Abstract
In this study, experimental research was carried out to evaluate and improve the seismic performance of high strength R/C interior beam-column joints regions using advanced reinforcing detailings and high ductile fiber-reinforced mortar. Five specimens of retrofitted the beam-column joint regions using advanced reinforcing detailings and high ductile fiber-reinforced mortar were constructed and tested for their retrofitring performances. Specimens designed by retrofitting the interior beam-column joint regions (IJIR series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity. Specimens of IJIR series, designed by the retrofitting of advanced reinforcing detailings and high ductile fiber-reinforced mortar in reinforecd beam-column joint regions increased its maximum load carrying capacity by 114.2~123.5% and its energy dissipation capacity by 1.55~1.85 times in comparison with the standard specimen of SIJC with a displacement ductility of 5.
이 연구에서는 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능을 개선하기 위하여 보-기둥 접합부 영역을 고성능 배근상세 및 고인성섬유 복합 모르타르를 사용하여 보강하고 내진성능을 평가하였다. 총 5개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 이 연구의 실험 결과를 근거로 다음과 같은 결론을 얻었다. 기존 고강도 철근콘크리트 내부 보-기둥 접합부의 위험단면 영역을 고성능 배근상세 및 고인성섬유 복합 모르타르로 보강한 결과 재하 전 과정을 통하여 안정적인 파괴형태 및 내력을 나타내었다. 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능을 개선하기 위하여 고성능 배근상세 및 고인성섬유 복합 모르타르를 사용하여 보강한 실험체(IJIR, IJIRS, IJIRP)는 재하 전 과정을 통하여 안정적인 이력거동을 나타내었고, 최대내력이 표준실험체의 114.2~123.5%, 에너지소산능력은 1.55~1.85배로 표준실험체에 비하여 매우 향상되었다.