Abstract
CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but due to the larger size than the through diaphragm, it has poorer constructability and cooperation with building equipment. The building structure has a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragmwas placed at the lower connection to avoid obstruction of the building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.
CFT구조의 기둥-보 접합부는 강관의 국부좌굴을 방지하기위해 다이아프램이 필요하다. 외측다이아프램 형식은 관통다이아프램 형식보다 콘크리트의 충전성이 좋으나 시공성과 건축설비와 공조하는 측면에서 불편함이 있다. CFT구조 접합부의 상부 다이아프램은 외측다이아프램 형식으로 하고 하부 다이아프램은 관통다이아프램 형식으로 하였다. 이것은 건축물에서 바닥슬래브가 있으므로 상부 다이아프램은 바닥슬래브와 일체가 되고 하부 다이아프램으로 관통다이아프램을 적용하여 건축설비와의 마찰을 피하고자 한 것이다. 결과적으로 충전성을 개선시킨 CFT구조의 구조성능은 상, 하부 모두 관통다이아프램을 적용한 구조와 비교하면 동일하다는 것을 알 수 있다.