DOI QR코드

DOI QR Code

Design optimization of the outlet holes for bone crystal growing with bioactive materials in dental implants: Part I. cross-sectional area

  • Lee, Yong Keun (Graduate School of NID Fusion Technology, Seoul National University of Science and Technology) ;
  • Lee, Kangsoo (Department of Advanced Materials Engineering, Kyonggi University)
  • 투고 : 2013.01.21
  • 심사 : 2013.03.15
  • 발행 : 2013.04.30

초록

In order to improve osseo-integration of a dental implant with bone crystal we studied an implant with holes inside its body to deliver bioactive materials based on a proposed patent. After bioactive material is absorbed, bone crystal can grow into holes to increase implant bonding in addition to surface integration. The larger cross section area of outlet holes showed the less values of the maximum stress, and the stress concentrations near the uppermost outlet holes were also reduced with an increasing number of outlet holes. The conclusion, that the uppermost outlet design improvement was most effective to reduce the stress concentration and improve the growth rate of bone crystal, could be drawn. After the design optimizations, Type 6-C had provided the best results in this study. The overall shape optimization studies on the shape, location, number, and so on, of the outlet holes, should be carried out further.

키워드

참고문헌

  1. P.I. Branemark, "Osseointegration and its experimental background", J. Prosthet. Dent. 50 (1983) 399. https://doi.org/10.1016/S0022-3913(83)80101-2
  2. L.A. Weinberg and B. Kruger, "Biomechanical considerations when combining tooth-supported and implantsupported prostheses", Oral Surg. Oral Med. Oral Pathol. 78 (1994) 22. https://doi.org/10.1016/0030-4220(94)90112-0
  3. D.C. Holmes, W.R. Grigsby, V.K. Goel and J. C. Keller, "Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis", Int. J. Oral Maxillofac. Implants 7 (1992) 450.
  4. B. Rangert, T. Jemt and L. Jorneus, "Forces and moments on Branemark implants", Int. J. Oral Maxillofac. Implants 4 (1989) 241.
  5. S. Bertazzo and C.A. Bertran, "Morphological and dimensional characteristics of bone mineral crystals", Bioceramics 18 (2006) 7.
  6. M. Quirynen, N. Van Assche, D. Botticelli and T. Berglundh, "How does the timing of implant placement to extraction affect outcome?" Int. J. Oral Maxillofac. Implants 22 Suppl. (2007) 203.
  7. R. Crespi, P. Cappare, E. Gherlone and G.E. Romanos, "Immediate versus delayed loading of dental implants placed in fresh extraction sockets in the maxillary esthetic zone: a clinical comparative study", Int. J. Oral Maxillofac. Implants 23 (2008) 753.
  8. R. Palmer, "Ti-unite dental implant surface may be superior to machined surface in replacement of failed implants", J. Evid. Base. Dent. Pract. 7 (2007) 8. https://doi.org/10.1016/j.jebdp.2006.12.001
  9. J.K. Lee, Y.H. Ko and N.H. Lee, "Biocompatibility of porous hydroxyapatite ceramics prepared from bovine bones", J. Kor. Cryst. Growth Cryst. Tech. 22 (2012) 139. https://doi.org/10.6111/JKCGCT.2012.22.3.139
  10. S.J. Lim, H.Y. Shin, J.H. Kim and J.I. Lim, "Finite element analysis for czochralski growth process of sapphire single crystal", J. Kor. Cryst. Growth Cryst. Tech. 21 (2011) 193. https://doi.org/10.6111/JKCGCT.2011.21.5.193