DOI QR코드

DOI QR Code

The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room

  • Ryu, Jae Sung (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center) ;
  • Baek, Seung Woo (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center) ;
  • Jung, Cheol Hee (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center) ;
  • Cho, Suk Ju (Jeju National University Hospital) ;
  • Jung, Eu Gene (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center) ;
  • Kim, Hae Kyoung (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center) ;
  • Kim, Jae Hun (Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center)
  • Received : 2012.11.19
  • Accepted : 2013.01.09
  • Published : 2013.04.01

Abstract

Background: Medical doctors who perform C-arm fluoroscopy-guided procedures are exposed to X-ray radiation. Therefore, radiation-protective shields are recommended to protect these doctors from radiation. For the past several years, these protective shields have sometimes been used without regular inspection. The aim of this study was to investigate the degree of damage to radiation-protective shields in the operating room. Methods: This study investigated 98 radiation-protective shields in the operation rooms of Konkuk University Medical Center and Jeju National University Hospital. We examined whether these shields were damaged or not with the unaided eye and by fluoroscopy. Results: There were seventy-one aprons and twenty-seven thyroid protectors in the two university hospitals. Fourteen aprons (19.7%) were damaged, whereas no thyroid protectors (0%) were. Of the twenty-six aprons, which have been used since 2005, eleven (42.3%) were damaged. Of the ten aprons, which have been used since 2008, none (0%) was damaged. Of the twenty-three aprons that have been used since 2009, two (8.7%) of them were damaged. Of the eight aprons used since 2010, one (12.3%) was damaged. Of the four aprons used since 2011, none (0%) of them were damaged. The most common site of damage to the radiation-protective shields was at the waist of the aprons (51%). Conclusions: As a result, aprons that have been used for a long period of time can have a higher risk of damage. Radiation-protective shields should be inspected regularly and exchanged for new products for the safety of medical workers.

Keywords

References

  1. Kim TW, Jung JH, Jeon HJ, Yoon KB, Yoon DM. Radiation exposure to physicians during interventional pain procedures. Korean J Pain 2010; 23: 24-27. https://doi.org/10.3344/kjp.2010.23.1.24
  2. Le Heron J, Padovani R, Smith I, Czarwinski R. Radiation protection of medical staff. Eur J Radiol 2010; 76: 20-23. https://doi.org/10.1016/j.ejrad.2010.06.034
  3. Tonnessen BH, Pounds L. Radiation physics. J Vasc Surg 2011; 53: 6S-8S.
  4. Mroz TE, Yamashita T, Davros WJ, Lieberman IH. Radiation exposure to the surgeon and the patient during kyphoplasty. J Spinal Disord Tech 2008; 21: 96-100. https://doi.org/10.1097/BSD.0b013e31805fe9e1
  5. Cousins C, Sharp C. Medical interventional proceduresreducing the radiation risks. Clin Radiol 2004; 59: 468-473. https://doi.org/10.1016/j.crad.2003.11.014
  6. Shope TB. Radiation-induced skin injuries from fluoroscopy. Radiographics 1996; 16: 1195-1199. https://doi.org/10.1148/radiographics.16.5.8888398
  7. Schueler BA. Operator shielding: how and why. Tech Vasc Interv Radiol 2010; 13: 167-171. https://doi.org/10.1053/j.tvir.2010.03.005
  8. Yaffe MJ, Mawdsley GE, Lilley M, Servant R, Reh G. Composite materials for x-ray protection. Health Phys 1991; 60: 661-664. https://doi.org/10.1097/00004032-199105000-00004
  9. Poletti JL, McLean D. The effect of source to image-receptor distance on effective dose for some common X-ray projections. Br J Radiol 2005; 78: 810-815. https://doi.org/10.1259/bjr/74823655
  10. Botwin KP, Freeman ED, Gruber RD, Torres-Rames FM, Bouchtas CG, Sanelli JT, et al. Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections. Pain Physician 2001; 4: 343-348.
  11. Hellawell GO, Mutch SJ, Thevendran G, Wells E, Morgan RJ. Radiation exposure and the urologist: what are the risks? J Urol 2005; 174: 948-952. https://doi.org/10.1097/01.ju.0000170232.58930.8f
  12. Manchikanti L, Cash KA, Moss TL, Pampati V. Radiation exposure to the physician in interventional pain management. Pain Physician 2002; 5: 385-393.
  13. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007; 37: 1-332.
  14. Miller DL, Vañó E, Bartal G, Balter S, Dixon R, Padovani R, et al. Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. J Vasc Interv Radiol 2010; 21: 607-615. https://doi.org/10.1016/j.jvir.2010.01.007
  15. Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 2005; 13: 69-76. https://doi.org/10.5435/00124635-200501000-00009
  16. Powys R, Robinson J, Kench PL, Ryan J, Brennan PC. Strict X-ray beam collimation for facial bones examination can increase lens exposure. Br J Radiol 2012; 85: e497-e505. https://doi.org/10.1259/bjr/19989149
  17. Cho JH, Kim JY, Kang JE, Park PE, Kim JH, Lim JA, et al. A study to compare the radiation absorbed dose of the C-arm fluoroscopic modes. Korean J Pain 2011; 24: 199-204. https://doi.org/10.3344/kjp.2011.24.4.199
  18. Park PE, Park JM, Kang JE, Cho JH, Cho SJ, Kim JH, et al. Radiation safety and education in the applicants of the final test for the expert of pain medicine. Korean J Pain 2012; 25: 16-21. https://doi.org/10.3344/kjp.2012.25.1.16

Cited by

  1. Radiation Safety for Pain Physicians: Technique or Equipment vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.101
  2. How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions? vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.145
  3. The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions vol.27, pp.2, 2014, https://doi.org/10.3344/kjp.2014.27.2.162
  4. The radiation safety education and the pain physicians' efforts to reduce radiation exposure vol.30, pp.2, 2017, https://doi.org/10.3344/kjp.2017.30.2.104
  5. Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management vol.31, pp.4, 2018, https://doi.org/10.3344/kjp.2018.31.4.244
  6. Three principles for radiation safety: time, distance, and shielding vol.31, pp.3, 2018, https://doi.org/10.3344/kjp.2018.31.3.145
  7. Radiation exposure and protection for eyes in pain management vol.12, pp.4, 2013, https://doi.org/10.17085/apm.2017.12.4.297