DOI QR코드

DOI QR Code

The Design and Implementation of Arc Power supply for Neutral Beam Injection

중성입자빔 가열을 위한 아크 전원 공급장치 설계 및 구현

  • 이희준 (성균관대학교 전자전기컴퓨터공학과) ;
  • 신수철 (성균관대학교 대학원 전자전기컴퓨터공학과) ;
  • 이승교 (성균관대학교 대학원 정보통신공학부, 다원시스) ;
  • 정용채 (남서울대학교 전자공학과) ;
  • 원충연 (성균관대학교 전자전기컴퓨터공학과)
  • Received : 2013.02.21
  • Accepted : 2013.04.23
  • Published : 2013.06.30

Abstract

The Neutral Beam Injection(NBI) generates ultra-high temperature energy in the tokamak of nuclear fusion. The NBI consists of filament power supply acceleration and deceleration power supply and arc power supply(APS). The APS has characteristics of low voltage and high current. APS generate arc through constant output of voltage and current. So this paper proposed suitable buck converter for low voltage and high current. The case of proposed buck converter used parallel switch because it can increase capacity and decrease conduction loss. When an arc is generated, the NBI chamber occur high voltage. And it will break output capacitor of buck converter. Therefore the output capacitor was removed in the proposed converter. Thus buck converter with constant output is the most important design of the output inductor. In this paper, designed APS verified operation of system and stability through simulation and prototype.

Keywords

References

  1. 3 korea atomic energy research institute, "korea superconducting tokamak advanced research project", Ministry of science and technology 2007.
  2. Bea young sun, "Plasma heating and current drive technology", March. 2008.
  3. kim woong chae, "Status of KSTAR operating with the prospect of fusion power generation", journal of the electrical world No 383, pp 27-30, 11 2008.
  4. B. S. Jun, S. H. Lee, H. J. Lee, S. C. Shin, S. K. Lee, C. Y. Won, "Full-Bridge DC/DC Converter for NBI filament power supply", Journal of KIIEE, vol.25, NO. 7, pp32-39, July 2011. https://doi.org/10.5207/JIEIE.2011.25.7.032
  5. D. H. Chang, B. H. Oh, "Development and testing of a prototype Long Pulse Ion Source for the KSTAR Neutral Beam System", Journal of the korean nuclear society, vol 36. Num 4, pp 357-363, Aug 2004.
  6. D. H. Chang, S. H. Jeong, B. H. Oh, K. W. Lee, C. S. Seo, "Arc discharge efficiency of a multi megawatt long pulse ion source for the KSTAR neutral beam injector", Plasma sources Sci. Technol, 14 pp 36-341, 2005. https://doi.org/10.1088/0963-0252/14/1/005
  7. Y. S. Bae, "Tokamak plasma heating and electric current driving gear" The Korea Institute of Applied Superconductivity and Cryogenics, volume 11 unit1, pp. 38 - 44 , 2009.
  8. M. Bigi, L.Zanotto "Circuit Analyses of the Filament Ion Source Power Supplies for the ITER Neutral Beam Test Facility" 2005.
  9. Zhihua Yang, Sheng Ye, Yan-Fei Liu, "A New Resonant Gate Drive Circuit for Synchronous Buck Converter", IEEE Trans, Vol. 22, No. 4, pp. 1311-1320, 2007.
  10. Jiann-Fch Chen, Jiinn-Nan Lin, Tsu-Hsu-Hua-Hua Ai, "The techniques of the serial and paralleled IGBTs", IECON, vol. 2. pp. 999-1004, Aug 1996.
  11. Jiann-Fch Chen, Jiinn-Nan Lin, Tsu-Hsu-Hua-Hua Ai, "The techniques of the serial and paralleled IGBTs", IECON, vol. 2. pp. 999-1004, Aug 1996.
  12. Soo-Seok Kim, "The Analysis of Parallel Operating Characteristics for DC-DC Converter Using the Parallel Operation Model", Journal of the korean institute of llluminating and Electrical installation Engineers, Vol, 18. No 5,pp. 174-182, September 2004. https://doi.org/10.5207/JIEIE.2004.18.5.174