참고문헌
- Benjamin WJ. Clinical Refraction, 1st Ed. Philadelphia: W.B. Saunders Company, 1998;Chap11.
- Goo GU, Ryu SH, Lee SE. Optical characteristic of flexible back-light unit with plasma discharge clusters. Trans Electri Electron Mater. 2011;12(5):189-192. https://doi.org/10.4313/TEEM.2011.12.5.189
- Cho BG. Study on lighted frame using LED backlight system operated by sensing of light. J Korean Soc Imaging Sic & Tech. 2011;17(3):1-6.
- Kim, YC, Kang HS, Cho E, Kim DY, Chung DS, Kim IH, et al. Building a backlight unit with lateral gate structure based on carbon nanotube field emitters. Nanotechnology. 2009;20(9):594-605
- Kim HJ, Kim DW, Kim SW. Improvement of optical and thermo-mechanical propeties of polycarbonate-based diffusers for LED backlight unit by incorporation of porous silica particles. Polymer. 2012;36(6):761-767.
- Lee SJ, Lee JC. Design and evaluation of LCD backlight unit by LED array modules. Trans Electrical and Electronics Materials. 2008;9(3):110-115. https://doi.org/10.4313/TEEM.2008.9.3.110
- Elecom. Blue light cut glasses for protecting your eyes in a stylish design, made with clear lenses for natural visibility, 2013. http://www.elecom.co.jp/global/release/201301/ og-ablc05/index.html(22 January 2013).
- Park SI. The effect of brown tinted or UV-A blocking ophthalmic lens against the photooxidation of A2E a lipofuscin in retina. J Korean Oph Opt Soc. 2012;17(1):91-97.
- Lee CW, Jeong KI, Hwang KH, Lee SJ, Yoo GC. A study of Sterilization effect of long-wavelength UVA-LED irradiation on bacteria causing eye diseases. J Korean Oph Opt Soc. 2012;17(1):99-105.
- Park, MJ, Kim SH, Ku BK, Kim SR. Comparisons of the change in soft contact lenses parameters and the cleaning efficiency after eyeliner deposition. J Korean Oph Opt Soc. 2013;18(2):107-115. https://doi.org/10.14479/jkoos.2013.18.2.107
- Kim SR, Choi JH, Lee KG, Park MJ. Changes in the covering of pupil and the visual acuity by the illuminance when wearing circle soft contact lens. J Korean Oph Opt Soc. 2013;18(1):19-25. https://doi.org/10.14479/jkoos.2013.18.1.019
- Choi EJ, Lee SU, Lee EJ, Yoon MJ, Jeong JH, Kim CJ, et al. Emprical fitting curve for luminous transmittance in tinted lenses using superposition of exponential decay curves. J Korean Oph Opt Soc. 2011;16(3):283-291.
- Lee SH, Lee YJ, Cho HG. Changes of contrast sensitivity according to light transmittance of color lenses. Korea Academia-Industral Cooper Soc. 2009;10(11):3427-3433. https://doi.org/10.5762/KAIS.2009.10.11.3427
- Song YY, Lee HJ. Studies in changes in color sensation of traffic lights when wearing sunglasses. Korean J Vis Sci. 2003;5(2):45-61.
- Park SA, Kim YG. The confusing color line of the color deficiency in panel D-15 using CIELab color space. J Korean Oph Opt Soc. 2001;6(1):139-144.
피인용 문헌
- Evaluation of Blue-light Blocking Ratio and Luminous Transmittance of Blue-light Blocking Lens based on International Standard vol.19, pp.2, 2014, https://doi.org/10.14479/jkoos.2014.19.2.135
- Evaluation of Blue Light Hazards in LED Lightings vol.20, pp.3, 2015, https://doi.org/10.14479/jkoos.2015.20.3.293
- The Effect of Blue-light Blocking Ophthalmic Lenses on Legibility and Fatigue during Near work with a Smartpad vol.22, pp.1, 2017, https://doi.org/10.14479/jkoos.2017.22.1.81
- 청색광 차단렌즈에서 미광이 상의 질에 미치는 영향 vol.17, pp.5, 2013, https://doi.org/10.5762/kais.2016.17.5.612
- Analysis of Optical Performance in Blue Light Blocking Lenses vol.19, pp.4, 2013, https://doi.org/10.17337/jmbi.2017.19.4.375
- The Effect of Blue-Light Blocking Lens on Legibility and Subjective Symptoms during Near Work with Different Background Colors Using a Smart Device vol.24, pp.1, 2013, https://doi.org/10.14479/jkoos.2019.24.1.51
- Analysis on the Light Transmittance of Blue-Light Blocking Lenses by Manufacturing Methods vol.22, pp.2, 2013, https://doi.org/10.17337/jmbi.2020.22.2.113
- 다양한 색상의 착색렌즈와 치과용 팁의 청광차단율 비교의 융합적 연구 vol.12, pp.7, 2021, https://doi.org/10.15207/jkcs.2021.12.7.061
- 광중합기용 팁과 시판용 청광 차단 렌즈 및 노란색 착색 렌즈의 청광 투과율 비교 융합 연구 vol.12, pp.7, 2013, https://doi.org/10.15207/jkcs.2021.12.7.125