Abstract
During the magnetic abrasive polishing of a curved surface, the improvement in surface roughness varies with the maximum value and distribution of magnetic flux density. Thus, in this study, the magnetic flux density on the curved surface was simulated according to curvature radii of magnetic tool. As a result of the simulation, the 14.5mm of the magnetic tool had a higher maximum magnetic flux density and it showed a large weighted magnetic flux density. The weighted magnetic flux density means the highest value for the magnetic flux density in the curvature of the magnetic tool. From the experimental verification, the better improvement in surface roughness was observed on wider area at the 14.5mm radius of the magnetic tool than other radii.