DOI QR코드

DOI QR Code

A Study on Performance Test and Fabrication of Vacuum Glazing with Numerical Analysis

수치해석을 통한 진공유리 제작 및 성능실험에 관한 연구

  • Hwang, Il Sun (Department of Mechanical Engineering, Graduate School, Kongju National University) ;
  • Lee, Young Lim (Department of Mechanical and Automative Engineering, Kongju National University)
  • 황일선 (공주대학교 대학원 기계공학과) ;
  • 이영림 (공주대학교 기계자동차공학부)
  • Received : 2013.01.25
  • Published : 2013.06.10

Abstract

For air-tight modern buildings, secondary damage is likely to occur due to condensation in the relatively high heat-transmission windows since water vapor is not easy to discharge. Therefore, in this study, condensation performance of vacuum glazing was numerically analysed, compared with that of ordinary glass and confirmed experimentally by three sheets of vacuum glazing manufactured. The results show that the heat transmission coefficient of the vacuum glazing whose internal pressure is $10^{-3}$ torr was as low as about $5.7W/m^2{\cdot}K$. Thus, the condensation performance as well as the adiabatic performance was greatly improved compared to that of the ordinary glass.

Keywords

References

  1. Dewar, J. and Dewar, L., 1927, Collected papers of sir james dewar, Cambridge University Press, Cambridge.
  2. Zoller, A., 1913, Hohle glasscheibe, deutsches reich patenschrift : No. 387655.
  3. Bachli, E., 1987, Heat-insulating construction and/or lighting element, International Patent Application No : PCT/CH 86/00166.
  4. Robinson, S. J. and Collins, R. E., 1986, Evacuated windows-theory and practice, ISES solar world congress, International Solar Energy Society, Kobe, Japan.
  5. Lee, B. H., Yoon, I, S., Song, T. H., and Kwak, H. S., 2006, Experimental study on manufacturing of insulation vacuum glazing and measurement of the thermal conductance, Journal of KSME, Vol. 30, No. 251, pp. 715-828.
  6. Fang, Y., Hyde, T. J., and Hewitt, N., 2010, Predicted thermal performance of triple vacuum glazing, Solar Energy, Vol. 84, No. 12, pp. 2132-2139. https://doi.org/10.1016/j.solener.2010.09.002
  7. Kim, J. M., Lee, J. H., and Song, T. H., 2012, Vacuum insulation properties of phenolic foam, International Journal of Heat and Mass Transfer, Vol. 55, No. 19-20, pp. 5343-5349. https://doi.org/10.1016/j.ijheatmasstransfer.2012.05.051
  8. Bernardi, A., Becherini, F., Bassato, G., and Bellio, M., 2006, Condensation on ancient stained glass windows and efficiency of protective glazing systems : two French case studies, Sainte-Chapelle(Paris) and Saint-Urbain Basilica(Troyes), Journal of Cultural Heritage, Vol. 7, No. 1, pp. 71-78. https://doi.org/10.1016/j.culher.2005.10.007
  9. Werner, A. and Roos, A., 2007, Condensation tests on glass samples for energy efficient windows, Solar Energy Materials and Solar Cells, Vol. 91, No. 7, pp. 609-615. https://doi.org/10.1016/j.solmat.2006.11.015
  10. EES, 2012, F-chart Software LLC., V9.100-3D.
  11. Ansys CFX version 14, 2012, Ansys inc., User's Manual version 14.
  12. Determining the steady state thermal transmittance of fenestration systems, ASTM Standard.
  13. Lee, J. W. and Lim, J. M., 2004, The experimental study on a effect of Korean Paper(Hanji) on indoor humidity control, Korean J. Air-Conditioning and Ref. Eng, Vol. 16, No. 6, pp. 599-607.