://doi.org/10.1016/j.orthres.2003.11.007
  16. Kenwright J, Goodship AE. Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop Relat Res. 1989;241:36-47.
  17. Kenwight J. Richardson JB, Cunningham JL, et al. Axial movement and tibial fractures. A controlled randomised trial of treatment J bone Joint Surg Br. 1991;74(4);654-9.
  18. Aro HT, Choa EY. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop Relat Res. 1993; 293:8-17.
  19. C. Horn, S. Dobele, H. Vester, A. Schaffler, M Lucke, u. Stockle. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: J. Care injured. 2011;42;1031-37. https://doi.org/10.1016/j.injury.2011.05.010
  20. Wawro W, Otto W. Operative Behandlung der distalen unterschenkelfrakturunter besonderer Berucksichtigung der winkelstabilen Olattenosteosynthese. Trauma und Berufskrankheit. 2003;5;134-40.
  21. Yamaji T, Ando K, Wolf S, et al. The effect of micromovement on callus formation. J Orthop Sci. 2001;6(6);571-5. https://doi.org/10.1007/s007760100014
  22. Helfet DL, Suk M. Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia. instrCoruse Lect. 2004;53:471-5.
  23. Lee HS, KimJJ, OH SK, Ahn HS. Treatment of distal tibial metaphyseal fracture using MIPPO technique. J Korean Foot Ankle Soc. 2004;8:166-70.
  24. Maffulli N, Toms AD, McMurtie A, Oliva F. Percutaneous plating of distal tibial fractures. Int Orthop,. 2004; 28:159-62. https://doi.org/10.1007/s00264-004-0541-6
  25. Ghera S, Santeri FS, Calderaro M, Giorgini TL. minimally invasive plateosteosynthesis in distal tibial fractures: pitfalls and surgical guidelines. Orthopedics. 2004;27:903-5.
  26. Kim YM, Shin HD, Yang JY, Yang JH, Lee HJ, Kim KC. Percutaneous temporal wiring method for minimally invasive plate osteosynthesis of a distal tibial fracture. Orthopedics. 2009;32:177. https://doi.org/10.3928/01477447-20090301-17
  27. Hasenboehler E, Rikli D, Babst R. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Janury. 2007;38:365-70.
  28. Borrelli J Jr, Prickett W, Song E, Becker D, Ricci W. Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma. 2002; 16:691-5. https://doi.org/10.1097/00005131-200211000-00002
  29. Young Mo Kim, Chan kang, Deuk-Soo Hwang. Anatomically Percutaneous Wiring Reduction in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fractures . J Korean Fracture Soc. 2011; vol. 24; 230-6. https://doi.org/10.12671/jkfs.2011.24.3.230