DOI QR코드

DOI QR Code

Investigation of Winding Connections for Fault-Tolerant of MW Class Offshore Wind Generator with Dual 3-Phase System and Modular

이중 3상 시스템과 모듈러를 갖는 MW급 해상용 풍력발전기의 무정지 기능을 위한 권선 체결방식에 관한 연구

  • Seo, Jang Ho (School of Automotive Engineering, Kyungpook National University)
  • Received : 2013.02.27
  • Accepted : 2013.06.12
  • Published : 2013.08.01

Abstract

This paper presents a new winding topology for MW class offshore wind generator having modular and dual 3-phase. Based on proposed simplified relationship between magnetic flux and phase current in the air gap, several new windings for modular and dual 3-phase are made. In case of one inverter operation or faulty operation, the proposed model can have balanced 3-phase induced voltage whereas the conventional generator with modular winding has unbalanced induced voltage, which can be important issue in offshore generator. The model was applied into 6MW prototype machine with dual 3-phase. Using finite element analysis, induced voltage, inductance were investigated. The results show that the proposed modular winding can be applicable to dual inverter system with electrically balanced voltage.

Keywords

References

  1. Emil Levi, "Multiphase electric machines for variable-speed applications," IEEE Trans. Industrial Electronics, vol. 55, No, 5, pp. 1893-1909, 2008. https://doi.org/10.1109/TIE.2008.918488
  2. M. Barcaro, N. Bianchi, and F. Magnussen, "Configurations of fractional-slot IPM Motors with dual three-phase winding," in IEEE International Electric Machines and Drives Conference, pp. 936-942, 2009.
  3. M. Barcaro, N. Bianchi, and F. Magnussen, "Analysis and tests of a dual three-phase 12-slot 10-pole permanent magnet motor," in IEEE Energy Conversion Congress and Exposition, pp. 3587-3594, 2009.
  4. C. Jie, W. Jiabin, K. Atallah, and D. Howe, "Performance Comparison and Winding Fault Detection of Duplex 2-Phase and 3-Phase Fault-Tolerant Permanent Magnet Brushless Machines," in IEEE Industry Applications Conference, pp. 566-572, 2007.
  5. N. Bianchi and M. Dai Pre "Use of the star of slots in designing fractional-slot single-layer synchronous motors," IEE Proc. -Electr. Power Appl., vol. 153, No. 3, pp. 459-466, 2006. https://doi.org/10.1049/ip-epa:20050284
  6. N. Bianchi, S. Bolognani, M. Dai Pre, and G. Grezzani "Design considerations for fractional-slot winding configurations of synchronous machines," IEEE Trans. Industry Appl., vol. 42, No. 4, pp. 997-1006, 2006. https://doi.org/10.1109/TIA.2006.876070
  7. N. Bianchi, S. Bolognani, and E. Fornasiero, "An overview of rotor losses determination in three-phase fractional-sloot PM machines," IEEE Trans. Industry Applications, vol. 46, No. 6, Nov. 2010.
  8. K. Atallah, D. Howe, P. H. Mellor, and D. A. Stone, "Rotor loss in permanent-magnet brushless AC machines," IEEE Trans. Industry Applications, vol. 36., No. 6, Nov. 2000.
  9. Alberti Luigi and Bianchi Nicola, "Impact of winding arrangement in dual 3-phase induction motor for fault tolerant applications," in IEEE International Conference on Electrical Machines, 2010.
  10. Alberti Luigi and Bianchi Nicola, "Experimental Tests of Dual Three-Phase Induction Motor Under Faulty Operating Condition," IEEE Trans. Industrial electronics, vol. 59, No. 5, May 2012.