DOI QR코드

DOI QR Code

혈압파형에 초점을 맞춘 심혈관계 시뮬레이터의 개발

Development of a Cardiovascular Simulator Focused on the Pressure Wave

  • 이주연 (상지대학교 일반대학원 동서의료공학과) ;
  • 장민 (상지대학교 일반대학원 한방의료공학과) ;
  • 신상훈 (상지대학교 보건과학대학 한방의료공학과)
  • Lee, Ju-Yeon (Depart. of East-West Medical Engineering, Sangji University) ;
  • Jang, Min (Depart. of Oriental Biomedical Engineering, Sangji University) ;
  • Shin, Sang-Hoon (Depart. of Oriental Biomedical Engineering, Sangji University)
  • 투고 : 2013.01.31
  • 심사 : 2013.03.21
  • 발행 : 2013.02.28

초록

The conventional simulators used the expensive commercial artificial heart with a limited performance, and focused on replicating the heart function. The arterial pressure is the key factor of the cardiovascular disease. The purpose of this study is to develop a simulator focused on the pressure wave. The simulator is composed of a step motor, slider-crank mechanism, piston-cylinder, two check valves, a elastic tube, and two reservoirs. With the changes of design parameters, the functions of the simulator were evaluated. The simulator shows the good agreement of the characteristics of the cardiovascular system.

키워드

참고문헌

  1. National Statistical Office, "Cause of death statistics 2011" .
  2. D. Timms, M. Hayne, K. McNeil, and A. Galbraith, "A complete mock circulation loop for the evaluation of left-rightand biventricular assist devices," Artif Organs, vol. 29, no. 7, pp. 564-571, 2005. https://doi.org/10.1111/j.1525-1594.2005.29094.x
  3. G.M. Pantalos, S.C. Koenig, K.J. Gillars, G.A. Giridharan, and D.L. Ewert, "Characterization of an adult mock circulation for testing cardiac support devices," ASAIO J, vol. 50, no. 1, pp. 37-46, 2004. https://doi.org/10.1097/01.MAT.0000104818.70726.E6
  4. T.I. Marx, B.R. Baldwin, and C.F. Kittle, "A cardiovascular simulator for the evaluation of prosthetic aortic valves," J Thorac Cardiovasc Surg, vol. 38, pp. 412-418, 1959.
  5. K.H. Kim, C.M. Hwang, G.S. Jeong, C.B. Ahn, B.S. Kim et al., "Assessment of Hemodynamic Properties of Trileaflet Polymer Heart Valve Manufactured By Vacuum Forming Process," J. Biomed. Eng. Res., vol. 27, no. 6, pp. 418-426, 2006.
  6. J. Bruma, D. Biab, N. Benecha, G. Balaya, R. Armentanob et al., "Set up of a cardiovascular simulator: application to the evaluation of the dynamical behavior of atheroma plaques in human arteries," Physics Procedia, vol. 3, pp. 1095-1101, 2010. https://doi.org/10.1016/j.phpro.2010.01.142
  7. H. Schima, H. Baumgartner, F. Spitaler, P. Kuhn and E. Wolner E, "A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices," Int J Artif Organs, vol. 15, no. 7, pp. 417-421, 1992.
  8. GM. Pantalos, C. Ionan, SC. Koenig, KJ. Gillars, T. Horrell et al., "Expanded pediatric cardiovascular simulator for research and training," ASAIO J, vol. 56, no. 1, pp. 67-72, 2010. https://doi.org/10.1097/MAT.0b013e3181c838ae
  9. P. Segers and P. Verdonck, "Role of tapering in aortic wave reflection: hydraulic and mathematical model study," Journal of Biomechanics, vol. 33, no. 3 pp. 299-306, 2002.
  10. R.J. Rodeheffer, G. Gerstenblith, L.C. Becker, J.L. Fleg, M.L. Weisfeldt et al., "Exercise cardiac output is maintained with advancing age in healthy human subjects: cardiac dilatation and increased stroke volume compensate for a diminished heart rate," Circulation, vol. 69, no. 2, pp. 203-213, 1984. https://doi.org/10.1161/01.CIR.69.2.203
  11. S.H. Shin and Y.B. Park, "Effects of changes in the physical properties of the central elastic artery on haemodynamic characteristics during ageing," JEIM, vol. 223, pp. 525-535, 2009.
  12. A.P. Avolio. "Multi-branched model of the human arterial system," Medical and Biological Engineering and Computing, vol. 18, no. 6, pp. 709-718, 1980. https://doi.org/10.1007/BF02441895
  13. D.J. Patel, J.S. Janicki, and T.E. Carew, "Static anisotropic elastic properties of the aorta in living dogs," Circulation Research, vol. 25, pp. 765-779. 1969. https://doi.org/10.1161/01.RES.25.6.765
  14. A.C. Pearson, R. Guo, D.A. Orsinelli, PF. Binkley and TJ. Pasierski, "Transesophageal echocardiographic assessment of the effects of age, gender, and hypertension on thoracic aortic wall size, thickness, and stiffness," American Heart Journal, vol. 128, pp. 344-351, 1994. https://doi.org/10.1016/0002-8703(94)90488-X
  15. D. Legendre, J. Fonseca, A. Andrade, J.F. Biscegli, R. Manrique et al., "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases," Artif Organs, vol. 32, no. 6, pp. 461-467, 2008. https://doi.org/10.1111/j.1525-1594.2008.00569.x
  16. J.Y. Lee and S.H. Shin, "Development of the Cardiovascular Simulator for Pulse Diagnosis Study," The Journal Of The Korea Institute Of Oriental Medical Diagnostics, vol. 16, no. 1, pp. 19-26, 2012.
  17. Y. Nagai, J. Metter, C.J. Earley, M.K. Kemper, L.C. Becker et al., "Increased carotid artery intimal-medial thickness in asymptomatic older subjects with exercise-induced myocardial ischemia," Circulation, vol. 98, pp. 1504-1509, 1998. https://doi.org/10.1161/01.CIR.98.15.1504
  18. S.S. Franklin, W.IV. Gustin, N.D. Wong, M.G. Larson, M.A. Weber et al, "Hemodynamic Patterns of Age-Related Changes in Blood Pressure, The Framingham Heart Study," Circulation, vol. 96, pp. 308-315, 1997. https://doi.org/10.1161/01.CIR.96.1.308

피인용 문헌

  1. Development of Cardiovascular Simulator with Control of Pulse Pressure for Pulse Wave Study vol.51, pp.10, 2014, https://doi.org/10.5573/ieie.2014.51.10.204