DOI QR코드

DOI QR Code

Parameter Design and Power Flow Control of Energy Recovery Power Accumulator Battery Pack Testing System

  • Bo, Long (School of Mechanical, Electronic, and Industrial Engineering, University of Electronic Science and Technology of China) ;
  • Chong, Kil To (Advanced Electronics and Information Research Center, Departments of Electronics & Information Engineering, Chonbuk National University)
  • Received : 2012.06.30
  • Accepted : 2013.03.12
  • Published : 2013.07.01

Abstract

This paper proposes a special power circuit topology and its corresponding control strategy for an energy recovery power accumulator battery pack testing system (PABPTS), which is particularly used in electric vehicles. Firstly, operation principle and related parameter design for the system are illustrated. Secondly, control strategy of the composite power converter for PABPTS is analyzed in detail. The improved scheme includes a high accuracy charge and discharge current closed loop. active power reference for the grid-side inverter is provided by the result of multiplication between battery pack terminal voltage and test current. Simulation and experimental results demonstrate that the proposed scheme could not only satisfy the requirements for PABPTS with wide-range current test, but also could recover the discharging energy to the power grid with high efficiency.

Keywords

References

  1. L. Zhang, W. Kang, L. Jia, M. Zhao, and R. Xu, "Control of Bidirectional Current Source SVPWM Converter in the Power Accumulator Battery Testing System," in Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific, 2010, pp. 1-4.
  2. N. J. Fellner C, "High.power batteries for use in hybrid vehules," Power Sources, vol. 85(1):229-236., 2000. https://doi.org/10.1016/S0378-7753(99)00344-4
  3. Y. Xiangwu, D. Chunlin, L. Heming, Z. Lixia, and W. Fang, "Application of three-phase current source converter in power battery testing system for electric vehicles," in Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on, 2008, pp. 4205-4209.
  4. G.-c. Li and H.-y. Wang, "Study on Fuzzy Control in Power Battery Testing System," in Control and Automation, 2007. ICCA 2007. IEEE International Conference on, 2007, pp. 1110-1112.
  5. J. Gill, "Advanced EV/HEV battery pack testing using the ABC-150 power system," in Battery Conference on Applications and Advances, 1997., Twelfth Annual, 1997, pp. 127-131.
  6. H. Kobayashi, M. Shikano, S. Koike, H. Sakaebe, and K. Tatsunii, "Investigation of positive electrodes after cycle testing of high-power Li-ion battery cells I. An approach to the power fading mechanism using XANES," Journal of Power Sources, vol. 174, pp. 380-386, Dec 6 2007. https://doi.org/10.1016/j.jpowsour.2007.06.134
  7. B. Schweighofer, K. M. Raab, and G. Brasseur, "Modeling of high power automotive batteries by the use of an automated test system," Instrumentation and Measurement, IEEE Transactions on, vol. 52, pp. 1087-1091, 2003. https://doi.org/10.1109/TIM.2003.814827
  8. M. Uno and K. Tanaka, "Accelerated Charge- Discharge Cycling Test and Cycle Life Prediction Model for Supercapacitors in Alternative Battery Applications," Industrial Electronics, IEEE Transactions on, vol. 59, pp. 4704-4712, 2012. https://doi.org/10.1109/TIE.2011.2182018
  9. B. Long, Z. Xian, S. T. Lim, and K. T. Chong, "Design of Energy Recovery Power Battery Pack Testing System," International Review of Electrical Engineering-Iree, vol. 7, pp. 4672-4683, Jul-Aug 2012.
  10. L. Fei, Z. Yan, D. Shanxu, Y. Jinjun, L. Bangyin, and L. Fangrui, "Parameter Design of a Two-Current- Loop Controller Used in a Grid-Connected Inverter System With LCL Filter," Industrial Electronics, IEEE Transactions on, vol. 56, pp. 4483-4491, 2009. https://doi.org/10.1109/TIE.2009.2021175
  11. H. Mahmood and J. Jin, "Modeling and Control System Design of a Grid Connected VSC Considering the Effect of the Interface Transformer Type," Smart Grid, IEEE Transactions on, vol. 3, pp. 122-134, 2012. https://doi.org/10.1109/TSG.2011.2166412
  12. X.-Q. Guo, W.-Y. Wu, and H.-R. Gu, "Modeling and simulation of direct output current control for LCLinterfaced grid-connected inverters with parallel passive damping," Simulation Modelling Practice and Theory, vol. 18, pp. 946-956, 2010. https://doi.org/10.1016/j.simpat.2010.02.010
  13. G. Tsengenes, T. Nathenas, and G. Adamidis, "A three-level space vector modulated grid connected inverter with control scheme based on instantaneous power theory," Simulation Modelling Practice and Theory, vol. 25, pp. 134-147, 2012. https://doi.org/10.1016/j.simpat.2012.02.004
  14. J. H. Lee, H. G. Jeong, and K. B. Lee, "Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller," Journal of Electrical Engineering & Technology, vol. 7, pp. 918-925, Nov 2012. https://doi.org/10.5370/JEET.2012.7.6.918
  15. J. H. Lee, D. Y. Jung, T. K. Lee, Y. R. Kim, and C. Y. Won, "Regenerative Current Control Method of Bidirectional DC/DC Converter for EV/HEV Application," Journal of Electrical Engineering & Technology, vol. 8, pp. 97-105, Jan 2013. https://doi.org/10.5370/JEET.2013.8.1.097
  16. M. A. Abusara and S. M. Sharkh, "Design and Control of a Grid-Connected Interleaved Inverter," Power Electronics, IEEE Transactions on, vol. 28, pp. 748-764, 2013. https://doi.org/10.1109/TPEL.2012.2201505
  17. J. Muhlethaler, M. Schweizer, R. Blattmann, J. W. Kolar, and A. Ecklebe, "Optimal Design of LCL Harmonic Filters for Three-Phase PFC Rectifiers," Power Electronics, IEEE Transactions on, vol. 28, pp. 3114-3125, 2013. https://doi.org/10.1109/TPEL.2012.2225641

Cited by

  1. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System vol.8, pp.12, 2015, https://doi.org/10.3390/en8021181
  2. Energy Management of a Grid-connected High Power Energy Recovery Battery Testing System vol.11, pp.4, 2016, https://doi.org/10.5370/JEET.2016.11.4.839