Purpose: In order to find out the impact of changes in polymerization conditions of orthodontic acrylic resin on maximum load. Methods: While maintaining mixing ratio 3:1 of polymer and monomer in spray-on way in the production condition of polymerization temperature $25^{\circ}C$ or $37^{\circ}C$ for 10 minutes or 30 minutes of polymerization time by pressure $3kfg/cm^2$ or $6kfg/cm^2$ in the lab maintaining $25^{\circ}C$ of room temperature, the change in maximum load rise rate was tested by producing 5 acrylic resin specimens for orthodontics per group to meet the standards of $25mm{\times}2mm{\times}2mm$ and using INSTRON with the 3rd bar 2mm in diameter and parallel support bending device of $15{\pm}0.1mm$ as test equipment showing 30.00mm/min of crosshead speed, $50{\pm}16$ N/min of load ratio in the laboratory of $24^{\circ}C$ room temperature and as a result, the following results were obtained. Results: 1. When increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, maximum load was lowered by -4.285%. 2. When increasing polymerization time from 10 minutes to 30 minutes, maximum load rose by 3.848%. 3. When increasing polymerization temperature from $27^{\circ}C$ to $37^{\circ}C$, maximum load rose by 5.854%. Conclusion: Considering the above test results that polymerization time and polymerization temperature when polymerizing acrylic resin for orthodontics according to changes in working conditions had an impact on the rate of rise of maximum load values but the rate of rise was lowered when increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, we came to a conclusion that high pressure more than necessary does not affect the rate of rise of maximum load.

키워드

참고문헌

  1. Kim KN, Kim KH, Kim HI, Park YJ, Bae TS, Lim HN, Cho HW. Dental Materials. 1st Edition, Koonja Publishing, Inc, 159-90, 1995.
  2. Yoo JW, Jang KT, Kim CC. A study on the degree of polymerization of autopolymerized resin for removable orthodontic appliance according to curing time and and curing method. J Korean Acad Pediatr Dent, 26(2), 304, 1999.
  3. Austin AT, Easker RK. Residual monomer levels in denture bases. Br Dent J., 153, 424, 1982. https://doi.org/10.1038/sj.bdj.4804962
  4. Beech DR. Molecular weight distribution of denture base acrylics. J. Prosthet Dent. 3, 19-22, 1975.
  5. Dogan A, Bek B, Cevik NN, Usanmaz A. The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption. J Dent, 23, 313-8, 1995. https://doi.org/10.1016/0300-5712(94)00002-W
  6. Donovan TE, Hurst RG, Campagni WV. Physical properties of acrylic resin polymerized by four different techniques. J Prosthet Dent, 54, 522-4, 1985. https://doi.org/10.1016/0022-3913(85)90425-1
  7. Ferraane JL, Moser JB, Greener EH. Color stability of unfilled Bis-GMA resins under UV exposure. AADR Progr & Abst, 62, 453, 1983.
  8. Fletcher AM. Purnaveja S. Amin WM et al. The level of residual monomer in self curing denture base materials. Dent Res, 62(2), 118-120, 1983. https://doi.org/10.1177/00220345830620020601
  9. Furnish GM, O'Toole TJ, von Fraunhofer JA. The polymerization of acrylic resin orthodontic prostheses. J Prosthet Dent, 49, 276-8, 1983. https://doi.org/10.1016/0022-3913(83)90515-2
  10. Kalipcilar B. Karragaclioglu L. Hasanreisoglu U. Evaluation of the level of residual monomer in acrylic denture base materials having different polymerization properties. Journal of oral rehabilitation, 18, 399-401, 1991.
  11. Ogawa T, Tanaka M, Koyano K. Effect of water temperature during polymerization on strength of autopolymerizing resin. J Prosthet Dent, 84, 222-4, 2000. https://doi.org/10.1067/mpr.2000.108574
  12. Peutzfeldt A. Resin composites in dentistry: The monomer system. Eur J Oral Sci 105, 97-116, 1997. https://doi.org/10.1111/j.1600-0722.1997.tb00188.x
  13. Phillips M: Elements of dental materials. 5th ed, 100-116, 1994.
  14. Undurwade, JH. Sidhaye, AB. Curing acrylic resin in a domestic pressure cooker: A study of residual monomer content. Quintessence International, 20(2), 1989.
  15. Vallittu PK, Ruyter IE, Buykuilmaz S. Effect of polymerization temperature and time on the residual monomer content of denture base polymers. Eur J Oral Sci, 106, 588-93, 1998. https://doi.org/10.1046/j.0909-8836.1998.eos106109.x
  16. Vallittu PK. Unpolymerized surface layer of autopolymerizing polymethyl methacrylate resin. Oral Rehabil, 26, 208-212, 1999. https://doi.org/10.1046/j.1365-2842.1999.00360.x
  17. Weaver RE, Goebel WM. Reactions to acryli resin dental prostheses. J Prosthet Dent 43, 138-142, 1980. https://doi.org/10.1016/0022-3913(80)90176-6
  18. Wu W. Degree of cure and wear resistance of dental composites. J Dent Res, 62, 671, 1983.